Where do you and/or the group mount your module or place your MAX18B20
probe inside the T962? Lay it on the bottom? Place it somewhere in
particular? Place it near the top? Lay it on the grate used to elevate
the board above the bottom? Is there a better place to locate the probe
or module?
Thank you
…On 2/15/2022 3:47 PM, Alpha Particle wrote:
The Maxim 1-wire device is also available as a module, and cheaper
than the device on its own...
https://www.dfrobot.com/product-164.html
... and it comes with wires and mounting holes for mounting away from
the PCB is necessary.
—
Reply to this email directly, view it on GitHub
<#224>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABZ4BKH5EZUUU57WMM7LRDTU3LQY7ANCNFSM5OQATNOA>.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
You are receiving this because you are subscribed to this
thread.Message ID:
***@***.***>
|
Always interesting when modules are cheaper than the components. In this case the module will likely interfere as the cold-junction sensing sensor ideally should be glued to the connector body, but feel free to add a link to the module in the wiki!
… On 16 Feb 2022, at 00:47, Alpha Particle ***@***.***> wrote:
The Maxim 1-wire device is also available as a module, and cheaper than the device on its own...
https://www.dfrobot.com/product-164.html
... and it comes with wires and mounting holes for mounting away from the PCB is necessary.
—
Reply to this email directly, view it on GitHub, or unsubscribe.
Triage notifications on the go with GitHub Mobile for iOS or Android.
You are receiving this because you are subscribed to this thread.
|
I bought the module today at about 60% of the cost of the device alone. It should arrive within a week. Btw, the + on the end of the IC part number differentiates the lead-free (Pb-free) version. |
The 18B20 needs to be in thermal contact with the thermocouple terminals on the controller PCB (for cold-junction compensation), it is not meant to measure the actual oven temperature.
… On 16 Feb 2022, at 08:03, southern-boy ***@***.***> wrote:
Where do you and/or the group mount your module or place your MAX18B20
probe inside the T962? Lay it on the bottom? Place it somewhere in
particular? Place it near the top? Lay it on the grate used to elevate
the board above the bottom? Is there a better place to locate the probe
or module?
Thank you
On 2/15/2022 3:47 PM, Alpha Particle wrote:
>
> The Maxim 1-wire device is also available as a module, and cheaper
> than the device on its own...
>
> https://www.dfrobot.com/product-164.html
>
> ... and it comes with wires and mounting holes for mounting away from
> the PCB is necessary.
>
> —
> Reply to this email directly, view it on GitHub
> <#224>,
> or unsubscribe
> <https://github.com/notifications/unsubscribe-auth/ABZ4BKH5EZUUU57WMM7LRDTU3LQY7ANCNFSM5OQATNOA>.
> Triage notifications on the go with GitHub Mobile for iOS
> <https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
> or Android
> <https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
>
> You are receiving this because you are subscribed to this
> thread.Message ID:
> ***@***.***>
>
—
Reply to this email directly, view it on GitHub <#224 (comment)>, or unsubscribe <https://github.com/notifications/unsubscribe-auth/AAYSRD6JR4MTE2DVPDY7CBLU3ND3RANCNFSM5OQATNOA>.
Triage notifications on the go with GitHub Mobile for iOS <https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675> or Android <https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
You are receiving this because you commented.
|
Mmm, I assumed it was measuring ambient (room) temperature... do I have that wrong? |
Ok, I found this very good article titled "Cold Junction Compensation in Thermocouple | Maxim Integrate". The website link is https://www.maximintegrated.com/en/design/technical-documents/app-notes/4/4026.html. IIRC, Maxim bought Dallas Semi about 15 years ago, so the article connects Maxim to Dallas who make the silicon device. |
A nice summary sentence or two from Example #1 in the above article is the following: "A temperature-sensing IC, located in close proximity to the thermocouple connector, measures the temperature in the vicinity of the cold junction. This method is based on the assumption that the temperature at the IC is approximately the same as the temperature at the cold junction." The "cold junction" referred to here is the junction where the thermocouple wires meet the connector contacts. Thanks for the advice above guys. Feel free to add this stuff to the wiki. |
The Maxim 1-wire device is also available as a module, and cheaper than the device on its own...
https://www.dfrobot.com/product-164.html
... and it comes with wires and mounting holes for mounting away from the PCB is necessary.
The text was updated successfully, but these errors were encountered: