Skip to content

v3.1.2

Compare
Choose a tag to compare
@Acuminator-Sync Acuminator-Sync released this 21 Jul 14:40
· 60 commits to master since this release

Acuminator 3.1.2: June 8, 2023

Acuminator 3.1.2 includes the bug fixes and enhancements described in this section, as well as the features that have been implemented in previous versions.

Enhancements

In Acuminator 3.1.2, the following enhancements have been implemented:

  • The PX1096 diagnostic has been added to check the signature of methods with the PXOverride attribute: The diagnostic checks whether the base graph or base graph extensions contain a base method that is compatible with the PXOverride method.
  • The PX1007 diagnostic has been updated in the following ways:
    • The diagnostic now supports the inheritdoc tag for DACs, DAC extensions, and their properties. The diagnostic also checks that mapped DAC field properties of projection DACs have the inheritdoc tag with the cref attribute pointing to the corresponding DAC field property of the original DAC.
    • A new code fix can generate the inheritdoc tag for a mapped DAC property of a projection DAC.
      This code fix also removes incorrect documentation tags such as summary or incorrectly declared inheritdoc.
    • Code fixes of the diagnostic can now generate documentation correctly even for badly formatted code. Also, in the properties of mapped fields of projection DACs, incorrect documentation tags can be removed. The code fixes also support documentation tags declared as empty XML elements, such as <summary/>.
    • The diagnostic no longer checks the following DAC fields for a code annotation:
      • Selected
      • Attributes
      • GroupMask
      • CompanyID
      • CompanyMask
      • DeletedDatabaseRecord
    • The Suppress with a local comment code fix of Acuminator now supports the Fix All functionality of Visual Studio for the PX1007 diagnostic. The diagnostic can be suppressed for a whole DAC. Suppressing the diagnostic could be useful when you do not plan to write the documentation immediately and want to leave it to the documentation team.

Fixed Bugs

In this version of Acuminator, the following bugs have been fixed:

  • In Visual Studio 2022, Acuminator analysis did not work in the out-of-process mode (that is, when the Run code analysis in separate process check box is selected in Visual Studio options).
  • The PX1023 diagnostic showed a false alert for the INUnit attribute.
  • It was possible to suppress the PX1007 diagnostic for DAC extensions by marking the class with the PXHidden attribute.
  • The PX1016 diagnostic showed a false alert for generic non-abstract graph extensions.