Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

Full Changelog: v1.7...v1.9

v1.8

03 Jul 19:02
Compare
Choose a tag to compare

About

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

Full Changelog: v1.7...v1.8

v1.7

03 Apr 16:27
1dd136f
Compare
Choose a tag to compare

About

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

What's Changed

  • Added parameter p_th_min to add a minimum thermal power output in hplib.sumulate().

Full Changelog: v1.5...v1.7

v1.6

03 Apr 16:01
edd5ceb
Compare
Choose a tag to compare

About

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

What's Changed

  • Added parameter p_th_min to add a minimum thermal power output in hplib.sumulate().

Full Changelog: v1.5...v1.6

v1.5

08 Mar 12:46
4234db8
Compare
Choose a tag to compare

About

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

What's Changed

Full Changelog: v1.4...v1.5

v1.4

08 Mar 09:45
3725a32
Compare
Choose a tag to compare

About

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

What's Changed

  • Added function calc_brine_temp1 by @xihaui in #16
  • Feature heating system temperatures by @ttjaden in #17
  • added versioneer for versioning by @xihaui in #19

Full Changelog: v1.3...v1.4

heat pump library (v1.3)

10 Nov 10:13
5f2f053
Compare
Choose a tag to compare

About

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

What's changed in v.1.3

For speeding up simulations that use hplib in for loops or single time steps iterations a new HeatPump class was introduced including a optimized simulate() method. Further more, the hplib is now also capable of simulate the thermal cooling power and EER for heat pumps of group id 1 (air/water | regulated).

Full Changelog: v1.2...v1.3

heat pump library (v1.2)

06 Oct 18:11
Compare
Choose a tag to compare

What's Changed

Full Changelog: v1.0...v1.2

heat pump library

22 Sep 14:56
Compare
Choose a tag to compare

hplib - heat pump library

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets
  • identify efficiency parameters from the database with a least-square regression model
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

Documentation

If you're interested in how the database and parameters were calclulated, have a look into the Documentation HTML or Jupyter-Notebook. There you also find a simulation examples and a validation.

Usage

Download or clone repository:

git clone https://github.com/RE-Lab-Projects/hplib.git

Create the environment:

conda env create --name hplib --file requirements.txt

Create some code with import hplib and use the included functions load_database, get_parameters and simulate.

Heat pump models and Group IDs

The hplib_database.csv contains the following number of heat pump models, sorted by Group ID

Group 1, Outdoor Air / Water, Regulated (366 Models)
Group 2, Brine / Water, Regulated (54 Models)
Group 3, Water / Water, Regulated (0 Models)
Group 4, Outdoor Air / Water, On-Off (23 Models)
Group 5, Brine / Water, On-Off (53 Models)
Group 6, Water / Water, On-Off (10 Models)

Database

All resulting database CSV file are under License: CC BY 4.0.

The following columns are available for every heat pump of this library

Manufacturer | Name of the manufacturer
Model | Name of the heat pump model
Date | heat pump certification date
Type | Type of heat pump model
Subtype | Subtype of heat pump model
Group ID | ID for combination of type and subtype
Refrigerant | Refrigerant Type
Mass of Refrigerant [kg]| Mass of Refrigerant
SPL indoor [dBA]| Sound emissions indoor
SPL outdoor [dBA]| Sound emissions outdoor
PSB [W] | Eletrical power consumption, standby mode
Climate | Climate definition for set points, which were used for parameter identification |
P_el_ref [W]| Electrical power at -7°C / 52°C
P_th_ref [W]| Thermal power at -7°C / 52°C
p1-p4_P_th | Fit-Parameters for thermal power
p1-p4_P_el | Fit-Parameters for electricl power
p1-p4_COP | Fit-Parameters for COP
MAPE_P_el | mean absolute percentage error for electrical input power (simulation vs. measurement)
MAPE_COP | mean absolute percentage error for thermal input power (simulation vs. measurement)
MAPE_P_th | mean absolute percentage error for coefficient of performance (simulation vs. measurement)

Input-Data and further development

The European Heat Pump Association (EHPA) hosts a website with the results of laboratory measurements from the keymark certification process. For every heat pump model a pdf file can be downloaded from https://keymark.eu/en/products/heatpumps/certified-products.

This repository is based on all pdf files that were download for every manufacturer on 2021-03-12.

heat pump library

22 Sep 14:52
Compare
Choose a tag to compare

hplib - heat pump library

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets
  • identify efficiency parameters from the database with a least-square regression model
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

Documentation

If you're interested in how the database and parameters were calclulated, have a look into the Documentation HTML or Jupyter-Notebook. There you also find a simulation examples and a validation.

Usage

Download or clone repository:

git clone https://github.com/RE-Lab-Projects/hplib.git

Create the environment:

conda env create --name hplib --file requirements.txt

Create some code with import hplib and use the included functions load_database, get_parameters and simulate.

Heat pump models and Group IDs

The hplib_database.csv contains the following number of heat pump models, sorted by Group ID

Group 1, Outdoor Air / Water, Regulated (366 Models)
Group 2, Brine / Water, Regulated (54 Models)
Group 3, Water / Water, Regulated (0 Models)
Group 4, Outdoor Air / Water, On-Off (23 Models)
Group 5, Brine / Water, On-Off (53 Models)
Group 6, Water / Water, On-Off (10 Models)

Database

All resulting database CSV file are under License: CC BY 4.0.

The following columns are available for every heat pump of this library

Manufacturer | Name of the manufacturer
Model | Name of the heat pump model
Date | heat pump certification date
Type | Type of heat pump model
Subtype | Subtype of heat pump model
Group ID | ID for combination of type and subtype
Refrigerant | Refrigerant Type
Mass of Refrigerant [kg]| Mass of Refrigerant
SPL indoor [dBA]| Sound emissions indoor
SPL outdoor [dBA]| Sound emissions outdoor
PSB [W] | Eletrical power consumption, standby mode
Climate | Climate definition for set points, which were used for parameter identification |
P_el_ref [W]| Electrical power at -7°C / 52°C
P_th_ref [W]| Thermal power at -7°C / 52°C
p1-p4_P_th | Fit-Parameters for thermal power
p1-p4_P_el | Fit-Parameters for electricl power
p1-p4_COP | Fit-Parameters for COP
MAPE_P_el | mean absolute percentage error for electrical input power (simulation vs. measurement)
MAPE_COP | mean absolute percentage error for thermal input power (simulation vs. measurement)
MAPE_P_th | mean absolute percentage error for coefficient of performance (simulation vs. measurement)

Input-Data and further development

The European Heat Pump Association (EHPA) hosts a website with the results of laboratory measurements from the keymark certification process. For every heat pump model a pdf file can be downloaded from https://keymark.eu/en/products/heatpumps/certified-products.

This repository is based on all pdf files that were download for every manufacturer on 2021-03-12.