# mh-z19
Read CO2 concentration from mh-z19 sensor and handle it.
Read CO<sub>2</sub> concentration from mh-z19 sensor and handle it.

![MH-Z19](https://camo.qiitausercontent.com/a270df1162ed5c3bf9968b24064b91eed0dfcc11/68747470733a2f2f71696974612d696d6167652d73746f72652e73332e616d617a6f6e6177732e636f6d2f302f34363534342f31353739663964622d306634302d373665382d303566332d3939336132346334376431382e706e67)

Expand Down Expand Up @@ -71,9 +71,16 @@ Necessary settings including serial port enabling are taken place in this script

### Install only sensor module

When using python 2.x
```bash:
pip install pip install mh-z19
pip install mh-z19
```

When using python 3.x
```bash:
pip3 install mh-z19
```

The differences of the interface between each Raspberry Pi model are resolved inside this module. For example, serial device name is difference between Raspberry Pi 3 and older model, but mh-z19 module automatically detect the model and read from appropriate serial device.

To use mh-z19, once you need to set up enabling serial port device on the Raspberry Pi.
Expand Down Expand Up @@ -183,7 +190,7 @@ The Pondslider also support ATT M2X. For detail, please refer [this](https://git
Features about calibration (both MH-Z19 & MH-Z19B), detection range change (MH-Z19B) and ABC logic on/off(MH-Z19B) are implemented at version 0.2.1 or later.

I'm afraid I've just only implemented these without test due to lack necessary devices and apparatus for the test, fx: standard concentration CO2 GAS, also MH-Z19B module.
If you have these devices or apparatus and try to use these functions generously, I'm really appreciate your [issue report](https://github.com/UedaTakeyuki/mh-z19/issues) regardless result were positive or negative.
If you have these devices or apparatus and try to use these functions generously, I really appreciate your [issue report](https://github.com/UedaTakeyuki/mh-z19/issues) regardless result were positive or negative.

For detail please refer this [wiki](https://github.com/UedaTakeyuki/mh-z19/wiki/CALIBRATION-&-detection-range).

Expand Down Expand Up @@ -213,7 +220,7 @@ So, returned temperature value might be not match with real temperature.
Please refer detail about my argument as [Is the undocumented TT value on the responses of command 0x86 really related to the ambient temperature?](https://github.com/UedaTakeyuki/mh-z19/wiki/Is-the-undocumented-TT-value-on-the-responses-of-command-0x86-really-related-to-the-ambient-temperature%3F).

### Use specific serial device.
In case you should use specific serial device insted of Raspberry Pi default serial device which this library automatically select, for example in case to need to use /dev/ttyUSB0 for **FT232 usb-serial converter** as [issue#12](https://github.com/UedaTakeyuki/mh-z19/issues/12), you can specify serial device by **--serial_device** option as follows:
In case you should use specific serial device instead of Raspberry Pi default serial device which this library automatically select, for example in case to need to use /dev/ttyUSB0 for **FT232 usb-serial converter** as [issue#12](https://github.com/UedaTakeyuki/mh-z19/issues/12), you can specify serial device by **--serial_device** option as follows:

```
sudo python -m mh_z19 --serial_device /dev/ttyUSB0
Expand Down