Version 3.1 (and some 3.3) - Plug or Switch Type

DP ID Function Point Type Range Units
1 Switch bool True/False
2 Countdown? integer 0-86400 s
4 Current integer 0-30000 mA
5 Power integer 0-50000 W
6 Voltage integer 0-5000 V

Caution

Version 3.1 - Light Type (RGB)

DP ID Function Point Type Range Units
1 Switch bool True/False
2 Mode enum white, colour, scene, music
3 Bright integer 10-1000*
4 Color Temp integer 0-1000*
5 Color hexstring r:0-255, g:0-255, b:0-255, h:0-360, s:0-255, v:0-255 rgb+hsv

Caution

Version 3.3 Devices

Version 3.3 - Plug, Switch, Power Strip Type

DP ID Function Point Type Range Units
1 Switch 1 bool True/False
2 Switch 2 bool True/False
3 Switch 3 bool True/False
4 Switch 4 bool True/False
5 Switch 5 bool True/False
6 Switch 6 bool True/False
7 Switch 7/usb bool True/False
9 Countdown 1 integer 0-86400 s
10 Countdown 2 integer 0-86400 s
11 Countdown 3 integer 0-86400 s
12 Countdown 4 integer 0-86400 s
13 Countdown 5 integer 0-86400 s
14 Countdown 6 integer 0-86400 s
15 Countdown 7 integer 0-86400 s
17 Add Electricity integer 0-50000 kWh
18 Current integer 0-30000 mA
19 Power integer 0-50000 W
20 Voltage integer 0-5000 V
21 Test Bit integer 0-5 n/a
22 Voltage coeff. integer 0-1000000
23 Current coeff. integer 0-1000000
24 Power coeff. integer 0-1000000
25 Electricity coeff. integer 0-1000000
26 Fault fault ov_cr
38 Power-on state setting enum off, on, memory
39 Overcharge Switch bool True/False
40 Indicator status setting enum none, on, relay, pos
41 Child Lock bool True/False
42 UNKNOWN
43 UNKNOWN
44 UNKNOWN

Note

Note: Some 3.3 energy management plugs use the DPS values of the 3.1 plug above.


Caution

Version 3.3 - Dimmer Switch

DP ID Function Point Type Range Units
1 Switch bool True/False
2 Brightness integer 10-1000*
3 Minimum of Brightness integer 10-1000*
4 Type of light source1 enum LED, incandescent, halogen
5 Mode enum white

Caution

Version 3.3 - Light Type (RGB)

DP ID Function Point Type Range Units
20 Switch bool True/False
21 Mode enum white, colour, scene, music
22 Bright integer 10-1000*
23 Color Temp integer 0-1000
24 Color hexstring h:0-360, s:0-1000, v:0-1000 hsv
25 Scene string n/a
26 Left time integer 0-86400 s
27 Music string n/a
28 Debugger string n/a
29 Debug string n/a

Caution

Version 3.3 - Automated Curtain Type

DP ID Function Point Type Range Units
1 Curtain Switch 1 enum open, stop, close, continue
2 Percent control 1 integer 0-100 %
3 Accurate Calibration 1 enum start, end
4 Curtain Switch 2 enum open, stop, close, continue
5 Percent control 2 integer 0-100 %
6 Accurate Calibration 2 enum start, end
8 Motor Steer 1 enum forward, back
9 Motor steer 2 enum forward, back
10 Quick Calibration 1 integer 1-180 s
11 Quick Calibration 2 integer 1-180 s
12 Motor Mode 1 enum strong_power, dry_contact
13 Motor Mode 2 enum strong_power, dry_contact
14 Light mode enum relay, pos, none

Caution

Version 3.3 - Fan Switch Type

DP ID Function Point Type Range Units
1 Fan switch bool True/False n/a
2 Fan countdown integer 0-86400 s
3 Fan speed enum level_1, level_2, level_3, level_4, level_5
4 Fan speed integer 1-100 %
5 Fan light switch bool True/False
6 Brightness integer 10-1000
7 Fan light countdown integer 0-86400 s
8 Minimum brightness integer 10-1000
9 Maximum brightness integer 10-1000
10 Mode enum white
11 Power-on state setting enum off, on, memory
12 Indicator status setting enum none, relay, pos
13 Backlight switch bool True/False

Caution

Version 3.3 - Universal IR Controller with optional Temperature/Humidity

DP ID Function Point Type Range Units
101 Current Temperature integer 0-600 10x Celsius
102 Current Humidity integer 0-100 %
201 IR Commands (set only) JSON* n/a n/a