Notifications
You must be signed in to change notification settings - Fork 63
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
add placeholder for radiant controls tests
- Loading branch information
1 parent
c227aef
commit d66ec66
Showing
3 changed files
with
222 additions
and
205 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,205 @@ | ||
# A set of methods for testing hvac system methods | ||
|
||
# write errors to a log file | ||
def log_hvac_test_errors(errs) | ||
File.open("#{File.dirname(__FILE__)}/output/test_add_hvac_systems.log", 'a') do |file| | ||
errs.each { |err| file.puts(err) } | ||
end | ||
end | ||
|
||
# default hash for hvac tests | ||
def default_hvac_test_hash | ||
# example hash for an HVAC system type test | ||
# default optional arguments should match those in model_add_hvac_system | ||
default_hash = {template: '90.1-2013', | ||
model_test_name: nil, | ||
model_name: 'basic_2_story_office_no_hvac_60WWR', | ||
climate_zone: 'ASHRAE 169-2013-7A', | ||
system_type: nil, | ||
main_heat_fuel: nil, | ||
zone_heat_fuel: nil, | ||
cool_fuel: nil, | ||
zone_selection: 'all', | ||
hot_water_loop_type: nil, | ||
chilled_water_loop_cooling_type: nil, | ||
heat_pump_loop_cooling_type: nil, | ||
air_loop_heating_type: nil, | ||
air_loop_cooling_type: nil, | ||
zone_equipment_ventilation: nil, | ||
unmet_hrs_htg: 300.0, | ||
unmet_hrs_clg: 300.0,} | ||
return default_hash | ||
end | ||
|
||
# Runs an hvac test given an input model name and HVAC argument values | ||
# Uses the default hash above | ||
# | ||
# @param hvac_arguments [Hash] a hash | ||
def model_hvac_test(hvac_arguments) | ||
# Make the output directory if it doesn't exist | ||
output_dir = File.expand_path('output', File.dirname(__FILE__)) | ||
FileUtils.mkdir output_dir unless Dir.exist? output_dir | ||
|
||
reset_log | ||
errs = [] | ||
|
||
hash = default_hvac_test_hash.merge(hvac_arguments) | ||
template = hash[:template] | ||
model_test_name = hash[:model_test_name] | ||
model_name = hash[:model_name] | ||
climate_zone = hash[:climate_zone] | ||
system_type = hash[:system_type] | ||
main_heat_fuel = hash[:main_heat_fuel] | ||
zone_heat_fuel = hash[:zone_heat_fuel] | ||
cool_fuel = hash[:cool_fuel] | ||
zone_selection = hash[:zone_selection] | ||
hot_water_loop_type = hash[:hot_water_loop_type] | ||
chilled_water_loop_cooling_type = hash[:chilled_water_loop_cooling_type] | ||
heat_pump_loop_cooling_type = hash[:heat_pump_loop_cooling_type] | ||
air_loop_heating_type = hash[:air_loop_heating_type] | ||
air_loop_cooling_type = hash[:air_loop_cooling_type] | ||
zone_equipment_ventilation = hash[:zone_equipment_ventilation] | ||
unmet_hrs_htg = hash[:unmet_hrs_htg] | ||
unmet_hrs_clg = hash[:unmet_hrs_clg] | ||
|
||
standard = Standard.build(template) | ||
if model_test_name.nil? | ||
model_test_name = system_type.gsub(' ', '_') | ||
end | ||
model_dir = "#{output_dir}/hvac_#{model_test_name}" | ||
|
||
# Load the model if already created | ||
annual_run_success = false | ||
if File.exist?("#{model_dir}/AR/run/eplusout.sql") | ||
puts "test: '#{model_test_name}' results already available. Not re-rerunning energy simulation." | ||
model = OpenStudio::Model::Model.new | ||
sql = standard.safe_load_sql("#{model_dir}/AR/run/eplusout.sql") | ||
model.setSqlFile(sql) | ||
annual_run_success = true | ||
end | ||
|
||
# If not created, make and run annual simulation | ||
unless annual_run_success | ||
puts "test: '#{model_test_name}' results not available. Running energy simulation." | ||
# Load the test model | ||
model = standard.safe_load_model("#{File.dirname(__FILE__)}/models/#{model_name}.osm") | ||
|
||
# Assign a weather file | ||
standard.model_add_design_days_and_weather_file(model, climate_zone, '') | ||
standard.model_add_ground_temperatures(model, 'MediumOffice', climate_zone) | ||
|
||
zones = model.getThermalZones | ||
heated_and_cooled_zones = zones.select { |zone| standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } | ||
heated_zones = zones.select { |zone| standard.thermal_zone_heated?(zone) } | ||
cooled_zones = zones.select { |zone| standard.thermal_zone_cooled?(zone) } | ||
cooled_only_zones = zones.select { |zone| !standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } | ||
heated_only_zones = zones.select { |zone| standard.thermal_zone_heated?(zone) && !standard.thermal_zone_cooled?(zone) } | ||
system_zones = heated_and_cooled_zones + cooled_only_zones | ||
case zone_selection | ||
when 'heated_zones' | ||
zones = heated_zones | ||
when 'cooled_zones' | ||
zones = cooled_zones | ||
when 'heated_only_zones' | ||
zones = heated_only_zones | ||
when 'cooled_only_zones' | ||
zones = cooled_only_zones | ||
else # 'all' | ||
zones = system_zones | ||
end | ||
|
||
# Add the HVAC | ||
added_hvac = standard.model_add_hvac_system(model, system_type, main_heat_fuel, zone_heat_fuel, cool_fuel, zones, | ||
hot_water_loop_type: hot_water_loop_type, | ||
chilled_water_loop_cooling_type: chilled_water_loop_cooling_type, | ||
heat_pump_loop_cooling_type: heat_pump_loop_cooling_type, | ||
air_loop_heating_type: air_loop_heating_type, | ||
air_loop_cooling_type: air_loop_cooling_type, | ||
zone_equipment_ventilation: zone_equipment_ventilation) | ||
|
||
unless added_hvac | ||
errs << "Unable to apply hvac constructor for system type '#{system_type}' to model #{model_test_name}." | ||
log_hvac_test_errors(errs) | ||
log_messages_to_file("#{model_dir}/openstudio-standards.log", debug=false) | ||
return errs | ||
end | ||
|
||
# Save the model | ||
model.save("#{model_dir}/final.osm", true) | ||
|
||
# Perform a sizing run | ||
sizing_run_success = standard.model_run_sizing_run(model, "#{model_dir}/SR") | ||
unless sizing_run_success | ||
errs << "#{model_test_name} sizing run failed" | ||
log_hvac_test_errors(errs) | ||
log_messages_to_file("#{model_dir}/openstudio-standards.log", debug=false) | ||
return errs | ||
end | ||
|
||
# Check the conditioned floor area | ||
if standard.model_net_conditioned_floor_area(model).zero? | ||
errs << "Test model #{model_test_name} has no conditioned area." | ||
log_hvac_test_errors(errs) | ||
return errs | ||
end | ||
|
||
# If there are any multizone systems, reset damper positions | ||
# to achieve a 60% ventilation effectiveness minimum for the system | ||
# following the ventilation rate procedure from 62.1 | ||
standard.model_apply_multizone_vav_outdoor_air_sizing(model) | ||
|
||
# Apply the prototype HVAC assumptions | ||
standard.model_apply_prototype_hvac_assumptions(model, '', climate_zone) | ||
|
||
# Apply the HVAC efficiency standard | ||
apply_efficiency_success = standard.model_apply_hvac_efficiency_standard(model, climate_zone) | ||
unless apply_efficiency_success | ||
errs << "Failed to apply standard efficiencies after sizing run for model #{model_test_name}" | ||
errs << "#{apply_efficiency_success}" | ||
log_hvac_test_errors(errs) | ||
log_messages_to_file("#{model_dir}/openstudio-standards.log", debug=false) | ||
return errs | ||
end | ||
|
||
# Run the annual run | ||
annual_run_success = standard.model_run_simulation_and_log_errors(model, "#{model_dir}/AR") | ||
unless annual_run_success | ||
errs << "For #{model_test_name} annual run failed" unless annual_run_success | ||
log_hvac_test_errors(errs) | ||
log_messages_to_file("#{model_dir}/openstudio-standards.log", debug=false) | ||
return errs | ||
end | ||
end | ||
|
||
# Check unmet hours | ||
unmet_heating_hrs = standard.model_annual_occupied_unmet_heating_hours(model) | ||
unmet_cooling_hrs = standard.model_annual_occupied_unmet_cooling_hours(model) | ||
unmet_hrs = standard.model_annual_occupied_unmet_hours(model) | ||
if unmet_hrs | ||
if unmet_heating_hrs > unmet_hrs_htg | ||
errs << "Model #{model_test_name} has #{unmet_heating_hrs.round(1)} unmet occupied heating hours, more than the expected limit of #{unmet_hrs_htg}." | ||
end | ||
if unmet_cooling_hrs > unmet_hrs_clg | ||
errs << "Model #{model_test_name} has #{unmet_cooling_hrs.round(1)} unmet occupied cooling hours, more than the expected limit of #{unmet_hrs_clg}." | ||
end | ||
else | ||
errs << "Could not determine unmet hours for model #{model_test_name}. Simulation may have failed." | ||
end | ||
log_hvac_test_errors(errs) | ||
log_messages_to_file("#{model_dir}/openstudio-standards.log", debug=false) | ||
|
||
# @todo add checks for hvac enduse euis, ventilation unmet hours | ||
return errs | ||
end | ||
|
||
# Runs individual model hvac tests for an array of hvac test hashes | ||
# | ||
# @param test_set [Array] an array of test hashes | ||
def group_hvac_test(test_set) | ||
group_errs = [] | ||
test_set.each do |test_hash| | ||
errs = model_hvac_test(test_hash) | ||
group_errs << errs unless errs.empty? | ||
end | ||
assert(group_errs.size == 0, group_errs.join("\n")) | ||
end |