SELF CLEAN, TURBO,ECO, 3D AUTO & Outdoor silent raw values, #2
Comments
Also the existing mhi-ac-ctrl doesn't respond when the ac has been shutdown and in self clean state/finished self clean state. |
Thanks for providing your logs. I have also the impression that the commands are not visible on the SPI. That matches my previous experiences. If you have a look on the user manual of commercial remote controls (e.g. RC-E5) you will see that only a small subset of commands which can be triggered by the IR-RC are supported by the SPI based RC. |
pls check if my findings are correct: |
According to SPI.md the DB0 values have the following meaning: |
Even if the remote Is in aother room, ac turns off. Also the power led
keeps blinking in self clean, which means it's a macro in the ac and not on
the remote..
Similarly turbo mode turns on the turbo led on ac.
3d auto turns on 3d auto led on ac
…On Tue, 21 Dec, 2021, 11:51 pm absalom-muc, ***@***.***> wrote:
According to SPI.md
<https://github.com/absalom-muc/MHI-AC-Trace/blob/main/SPI.md> the DB0
values have the following meaning:
on:49 = Vanes swing, COOL, Power on
off:49 = Vanes swing, COOL, Power off
self clean:4d = Vanes swing, FAN, Power on
I can't see something specific to self clean. According to the issue "SELF
CLEAN operation" to prevent mold #67
<absalom-muc/MHI-AC-Ctrl#67 (comment)>
the fan works for about 2h. You could check if the fan off command after 2h
is triggered by the IR-RC to find out if self clean is a function of the AC
or a (macro) function of the IR-RC.
This could be similar to the timer functions of the IR-RC. As far as I
know this is completely controlled by the IR-RC, not by the AC itself (when
you carry the IR-RC in another room without visual connection to the AC I
assume a programmed timer doesn't work.) - best guess, I never tested it.
—
Reply to this email directly, view it on GitHub
<#2 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AF6ODFPVSNUN6QNKCSL5DQ3USDARHANCNFSM5KMD7JTQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
You are receiving this because you authored the thread.Message ID:
***@***.***>
|
ah o.k. I have not so many LEDs. Then my assumption related to the timer might be also wrong. |
Hi, I did some traces on my SCM 45-ZS-W & SRK 35-ZS-W too. May just for reference.
|
self clean captured.
swing L/R U/D doesnt reflect changes immediately, even silent mode/ 3d auto. i've tried to capture by setting it in respective modes and turning on ac.