Original file line number Diff line number Diff line change
Expand Up @@ -447,25 +447,30 @@
//#define TEMP_SENSOR_1_AS_REDUNDANT
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10

#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target

#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target

#define TEMP_CHAMBER_RESIDENCY_TIME 10 // (seconds) Time to wait for chamber to "settle" in M191
#define TEMP_CHAMBER_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target

// Below this temperature the heater will be switched off
// because it probably indicates a broken thermistor wire.
#define HEATER_0_MINTEMP 0
#define HEATER_0_MINTEMP 5
#define HEATER_1_MINTEMP 5
#define HEATER_2_MINTEMP 5
#define HEATER_3_MINTEMP 5
#define HEATER_4_MINTEMP 5
#define HEATER_5_MINTEMP 5
#define HEATER_6_MINTEMP 5
#define HEATER_7_MINTEMP 5
#define BED_MINTEMP 0
#define BED_MINTEMP 5
#define CHAMBER_MINTEMP 5

// Above this temperature the heater will be switched off.
// This can protect components from overheating, but NOT from shorts and failures.
Expand All @@ -479,9 +484,10 @@
#define HEATER_6_MAXTEMP 275
#define HEATER_7_MAXTEMP 275
#define BED_MAXTEMP 120
#define CHAMBER_MAXTEMP 60

/**
* Thermal Overshoot
* Thermal Overshoot (CF)
* During heatup (and printing) the temperature can often "overshoot" the target by many degrees
* (especially before PID tuning). Setting the target temperature too close to MAXTEMP guarantees
* a MAXTEMP shutdown! Use these values to forbid temperatures being set too close to MAXTEMP.
Expand Down Expand Up @@ -562,7 +568,51 @@
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
#endif // PIDTEMPBED

#if EITHER(PIDTEMP, PIDTEMPBED)
//===========================================================================
//==================== PID > Chamber Temperature Control ====================
//===========================================================================

/**
* PID Chamber Heating
*
* If this option is enabled set PID constants below.
* If this option is disabled, bang-bang will be used and CHAMBER_LIMIT_SWITCHING will enable
* hysteresis.
*
* The PID frequency will be the same as the extruder PWM.
* If PID_dT is the default, and correct for the hardware/configuration, that means 7.689Hz,
* which is fine for driving a square wave into a resistive load and does not significantly
* impact FET heating. This also works fine on a Fotek SSR-10DA Solid State Relay into a 200W
* heater. If your configuration is significantly different than this and you don't understand
* the issues involved, don't use chamber PID until someone else verifies that your hardware works.
*/
//#define PIDTEMPCHAMBER
//#define CHAMBER_LIMIT_SWITCHING

/**
* Max Chamber Power
* Applies to all forms of chamber control (PID, bang-bang, and bang-bang with hysteresis).
* When set to any value below 255, enables a form of PWM to the chamber heater that acts like a divider
* so don't use it unless you are OK with PWM on your heater. (See the comment on enabling PIDTEMPCHAMBER)
*/
#define MAX_CHAMBER_POWER 255 // limits duty cycle to chamber heater; 255=full current

#if ENABLED(PIDTEMPCHAMBER)
#define MIN_CHAMBER_POWER 0
//#define PID_CHAMBER_DEBUG // Sends debug data to the serial port.

// Lasko "MyHeat Personal Heater" (200w) modified with a Fotek SSR-10DA to control only the heating element
// and placed inside the small Creality printer enclosure tent.
//
#define DEFAULT_chamberKp 37.04
#define DEFAULT_chamberKi 1.40
#define DEFAULT_chamberKd 655.17
// M309 P37.04 I1.04 D655.17

// FIND YOUR OWN: "M303 E-2 C8 S50" to run autotune on the chamber at 50 degreesC for 8 cycles.
#endif // PIDTEMPCHAMBER

#if ANY(PIDTEMP, PIDTEMPBED, PIDTEMPCHAMBER)
//#define PID_DEBUG // Sends debug data to the serial port. Use 'M303 D' to toggle activation.
//#define PID_OPENLOOP // Puts PID in open loop. M104/M140 sets the output power from 0 to PID_MAX
//#define SLOW_PWM_HEATERS // PWM with very low frequency (roughly 0.125Hz=8s) and minimum state time of approximately 1s useful for heaters driven by a relay
Expand Down Expand Up @@ -919,11 +969,6 @@
*/
//#define BLTOUCH

/**
* Pressure sensor with a BLTouch-like interface
*/
//#define CREALITY_TOUCH

/**
* Touch-MI Probe by hotends.fr
*
Expand Down
7 changes: 7 additions & 0 deletions Marlin/Configuration_adv.h
Original file line number Diff line number Diff line change
Expand Up @@ -149,6 +149,13 @@
//
// Heated Chamber options
//
#if DISABLED(PIDTEMPCHAMBER)
#define CHAMBER_CHECK_INTERVAL 5000 // (ms) Interval between checks in bang-bang control
#if ENABLED(CHAMBER_LIMIT_SWITCHING)
#define CHAMBER_HYSTERESIS 2 // (°C) Only set the relevant heater state when ABS(T-target) > CHAMBER_HYSTERESIS
#endif
#endif

#if TEMP_SENSOR_CHAMBER
#define CHAMBER_MINTEMP 5
#define CHAMBER_MAXTEMP 60
Expand Down
67 changes: 61 additions & 6 deletions config/btt-skr-cr6-with-btt-tft-biqu-h2/Configuration.h
Original file line number Diff line number Diff line change
Expand Up @@ -457,6 +457,10 @@
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target

#define TEMP_CHAMBER_RESIDENCY_TIME 10 // (seconds) Time to wait for chamber to "settle" in M191
#define TEMP_CHAMBER_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target

// Below this temperature the heater will be switched off
// because it probably indicates a broken thermistor wire.
#define HEATER_0_MINTEMP 5
Expand All @@ -468,6 +472,7 @@
#define HEATER_6_MINTEMP 5
#define HEATER_7_MINTEMP 5
#define BED_MINTEMP 5
#define CHAMBER_MINTEMP 5

// Above this temperature the heater will be switched off.
// This can protect components from overheating, but NOT from shorts and failures.
Expand All @@ -481,6 +486,17 @@
#define HEATER_6_MAXTEMP 275
#define HEATER_7_MAXTEMP 275
#define BED_MAXTEMP 120
#define CHAMBER_MAXTEMP 60

/**
* Thermal Overshoot (CF)
* During heatup (and printing) the temperature can often "overshoot" the target by many degrees
* (especially before PID tuning). Setting the target temperature too close to MAXTEMP guarantees
* a MAXTEMP shutdown! Use these values to forbid temperatures being set too close to MAXTEMP.
*/
#define HOTEND_OVERSHOOT 15 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
#define BED_OVERSHOOT 10 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
#define COOLER_OVERSHOOT 2 // (°C) Forbid temperatures closer than OVERSHOOT

//===========================================================================
//============================= PID Settings ================================
Expand Down Expand Up @@ -554,7 +570,51 @@
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
#endif // PIDTEMPBED

#if EITHER(PIDTEMP, PIDTEMPBED)
//===========================================================================
//==================== PID > Chamber Temperature Control ====================
//===========================================================================

/**
* PID Chamber Heating
*
* If this option is enabled set PID constants below.
* If this option is disabled, bang-bang will be used and CHAMBER_LIMIT_SWITCHING will enable
* hysteresis.
*
* The PID frequency will be the same as the extruder PWM.
* If PID_dT is the default, and correct for the hardware/configuration, that means 7.689Hz,
* which is fine for driving a square wave into a resistive load and does not significantly
* impact FET heating. This also works fine on a Fotek SSR-10DA Solid State Relay into a 200W
* heater. If your configuration is significantly different than this and you don't understand
* the issues involved, don't use chamber PID until someone else verifies that your hardware works.
*/
//#define PIDTEMPCHAMBER
//#define CHAMBER_LIMIT_SWITCHING

/**
* Max Chamber Power
* Applies to all forms of chamber control (PID, bang-bang, and bang-bang with hysteresis).
* When set to any value below 255, enables a form of PWM to the chamber heater that acts like a divider
* so don't use it unless you are OK with PWM on your heater. (See the comment on enabling PIDTEMPCHAMBER)
*/
#define MAX_CHAMBER_POWER 255 // limits duty cycle to chamber heater; 255=full current

#if ENABLED(PIDTEMPCHAMBER)
#define MIN_CHAMBER_POWER 0
//#define PID_CHAMBER_DEBUG // Sends debug data to the serial port.

// Lasko "MyHeat Personal Heater" (200w) modified with a Fotek SSR-10DA to control only the heating element
// and placed inside the small Creality printer enclosure tent.
//
#define DEFAULT_chamberKp 37.04
#define DEFAULT_chamberKi 1.40
#define DEFAULT_chamberKd 655.17
// M309 P37.04 I1.04 D655.17

// FIND YOUR OWN: "M303 E-2 C8 S50" to run autotune on the chamber at 50 degreesC for 8 cycles.
#endif // PIDTEMPCHAMBER

#if ANY(PIDTEMP, PIDTEMPBED, PIDTEMPCHAMBER)
//#define PID_DEBUG // Sends debug data to the serial port. Use 'M303 D' to toggle activation.
//#define PID_OPENLOOP // Puts PID in open loop. M104/M140 sets the output power from 0 to PID_MAX
//#define SLOW_PWM_HEATERS // PWM with very low frequency (roughly 0.125Hz=8s) and minimum state time of approximately 1s useful for heaters driven by a relay
Expand Down Expand Up @@ -910,11 +970,6 @@
*/
//#define BLTOUCH

/**
* Pressure sensor with a BLTouch-like interface
*/
//#define CREALITY_TOUCH

/**
* Touch-MI Probe by hotends.fr
*
Expand Down
7 changes: 7 additions & 0 deletions config/btt-skr-cr6-with-btt-tft-biqu-h2/Configuration_adv.h
Original file line number Diff line number Diff line change
Expand Up @@ -137,6 +137,13 @@
//
// Heated Chamber options
//
#if DISABLED(PIDTEMPCHAMBER)
#define CHAMBER_CHECK_INTERVAL 5000 // (ms) Interval between checks in bang-bang control
#if ENABLED(CHAMBER_LIMIT_SWITCHING)
#define CHAMBER_HYSTERESIS 2 // (°C) Only set the relevant heater state when ABS(T-target) > CHAMBER_HYSTERESIS
#endif
#endif

#if TEMP_SENSOR_CHAMBER
#define CHAMBER_MINTEMP 5
#define CHAMBER_MAXTEMP 60
Expand Down
67 changes: 61 additions & 6 deletions config/btt-skr-cr6-with-btt-tft-e3d-hemera/Configuration.h
Original file line number Diff line number Diff line change
Expand Up @@ -457,6 +457,10 @@
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target

#define TEMP_CHAMBER_RESIDENCY_TIME 10 // (seconds) Time to wait for chamber to "settle" in M191
#define TEMP_CHAMBER_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target

// Below this temperature the heater will be switched off
// because it probably indicates a broken thermistor wire.
#define HEATER_0_MINTEMP 5
Expand All @@ -468,6 +472,7 @@
#define HEATER_6_MINTEMP 5
#define HEATER_7_MINTEMP 5
#define BED_MINTEMP 5
#define CHAMBER_MINTEMP 5

// Above this temperature the heater will be switched off.
// This can protect components from overheating, but NOT from shorts and failures.
Expand All @@ -481,6 +486,17 @@
#define HEATER_6_MAXTEMP 275
#define HEATER_7_MAXTEMP 275
#define BED_MAXTEMP 120
#define CHAMBER_MAXTEMP 60

/**
* Thermal Overshoot (CF)
* During heatup (and printing) the temperature can often "overshoot" the target by many degrees
* (especially before PID tuning). Setting the target temperature too close to MAXTEMP guarantees
* a MAXTEMP shutdown! Use these values to forbid temperatures being set too close to MAXTEMP.
*/
#define HOTEND_OVERSHOOT 15 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
#define BED_OVERSHOOT 10 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
#define COOLER_OVERSHOOT 2 // (°C) Forbid temperatures closer than OVERSHOOT

//===========================================================================
//============================= PID Settings ================================
Expand Down Expand Up @@ -554,7 +570,51 @@
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
#endif // PIDTEMPBED

#if EITHER(PIDTEMP, PIDTEMPBED)
//===========================================================================
//==================== PID > Chamber Temperature Control ====================
//===========================================================================

/**
* PID Chamber Heating
*
* If this option is enabled set PID constants below.
* If this option is disabled, bang-bang will be used and CHAMBER_LIMIT_SWITCHING will enable
* hysteresis.
*
* The PID frequency will be the same as the extruder PWM.
* If PID_dT is the default, and correct for the hardware/configuration, that means 7.689Hz,
* which is fine for driving a square wave into a resistive load and does not significantly
* impact FET heating. This also works fine on a Fotek SSR-10DA Solid State Relay into a 200W
* heater. If your configuration is significantly different than this and you don't understand
* the issues involved, don't use chamber PID until someone else verifies that your hardware works.
*/
//#define PIDTEMPCHAMBER
//#define CHAMBER_LIMIT_SWITCHING

/**
* Max Chamber Power
* Applies to all forms of chamber control (PID, bang-bang, and bang-bang with hysteresis).
* When set to any value below 255, enables a form of PWM to the chamber heater that acts like a divider
* so don't use it unless you are OK with PWM on your heater. (See the comment on enabling PIDTEMPCHAMBER)
*/
#define MAX_CHAMBER_POWER 255 // limits duty cycle to chamber heater; 255=full current

#if ENABLED(PIDTEMPCHAMBER)
#define MIN_CHAMBER_POWER 0
//#define PID_CHAMBER_DEBUG // Sends debug data to the serial port.

// Lasko "MyHeat Personal Heater" (200w) modified with a Fotek SSR-10DA to control only the heating element
// and placed inside the small Creality printer enclosure tent.
//
#define DEFAULT_chamberKp 37.04
#define DEFAULT_chamberKi 1.40
#define DEFAULT_chamberKd 655.17
// M309 P37.04 I1.04 D655.17

// FIND YOUR OWN: "M303 E-2 C8 S50" to run autotune on the chamber at 50 degreesC for 8 cycles.
#endif // PIDTEMPCHAMBER

#if ANY(PIDTEMP, PIDTEMPBED, PIDTEMPCHAMBER)
//#define PID_DEBUG // Sends debug data to the serial port. Use 'M303 D' to toggle activation.
//#define PID_OPENLOOP // Puts PID in open loop. M104/M140 sets the output power from 0 to PID_MAX
//#define SLOW_PWM_HEATERS // PWM with very low frequency (roughly 0.125Hz=8s) and minimum state time of approximately 1s useful for heaters driven by a relay
Expand Down Expand Up @@ -910,11 +970,6 @@
*/
//#define BLTOUCH

/**
* Pressure sensor with a BLTouch-like interface
*/
//#define CREALITY_TOUCH

/**
* Touch-MI Probe by hotends.fr
*
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -137,6 +137,13 @@
//
// Heated Chamber options
//
#if DISABLED(PIDTEMPCHAMBER)
#define CHAMBER_CHECK_INTERVAL 5000 // (ms) Interval between checks in bang-bang control
#if ENABLED(CHAMBER_LIMIT_SWITCHING)
#define CHAMBER_HYSTERESIS 2 // (°C) Only set the relevant heater state when ABS(T-target) > CHAMBER_HYSTERESIS
#endif
#endif

#if TEMP_SENSOR_CHAMBER
#define CHAMBER_MINTEMP 5
#define CHAMBER_MAXTEMP 60
Expand Down