CASMCMS-9078: Document BOS automatically tagging SBPS images
Browse files Browse the repository at this point in the history
Describe how BOS automatically tags an image with `sbps-project: true`
if the Scalable Boot Provisioning Service (SBPS) provides the root
file system.
  • Loading branch information
jsollom-hpe committed Oct 2, 2024
1 parent f2adcb4 commit 9a4b4e6
Showing 1 changed file with 7 additions and 3 deletions.
10 changes: 7 additions & 3 deletions operations/boot_orchestration/BOS_Workflows.md
Original file line number Diff line number Diff line change
Expand Up @@ -106,7 +106,9 @@ The following workflows are included in this section:

1. **Power-on operator**

The power-on operator will detect nodes with a `power-on-pending` status. The power-on operator first sets the desired boot artifacts in BSS.
The power-on operator will detect nodes with a `power-on-pending` status. If root file system provider is the Scalable Boot Provisioning Service (`SBPS`), then the power-on operator
will notify SBPS that the root file system needs to be projected. It will do this by tagging the image with `sbps-project: true` using the Image Management Service (IMS).
Then, the power-on operator sets the desired boot artifacts in BSS.
If configuration is enabled for the node, the power-on operator will also call CFS to set the desired configuration and disable the node with CFS.
The node must be disabled within CFS so that CFS does not try to configure node until it has booted.
The power-on operator then calls PCS to power-on the node.
Expand All @@ -127,7 +129,7 @@ The following workflows are included in this section:

1. **Status operator (configuring)**

The status operator monitors a node's power state until HSM reports that the power state is on.
The status operator monitors a node's power state until HSM reports that the power state is on.
When the power state for a node is on, the status operator will either set the phase to `configuring` if CFS configuration is required or it will clear the current phase
if the node is in its final state.
Expand Down Expand Up @@ -236,7 +238,9 @@ The following workflows are included in this section:

1. **Power-on operator**

The power-on operator will detect nodes with a `power-on-pending` status. The power-on operator first sets the desired boot artifacts in BSS.
The power-on operator will detect nodes with a `power-on-pending` status. If root file system provider is the Scalable Boot Provisioning Service (`SBPS`), then the power-on operator
will notify SBPS that the root file system needs to be projected. It will do this by tagging the image with `sbps-project: true` using the Image Management Service (IMS).
Then, the power-on operator sets the desired boot artifacts in BSS.
If configuration is enabled for the node, the power-on operator will also call CFS to set the desired configuration and disable the node with CFS.
The node must be disabled within CFS so that CFS does not try to configure node until it has booted.
The power-on operator then calls PCS to power-on the node.
Expand Down