Reorganized the simualate check module.
Browse files Browse the repository at this point in the history
  • Loading branch information
jcyuan2020 committed Feb 26, 2021
1 parent 9c19825 commit 1d49d51
Showing 1 changed file with 30 additions and 26 deletions.
56 changes: 30 additions & 26 deletions src/EnergyPlus/ChillerGasAbsorption.cc
Original file line number Diff line number Diff line change
Expand Up @@ -149,45 +149,49 @@ namespace EnergyPlus::ChillerGasAbsorption {
.NodeNumIn;
// Match inlet node name of calling branch to determine if this call is for heating or cooling
if (compInletNodeNum == this->ChillReturnNodeNum) { // Operate as chiller
// Calculate Node Values
// Calculate Equipment and Update Variables
this->InCoolingMode = RunFlag != 0;
this->initialize(state);
this->calculateChiller(state, CurLoad);
this->updateCoolRecords(CurLoad, RunFlag);
brIdentity = 1;
break;
} else if (compInletNodeNum == this->HeatReturnNodeNum) { // Operate as heater
// Calculate Node Values
// Calculate Equipment and Update Variables
this->InHeatingMode = RunFlag != 0;
this->initialize(state);
this->calculateHeater(state, CurLoad, RunFlag);
this->updateHeatRecords(CurLoad, RunFlag);
brIdentity = 2;
break;
} else if (compInletNodeNum == this->CondReturnNodeNum) { // called from condenser loop
if (this->CDLoopNum > 0) {
PlantUtilities::UpdateChillerComponentCondenserSide(state,
this->CDLoopNum,
this->CDLoopSideNum,
DataPlant::TypeOf_Chiller_DFAbsorption,
this->CondReturnNodeNum,
this->CondSupplyNodeNum,
this->TowerLoad,
this->CondReturnTemp,
this->CondSupplyTemp,
this->CondWaterFlowRate,
FirstHVACIteration);
}
brIdentity = 3;
break;
} else {
brIdentity = 0;
}
}

if (brIdentity == 0) { // Error, nodes do not match
if (brIdentity == 1) {
// Calculate Node Values
// Calculate Equipment and Update Variables
this->InCoolingMode = RunFlag != 0;
this->initialize(state);
this->calculateChiller(state, CurLoad);
this->updateCoolRecords(CurLoad, RunFlag);
} else if(brIdentity == 2) {
// Calculate Node Values
// Calculate Equipment and Update Variables
this->InHeatingMode = RunFlag != 0;
this->initialize(state);
this->calculateHeater(state, CurLoad, RunFlag);
this->updateHeatRecords(CurLoad, RunFlag);
} else if (brIdentity == 3) {
if (this->CDLoopNum > 0) {
PlantUtilities::UpdateChillerComponentCondenserSide(state,
this->CDLoopNum,
this->CDLoopSideNum,
DataPlant::TypeOf_Chiller_DFAbsorption,
this->CondReturnNodeNum,
this->CondSupplyNodeNum,
this->TowerLoad,
this->CondReturnTemp,
this->CondSupplyTemp,
this->CondWaterFlowRate,
FirstHVACIteration);
}
} else {
// Error, nodes do not match
ShowSevereError(state, "Invalid call to Gas Absorber Chiller " + this->Name);
ShowContinueError(state, "Node connections in branch are not consistent with object nodes.");
ShowFatalError(state, "Preceding conditions cause termination.");
Expand Down