Add tolerance for high humidity OA control
Browse files Browse the repository at this point in the history
  • Loading branch information
mjwitte committed Dec 6, 2019
1 parent d978a37 commit e05852f
Show file tree
Hide file tree
Showing 3 changed files with 174 additions and 1 deletion.
1 change: 1 addition & 0 deletions src/EnergyPlus/DataHVACGlobals.hh
Original file line number Diff line number Diff line change
Expand Up @@ -75,6 +75,7 @@ namespace DataHVACGlobals {

// MODULE PARAMETER DEFINITIONS:

Real64 const SmallHumRatDiff(1.0E-7);
extern Real64 const SmallTempDiff;
extern Real64 const SmallMassFlow;
extern Real64 const VerySmallMassFlow;
Expand Down
3 changes: 2 additions & 1 deletion src/EnergyPlus/MixedAir.cc
Original file line number Diff line number Diff line change
Expand Up @@ -4593,7 +4593,8 @@ namespace MixedAir {
if (ZoneSysMoistureDemand(this->HumidistatZoneNum).TotalOutputRequired < 0.0) {
// IF OAController is not allowed to modify air flow during high outdoor humrat condition, then disable modified air flow
// if indoor humrat is less than or equal to outdoor humrat
if (!this->ModifyDuringHighOAMoisture && Node(this->NodeNumofHumidistatZone).HumRat <= this->OAHumRat) {
if (!this->ModifyDuringHighOAMoisture &&
(Node(this->NodeNumofHumidistatZone).HumRat - this->OAHumRat) <= DataHVACGlobals::SmallHumRatDiff) {
HighHumidityOperationFlag = false;
} else {
HighHumidityOperationFlag = true;
Expand Down
171 changes: 171 additions & 0 deletions tst/EnergyPlus/unit/MixedAir.unit.cc
Original file line number Diff line number Diff line change
Expand Up @@ -1522,6 +1522,177 @@ TEST_F(EnergyPlusFixture, MixedAir_MissingHIghRHControlInputTest)
EXPECT_TRUE(compare_err_stream(error_string, true));
}

TEST_F(EnergyPlusFixture, MixedAir_HIghRHControlTest)
{
std::string const idf_objects = delimited_string({
" OutdoorAir:Node,",
" Outside Air Inlet Node 1; !- Name",

" Schedule:Constant,",
" Min OA Sched, !- Name",
" Any Number, !- Schedule Type Limits Name",
" 0.5; !- Value",

" ScheduleTypeLimits,",
" Any Number; !- Name",

" Controller:OutdoorAir,",
" OA Controller 1, !- Name",
" Relief Air Outlet Node 1, !- Relief Air Outlet Node Name",
" VAV Sys 1 Inlet Node, !- Return Air Node Name",
" Mixed Air Node 1, !- Mixed Air Node Name",
" Outside Air Inlet Node 1, !- Actuator Node Name",
" 0.0, !- Minimum Outdoor Air Flow Rate {m3/s}",
" 2.5, !- Maximum Outdoor Air Flow Rate {m3/s}",
" DifferentialDryBulb, !- Economizer Control Type",
" ModulateFlow, !- Economizer Control Action Type",
" , !- Economizer Maximum Limit Dry-Bulb Temperature {C}",
" , !- Economizer Maximum Limit Enthalpy {J/kg}",
" , !- Economizer Maximum Limit Dewpoint Temperature {C}",
" , !- Electronic Enthalpy Limit Curve Name",
" , !- Economizer Minimum Limit Dry-Bulb Temperature {C}",
" NoLockout, !- Lockout Type",
" ProportionalMinimum, !- Minimum Limit Type",
" Min OA Sched, !- Minimum Outdoor Air Schedule Name",
" , !- Minimum Fraction of Outdoor Air Schedule Name",
" , !- Maximum Fraction of Outdoor Air Schedule Name",
" , !- Mechanical Ventilation Controller Name",
" , !- Time of Day Economizer Control Schedule Name",
" Yes, !- High Humidity Control",
" Zone1, !- Humidistat Control Zone Name",
" 0.8, !- High Humidity Outdoor Air Flow Ratio",
" Yes; !- Control High Indoor Humidity Based on Outdoor Humidity Ratio",
});

ASSERT_TRUE(process_idf(idf_objects));

compare_err_stream(""); // just for debugging

bool ErrorsFound(false); // If errors detected in input
int ControllerNum(0); // Controller number
int NumArg(0);
int NumNums(0);
int NumAlphas(0);
int IOStat(0);
std::string const CurrentModuleObject = CurrentModuleObjects(CMO_OAController);

inputProcessor->getObjectDefMaxArgs(CurrentModuleObjects(CMO_OAController), NumArg, NumAlphas, NumNums);

Array1D<Real64> NumArray(NumNums, 0.0);
Array1D_string AlphArray(NumAlphas);
Array1D_string cAlphaFields(NumAlphas);
Array1D_string cNumericFields(NumNums);
Array1D_bool lAlphaBlanks(NumAlphas, true);
Array1D_bool lNumericBlanks(NumNums, true);

NumOAControllers = inputProcessor->getNumObjectsFound(CurrentModuleObject);
OAController.allocate(NumOAControllers);

ControllerNum = 1;
Zone.allocate(1);
Zone(1).Name = "ZONE1";
NumOfZones = 1;
ZoneEquipConfig.allocate(1);
ZoneEquipConfig(1).ActualZoneNum = 1;
ZoneEquipConfig(1).ZoneNode = 2;
ZoneEquipConfig(1).NumInletNodes = 1;
ZoneEquipConfig(1).InletNodeAirLoopNum.allocate(1);
ZoneEquipConfig(1).InletNodeAirLoopNum(1) = 1;
PrimaryAirSystem.allocate(1);
AirLoopControlInfo.allocate(1);
PrimaryAirSystem(1).NumBranches = 1;
PrimaryAirSystem(1).Branch.allocate(1);
PrimaryAirSystem(1).Branch(1).Comp.allocate(1);
PrimaryAirSystem(1).Branch(1).TotalComponents = 1;
PrimaryAirSystem(1).Branch(1).Comp(1).Name = "OASysName";
PrimaryAirSystem(1).Branch(1).Comp(1).TypeOf = "AirLoopHVAC:OutdoorAirSystem";
OutsideAirSys.allocate(1);
OutsideAirSys(1).Name = "OASysName";
OutsideAirSys(1).NumControllers = 1;
OutsideAirSys(1).ControllerType.allocate(1);
OutsideAirSys(1).ControllerType(1) = "Controller:OutdoorAir";
OutsideAirSys(1).ControllerName.allocate(1);
OutsideAirSys(1).ControllerName(1) = "OA Controller 1";
DataAirLoop::NumOASystems = 1;
HumidityControlZone.allocate(1);
HumidityControlZone(1).ActualZoneNum = 1;
NumHumidityControlZones = 1;

inputProcessor->getObjectItem(CurrentModuleObject,
ControllerNum,
AlphArray,
NumAlphas,
NumArray,
NumNums,
IOStat,
lNumericBlanks,
lAlphaBlanks,
cAlphaFields,
cNumericFields);

ProcessOAControllerInputs(CurrentModuleObject,
ControllerNum,
AlphArray,
NumAlphas,
NumArray,
NumNums,
lNumericBlanks,
lAlphaBlanks,
cAlphaFields,
cNumericFields,
ErrorsFound);
// compare_err_stream( "" ); // just for debugging

EXPECT_FALSE(ErrorsFound);
EXPECT_FALSE(OAController(ControllerNum)
.ModifyDuringHighOAMoisture); // "Control High Indoor Humidity Based on Outdoor Humidity Ratio = Yes" sets this to false
EXPECT_FALSE(has_err_output(true));
EXPECT_EQ(OAController(ControllerNum).HumidistatZoneNum, 1);

// Set up conditions
DataZoneEnergyDemands::ZoneSysMoistureDemand.allocate(1);
DataZoneEnergyDemands::ZoneSysMoistureDemand(1).TotalOutputRequired = -1.0; // dehumidification requested by humidistat
EXPECT_EQ(OAController(ControllerNum).NodeNumofHumidistatZone, ZoneEquipConfig(1).ZoneNode);
int airLoopNum = 1;
int outAirMinFrac = 0.0;
Real64 OASignal = 0.0;
bool HighHumidityOperationFlag = false;
bool firstHVACIteration = false;
OAController(ControllerNum).MixSetTemp = 15.0;
OAController(ControllerNum).RetTemp = 20.0;
OAController(ControllerNum).InletTemp = 25.0;
OAController(ControllerNum).MixMassFlow = 2.5;
OAController(ControllerNum).MaxOAMassFlowRate = 2.5;

// Case 1 - OA humrat = zone humrat - no high humidity operation
Node(ZoneEquipConfig(1).ZoneNode).HumRat = 0.006;
OAController(ControllerNum).OAHumRat = 0.006;
OAController(ControllerNum).CalcOAEconomizer(airLoopNum, outAirMinFrac, OASignal, HighHumidityOperationFlag, firstHVACIteration);
EXPECT_FALSE(OAController(ControllerNum).HighHumCtrlActive);
EXPECT_NEAR(OASignal, 0.0, 0.00001);

// Case 2 - OA humrat < zone humrat - high humidity operation
Node(ZoneEquipConfig(1).ZoneNode).HumRat = 0.006;
OAController(ControllerNum).OAHumRat = 0.006 - DataHVACGlobals::SmallHumRatDiff;
OAController(ControllerNum).CalcOAEconomizer(airLoopNum, outAirMinFrac, OASignal, HighHumidityOperationFlag, firstHVACIteration);
EXPECT_TRUE(OAController(ControllerNum).HighHumCtrlActive);
EXPECT_NEAR(OASignal, 0.8, 0.00001);

// Case 3 - OA humrat within tolerance of zone humrat - no high humidity operation
Node(ZoneEquipConfig(1).ZoneNode).HumRat = 0.006;
OAController(ControllerNum).OAHumRat = 0.006 - DataHVACGlobals::SmallHumRatDiff / 2.0;
OAController(ControllerNum).CalcOAEconomizer(airLoopNum, outAirMinFrac, OASignal, HighHumidityOperationFlag, firstHVACIteration);
EXPECT_FALSE(OAController(ControllerNum).HighHumCtrlActive);
EXPECT_NEAR(OASignal, 0.0, 0.00001);

// Case 4 - OA humrat slightly above zone humrat - no high humidity operation
Node(ZoneEquipConfig(1).ZoneNode).HumRat = 0.006;
OAController(ControllerNum).OAHumRat = 0.006 + DataHVACGlobals::SmallHumRatDiff / 2.0;
OAController(ControllerNum).CalcOAEconomizer(airLoopNum, outAirMinFrac, OASignal, HighHumidityOperationFlag, firstHVACIteration);
EXPECT_FALSE(OAController(ControllerNum).HighHumCtrlActive);
EXPECT_NEAR(OASignal, 0.0, 0.00001);
}

TEST_F(EnergyPlusFixture, OAControllerMixedAirSPTest)
{

Expand Down

6 comments on commit e05852f

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HighHumEcono7644 (mjwitte) - Win64-Windows-10-VisualStudio-16: OK (2589 of 2592 tests passed, 3 test warnings)

Messages:\n

  • 5 tests had: EIO diffs.
  • 3 tests had: ESO small diffs.
  • 5 tests had: MTR small diffs.
  • 4 tests had: Table small diffs.
  • 3 tests had: ESO big diffs.
  • 1 test had: MTR big diffs.
  • 1 test had: ERR diffs.
  • 1 test had: Table big diffs.

Failures:\n

regression Test Summary

  • Passed: 667
  • Failed: 3

Build Badge Test Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HighHumEcono7644 (mjwitte) - x86_64-Linux-Ubuntu-18.04-gcc-7.4: OK (2629 of 2632 tests passed, 3 test warnings)

Messages:\n

  • 3 tests had: ESO small diffs.
  • 5 tests had: MTR small diffs.
  • 4 tests had: EIO diffs.
  • 2 tests had: Table small diffs.
  • 3 tests had: ESO big diffs.
  • 1 test had: MTR big diffs.
  • 2 tests had: Table big diffs.
  • 1 test had: ERR diffs.

Failures:\n

regression Test Summary

  • Passed: 687
  • Failed: 3

Build Badge Test Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HighHumEcono7644 (mjwitte) - x86_64-Linux-Ubuntu-18.04-cppcheck: OK (0 of 0 tests passed, 0 test warnings)

Build Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HighHumEcono7644 (mjwitte) - x86_64-Linux-Ubuntu-18.04-custom_check: OK (11 of 11 tests passed, 0 test warnings)

Build Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HighHumEcono7644 (mjwitte) - x86_64-Linux-Ubuntu-18.04-gcc-7.4-UnitTestsCoverage-Debug: OK (1250 of 1250 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

HighHumEcono7644 (mjwitte) - x86_64-Linux-Ubuntu-18.04-gcc-7.4-IntegrationCoverage-Debug: OK (675 of 675 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

Please sign in to comment.