🎁 Component now included in the core distribution 🎁
This component facilitates use of the Bosch BME680 sensor with ESPHome via the closed source Bosch BSEC library providing additional calculated indoor air quality measurements not available with the core component:
As of ESPHome 1.18 this component is included in the core distribution, however you may still wish to use this repository if a new release or experimental feature is available.
In ESPHome 1.18 and later you can use the external components system:
external_components:
- source: github://trvrnrth/esphome-bsec-bme680
Copy the components/bme680_bsec
directory into your ESPHome custom_components
directory (creating it if it does not exist). If you are running via Home Assistant this will be /config/esphome/custom_components/bme680_bsec
.
The I2C Bus must be set up in order for this component to work.
The following configuration shows the minimal set up to read temperature and humidity from the sensor.
i2c:
bme680_bsec:
sensor:
- platform: bme680_bsec
temperature:
name: "BME680 Temperature"
humidity:
name: "BME680 Humidity"
The following configuration shows all the available sensors and optional settings for the component. It also includes an example of filtering to guard against outliers, limit the number of updates sent to home assistant and reduce storage requirements in other systems such as influxdb used to store historical data.
For each sensor all other options from Sensor and TextSensor are also available for filtering, automation and so on.
bme680_bsec:
# i2c address
# -----------
# Common values are:
# - 0x76
# - 0x77
# Default: 0x76
address: 0x76
# Temperature offset
# ------------------
# Useful if device is in enclosure and reads too high
# Default: 0
temperature_offset: 0
# IAQ calculation mode
# --------------------
# Available options:
# - static (for fixed position devices)
# - mobile (for on person or other moveable devices)
# Default: static
iaq_mode: static
# Sample rate
# -----------
# This controls the sampling rate for gas-dependant sensors and will govern the interval
# at which the sensor heater is operated.
# By default this rate will also be used for temperature, pressure and humidity sensors
# but these can be overridden on a per-sensor level if required.
#
# Available options:
# - lp (low power - samples every 3 seconds)
# - ulp (ultra low power - samples every 5 minutes)
# Default: lp
sample_rate: ulp
# Interval at which to save BSEC state
# ------------------------------------
# Default: 6h
state_save_interval: 6h
sensor:
- platform: bme680_bsec
temperature:
# Temperature in °C
name: "BME680 Temperature"
sample_rate: lp
filters:
- median
pressure:
# Pressure in hPa
name: "BME680 Pressure"
sample_rate: lp
filters:
- median
humidity:
# Relative humidity %
name: "BME680 Humidity"
sample_rate: lp
filters:
- median
gas_resistance:
# Gas resistance in Ω
name: "BME680 Gas Resistance"
filters:
- median
iaq:
# Indoor air quality value
name: "BME680 IAQ"
filters:
- median
iaq_accuracy:
# IAQ accuracy as a numeric value of 0, 1, 2, 3
name: "BME680 Numeric IAQ Accuracy"
co2_equivalent:
# CO2 equivalent estimate in ppm
name: "BME680 CO2 Equivalent"
filters:
- median
breath_voc_equivalent:
# Volatile organic compounds equivalent estimate in ppm
name: "BME680 Breath VOC Equivalent"
filters:
- median
text_sensor:
- platform: bme680_bsec
iaq_accuracy:
# IAQ accuracy as a text value of Stabilizing, Uncertain, Calibrating, Calibrated
name: "BME680 IAQ Accuracy"
Indoor Air Quality measurements are expressed in the IAQ index scale with 25IAQ corresponding to typical good air and 250IAQ indicating typical polluted air after calibration.
The BSEC algorithm automatically gathers data in order to calibrate the IAQ measurements. The IAQ Accuracy sensor will give one of the following values:
Stabilizing
: The device has just started, and the sensor is stabilizing (this typically lasts 5 minutes)Uncertain
: The background history of BSEC is uncertain. This typically means the gas sensor data was too stable for BSEC to clearly define its reference.Calibrating
: BSEC found new calibration data and is currently calibrating.Calibrated
: BSEC calibrated successfully.
Every state_save_interval
, or as soon thereafter as full calibration is reached, the current algorithm state is saved to flash
so that the process does not have to start from zero on device restart.