Skip to content

Database with efficiency parameters from public Heatpump Keymark datasets as well as parameter-sets and functions in order to simulate heat pumps (manufacturer+model or generic type)

License

Notifications You must be signed in to change notification settings

FZJ-IEK3-VSA/hplib

Repository files navigation

FZJ Logo

hplib - heat pump library

Repository with code to

  • build a database with relevant data from public Heatpump Keymark Datasets.
  • identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
  • simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.

For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.

[1] K. Schwamberger: „Modellbildung und Regelung von Gebäudeheizungsanlagen mit Wärmepumpen“, VDI Verlag, Düsseldorf, Fortschrittsberichte VDI Reihe 6 Nr. 263, 1991.

For reference purposes:

Documentation

If you're interested in how the database and parameters were calclulated, have a look into the Documentation HTML or Jupyter-Notebook. There you also find a simulation examples and a validation.


Heat pump models and Group IDs

The hplib_database.csv contains the following number of heat pump models, sorted by Group ID

[Group ID]: Count Regulated On-Off
Outdoor Air / Water [1]: 5812 [4]: 40
Brine / Water [2]: 283 [5]: 194
Water / Water [3]: 6 [6]: 6

Database

All resulting database CSV file are under License: CC BY 4.0.

The following columns are available for every heat pump of this library

Column Description Comment
Manufacturer Name of the manufacturer 30 manufacturers
Model Name of the heat pump model 506 models
Titel Name of the heat pump submodel use titel name for simulating
Date heat pump certification date 2016-07-27 to 2021-03-10
Type Type of heat pump model Outdoor Air/Water, Brine/Water, Water/Water
Subtype Subtype of heat pump model On-Off, Regulated
Group ID ID for combination of type and subtype 1 - 6
Rated Power low T [kW] Rated Power for low temperature level -7/34 °C
Rated Power medium T [kW] Rated Power for medium temperature level -7/52 °C
Refrigerant Refrigerant Type R134a, R290, R32, R407c, R410a, other
Mass of Refrigerant [kg] Mass of Refrigerant 0.15 to 17.5 kg
SPL indoor [dBA] Sound emissions indoor 15 - 68 dBA
SPL outdoor [dBA] Sound emissions outdoor 33 - 78 dBA
Bivalence temperature [°C] Minimum temperature heat pump is running without supplementary heater *T_biv not used in simulation
Tolerance temperature [°C] Minimum temperature heat pump is running with supplementary heater *TOL not used in simulation
Max. water heating temperature [°C] Maximum heating temperature *T_max not used in simulation
Poff [W] Eletrical power consumption, ? *P_off not used in simulation (0-110 W)
PTOS [W] Eletrical power consumption, ? *P_tos not used in simulation (0-404 W)
PSB [W] Eletrical power consumption, standby mode *P_sb not used in simulation (0-110 W)
PCKS [W] Eletrical power consumption, ? *P_cks not used in simulation (0-99 W)
eta low T [%] Efficiency for low temperature level 105-300%
eta medium T [%] Efficiency for medium temperature level 107-202%
SCOP seasonal COP 2,7-7,7
SEER low T seasonal EER for low Temperature Level 3,39-12,93
SEER medium T seasonal EER for medium Temperature Level 5,04-13,87
P_th_h_ref [W] Thermal heating power at -7°C / 52°C 2400 to 69880 W
P_th_c_ref [W] Thermal cooling power at ? 3000 to 53200 W
P_el_h_ref [W] Electrical power at -7°C / 52°C 881 to 29355 W
P_el_c_ref [W] Electrical power at ? 881 to 17647 W
COP_ref COP at -7°C / 52°C 1,53 to 7,95
EER_ref Electrical power at ? 1,99 to 10,8
p1-p4_P_th Fit-Parameters for thermal power -
p1-p4_P_el Fit-Parameters for electricl power P_el = P_el_ref * (p1T_in + p2T_out + p3 + p4*T_amb)
p1-p4_COP Fit-Parameters for COP COP = p1T_in + p2T_out + p3 + p4*T_amb
MAPE_P_th mean absolute percentage error for coefficient of performance (simulation vs. measurement) average = 19,7 %
MAPE_P_el mean absolute percentage error for electrical input power (simulation vs. measurement) average = 16,3 %
MAPE_COP mean absolute percentage error for thermal input power (simulation vs. measurement) average = 9,8 %
MAPE_P_dc mean absolute percentage error for coefficient of performance (simulation vs. measurement) average = 19,7 %
MAPE_P_el mean absolute percentage error for electrical input power (simulation vs. measurement) average = 16,3 %
MAPE_EER mean absolute percentage error for electrical input power (simulation vs. measurement) average = 16,3 %

Usage

  • Get repository with pip:
    • pip install hplib

or:

  • Download or clone repository:
    • git clone https://github.com/RE-Lab-Projects/hplib.git
    • Create the environment:
      • conda env create --name hplib --file requirements.txt

Create some code with from hplib import hplib and use the included functions hplib.load_database(), hplib.get_parameters, hplib.HeatPump(), hplib.HeatPump.simulate(), hplib.HeatingSystem.calc_brine_temp() and hplib.HeatingSystem.calc_heating_dist_temp()

Hint: The csv files in the output folder are for documentation and validation purpose. The code and database files, which are meant to be used for simulations, are located in the hplib folder.


Input-Data

The European Heat Pump Association (EHPA) hosts a website with the results of laboratory measurements from the keymark certification process. For every heat pump model a pdf file can be downloaded from https://keymark.eu/en/products/heatpumps/certified-products.

This repository is based on all pdf files that were download for every manufacturer on 2023-04-17.

Further development & possibilities to collaborate

If you find errors or are interested in developing together on the heat pump library, please create an ISSUE and/or FORK this repository and create a PULL REQUEST.

License

MIT License

Copyright (c) 2023

You should have received a copy of the MIT License along with this program. If not, see https://opensource.org/licenses/MIT

About Us

Institut TSA

We are the Institute of Energy and Climate Research - Techno-economic Systems Analysis (IEK-3) belonging to the Forschungszentrum Jülich. Our interdisciplinary department's research is focusing on energy-related process and systems analyses. Data searches and system simulations are used to determine energy and mass balances, as well as to evaluate performance, emissions and costs of energy systems. The results are used for performing comparative assessment studies between the various systems. Our current priorities include the development of energy strategies, in accordance with the German Federal Government’s greenhouse gas reduction targets, by designing new infrastructures for sustainable and secure energy supply chains and by conducting cost analysis studies for integrating new technologies into future energy market frameworks.

About

Database with efficiency parameters from public Heatpump Keymark datasets as well as parameter-sets and functions in order to simulate heat pumps (manufacturer+model or generic type)

Topics

Resources

License

Stars

Watchers

Forks

Packages

No packages published