[MISC] make explicit that EDF+ (and for EEG: BDF+) are included in iEEG / EEG format requirements #831

Merged
merged 1 commit into from
Aug 4, 2021
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
6 changes: 4 additions & 2 deletions src/04-modality-specific-files/03-electroencephalography.md
Original file line number Diff line number Diff line change
Expand Up @@ -24,7 +24,8 @@ no single standard that all researchers agree on. For BIDS, EEG data MUST be
stored in one of the following formats:

- [European data format](https://www.edfplus.info/)
(Each recording consisting of a `.edf` file)
(including [`edf+`](https://www.edfplus.info/specs/edfplus.html);
each recording consisting of a `.edf` file)

- [BrainVision Core Data Format](https://www.brainproducts.com/productdetails.php?id=21&tab=5)
(Each recording consisting of a `.vhdr`, `.vmrk`, `.eeg` file triplet)
Expand All @@ -33,7 +34,8 @@ stored in one of the following formats:
(Each recording consisting of a `.set` file with an optional `.fdt` file)

- [Biosemi](https://www.biosemi.com/) data format
(Each recording consisting of a `.bdf` file)
(including [`bdf+`](https://www.teuniz.net/edfbrowser/bdfplus%20format%20description.html);
each recording consisting of a `.bdf` file)

It is RECOMMENDED to use the European data format, or the BrainVision data
format. It is furthermore discouraged to use the other accepted formats over
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -14,8 +14,9 @@ The iEEG community uses a variety of formats for storing raw data, and there is
no single standard that all researchers agree on. For BIDS, iEEG data MUST be
stored in one of the following formats:

- [European Data Format](https://www.edfplus.info/)
(Each recording consisting of a `.edf` file)
- [European data format](https://www.edfplus.info/)
(including [`edf+`](https://www.edfplus.info/specs/edfplus.html);
each recording consisting of a `.edf` file)

- [BrainVision Core Data Format](https://www.brainproducts.com/productdetails.php?id=21&tab=5)
(Each recording consisting of a `.vhdr`, `.vmrk`, `.eeg` file triplet)
Expand Down