Skip to content

chestwood96/SlideSwipe

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

23 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

SlideSwipe 1.0 (magnetic probe for the voron v0.1)

Introduction

I liked the idea of the SideSwipe probe but didn't like that it would require either printing with the door open or losing Y travel, so I made my own take on the idea.

Taking probe Stowing probe
Take Stow

Pros and cons compared to SideSwipe

Pro Con
+ Fully integrated - Requires new cowling (and the accompanying rebuild of everything on it)
+ Cables well hidden - More complex (more parts, more steps)
+ No loss in y area with the door closed
+ Bed can't hit the arm
+ Hot-swappable switches (ok, fair that's a bit of a gimmick)

There is also the option of mounting it to the front of the cowling instead of using a new cowling if that is not an option.

BOM

Parts

  • 1x MG90s Metal gear servo (the SG90 plastic gear ones work too but are not reccomended)
  • 1x Omron(or omron size) mouse switch (I am using a kailh GM4.0 switch, but it's only marginally better than all the other switches I tested)
  • 5x 6x3mm round magnets (I used the cheapest crappiest ones I could find off aliexpress, need to be at least 2.7mm thick)
  • 1x 300mm servo extender cable (or make your own)
  • 1x 1.5m of stranded wire with <1.2mm od (I tested 30awg silicone wire and 26awg ptfe wire)
  • 2x JST-XH housing (only one housing and 2 crimping terminals if you don't want to wire to the 5pin probe port on the SKR mini E3 v2)
  • 7x JST-XH female crimping terminal
  • 1x (optional but reccomended) JST-PH or JST-XH 2pin male and female connector pair
  • 3x 16mm piece of 4od2id PTFE tube (does not need to be the nice stuff)
  • 1x 7mm piece of 4od2id PTFE tube (does not need to be the nice stuff)

Screws

  • 7x M3x6 Socket head screw (cap head probably work too, as long as they are at least slightly attracted to magnets)
  • 2x M3x8 Cap head screw
  • 2x M3 nut

Tools

  • Some superglue
  • Tools to crimp JST-XH (and optionally JST-PH)
  • A multimeter

Printing

All parts are designed to print in the orientation they come in and do not require supports (If you have really bad overhang performance you can add a bit of support for the probe but it should not be necessary).

Designed to print in ABS at 0.4mm outer perimeter width and 0.2mm layer height.

I recommend ironing for the following parts, the rest can be printed without:

  • Arm1
  • Arm2
  • ProbeCarrierTop
  • ProbeCarrierBottom
  • RailMountTop

If you are going to do accents, I recommend printing the following parts in the accent color:

  • Arm1
  • Arm2
  • Probe

Build

Parts

Probe

ProbeParts

Crimp two short (about 5cm but cutting off is easier than adding...) pieces of wire and put them in the outer-most places in the JST-XH 5pin housings. I recommend testing the cripms at this point. ProbeCrimp

Thread the wires through the holes, then put the connector in the probe. Make sure it's the right way around. Don't put it in all the way yet. ProbeInsert

Add some superglue to the back of the connector and carefully push it all the way in while making sure the wires are not pinched. Make sure superglue does not get anywhere it shouldn't. ProbeWires1

Shorten the wires, so they extend a little past the edge (5-10mm is fine). ProbeWires2

Strip as much of the wire as you can. You probably can't use normal wire strippers for that. ProbeWires3

Put the stripped wires in the magnet holes. Make sure the unstripped parts are in the grooves, so they don't get in the way. ProbeWires4

Add some superglue to the rim of the holes and put the magnets in the holes with the same polarity facing up. Make sure the glue does not get on the wires too much and there is none on the top of the magnets. Also, try to get them as parallel with each other as possible (pressing them against a flat surface while drying helps).

Test continuity between the magnet and the jst pins. ProbeMagnets

After the glue has dried insert the microswitch so the plunger is in the middle of the probe.

With the switch inserted there should be continuity between the magnets unless the switch is pressed. ProbeSwitch

Screw on an M3x6 screw into the hole of the side of the probe. (Make sure the screw is at least somewhat attracted to a magnet) ProbeScrew ProbeScrew2

The screw is not only attracted to magnets in one direction (because of the influence from the magnet above it). Install the retention magnet in the probe carrier in the right orientation (using the probe as a tool for installing it can help). Then add some glue to the back of the magnet to hold it in place (there is a hole in the part to allow easier gluing and removal of the magnet) ProbeCarrier ProbeCarrier2

The probe should now stick in the carrier and not just fall out. ProbeCarrier3

Cowling

CowlingParts

In this guide I am putting a connector (jst-ph) on the cowling for easier removal, you can use any other small enough connector or wire it directly (you just need to make the wires long enough to go through the umbilical and to your mainboard plus a little slack, so you can take the cowling of at least somewhat)

Crimp your connector to two short pieces of wire to your connector and feed them through the wire holes in the back of the cowling. Check your crimps. CowlingWires

Cut them so about 3-4cm of wire are extending past the holes, then strip about 2cm off those. CowlingWires2

Pull the wires back until there is only stripped wire in the holes and curl the rest of the wire in the holes. CowlingWires3

Put some superglue on the rims of the holes and push the magnets in the holes in the right orientation to match the probe. Try to get those two as parallel to each other as possible by pushing them against a flat surface.

Make sure there is no glue on the top of the magnets and check continuity between the magnets and the wires.

CowlingMagnets

If the magnets were put in the right way the probe should stick to the cowling. Test the continuity between the wires. There should be continuity between the wires unless the switch is pressed or the probe is removed. CowlingAndProbe

Probe holder

Find the servo arm that fits the arm the best and cut off anything else on that arm if there is anything. ArmServoArm ArmServoArm2

Zero the servo (and check that it has at least over 90° of travel and isn't a continuously rotating one) and install the chosen arm so it points a little over 90° when at the max point (picture is the max point). ArmServoArm3

Pull the servo wire through the hole. ArmServoMount

Insert the servo into the mount and fix it using 2 M3x6 screws ArmServoMount2 ArmServoMount3 ArmServoMount4

Insert the short piece of PTFE in the left hole of "RailMountTop". ArmServoMount5

Insert one of the longer pieces of ptfe into one of the holes of "Arm2" (the solid one). Arm1

Put "Arm2" and "Arm1" onto the servo carrier like shown. Arm2

Screw "RailMountTop" onto the servo carrier using 2 M3x6 screws. Arm3

Put the other two longer pieces of ptfe into the remaining two holes in the arms. Arm4

Put "ProbeCarrierTop" and "ProbeCarrierBottom" on the arms and screw them down using 2 M3x6 screws. Arm5 Arm6

Add nuts in the pockets on the inside of the mount. ArmNuts

That should be the physical build done. Arm7

Installation

Installing the new cowling

The installation is the same as with the regular one, refer to the manual for that.

Installing the probe arm

put the servo wire into the groove of the extrusion and tip the mount into it. Fix the assembly using the screws on the side.

Adjust the height to where it can grab the probe, but the arm does not hit the printhead then fix it in place.

Route the servo wire through the slot in the front extrusion upwards into the slot of the top extrusion. The stock wire should be just long enough to pass through the panel, though you'll probably have to remove the connector housing for that.

Wiring

In this example I am hooking up to the "BL-Touch" connector of the SKR mini e3 v2.0

If you are fancy you can crimp that onto a 5 pin jst-xh plug, otherwise you can just plug it straight into the header.

Here is a crude diagram of how this could be wired up. If you wired it differently you'll need to pay special attention during the klipper setup. Wiring

Klipper setup

Put this in your klipper config. If you wired it differently, adjust the pins for the probe and the servo

[homing_override]
axes: z
gcode:
    SET_KINEMATIC_POSITION Z=0
    G1 Z5
    G28 X Y
    Query_Probe
    SS_CONDITIONAL_TAKE_PROBE
    G1 X40 Y110
    G28 Z
    G91
    G1 Z1
    G90

[probe]
pin: ^PC14
x_offset: 20
y_offset: 0
z_offset: 10
speed: 20.0
samples: 2
sample_retract_dist: 5.0
lift_speed: 30.0
samples_tolerance: 0.01
samples_tolerance_retries: 15
deactivate_on_each_sample: 0

[bed_mesh]
speed: 200
horizontal_move_z: 25
mesh_min: 25,25
mesh_max: 95, 95
probe_count: 3,3
algorithm: bicubic

[servo probeServo]
pin: PA1
minimum_pulse_width: 0.000544

[gcode_macro SS_PICKUP_POS]
variable_x: 115
variable_y: 50
variable_z: 30
gcode:
  M118 pickup pos X:{printer["gcode_macro SS_PICKUP_POS"].x} Y:{printer["gcode_macro SS_PICKUP_POS"].y} Z:{printer["gcode_macro SS_PICKUP_POS"].z}

[gcode_macro SS_DEPLOY]
gcode:
    SET_SERVO SERVO=probeServo ANGLE=160
    G4 P500 # wait for deploy
    #SET_SERVO SERVO=probeServo WIDTH=0 # OFF
    
[gcode_macro SS_RETRACT]
gcode:
    SET_SERVO SERVO=probeServo ANGLE=20
    G4 P500 # wait for retract
    SET_SERVO SERVO=probeServo WIDTH=0 # OFF

[gcode_macro SS_TAKE_PROBE]
gcode:
    G1 Z{printer["gcode_macro SS_PICKUP_POS"].z} F5000
    G1 X{printer["gcode_macro SS_PICKUP_POS"].x - 20} Y{printer["gcode_macro SS_PICKUP_POS"].y} F5000
    SS_DEPLOY
    G1 X{printer["gcode_macro SS_PICKUP_POS"].x}
    G1 Y{printer["gcode_macro SS_PICKUP_POS"].y + 50}
    G1 X{printer["gcode_macro SS_PICKUP_POS"].x - 20}
    SS_RETRACT

[gcode_macro SS_STOW_PROBE]
gcode:
    G1 Z{printer["gcode_macro SS_PICKUP_POS"].z} F5000
    G1 X{printer["gcode_macro SS_PICKUP_POS"].x - 20} Y{printer["gcode_macro SS_PICKUP_POS"].y + 50} F5000
    SS_DEPLOY
    G1 X{printer["gcode_macro SS_PICKUP_POS"].x}
    G1 Y{printer["gcode_macro SS_PICKUP_POS"].y} F2000
    G1 X{printer["gcode_macro SS_PICKUP_POS"].x - 20} F5000
    SS_RETRACT

[gcode_macro SS_CONDITIONAL_TAKE_PROBE]
gcode:
    {% set P = printer.probe.last_query %}
    {% if P %}
        SS_TAKE_PROBE
    {% endif %}

[gcode_macro SS_CONDITIONAL_STOW_PROBE]
gcode:
    {% set P = printer.probe.last_query %}
    {% if not P %}
        SS_STOW_PROBE
    {% endif %}

[gcode_macro G29]
gcode:
    G91
    G1 Z1
    G90
    Query_Probe
    SS_CONDITIONAL_TAKE_PROBE
    BED_MESH_CALIBRATE
    SS_STOW_PROBE

[force_move]
enable_force_move: True

[respond]

and replace your z endstop with the probe:

endstop_pin: probe:z_virtual_endstop

Also add the following to your print start (either in klipper or in your slicer) to make sure it won't try to print with the probe attached (the query_probe first is important):

    Query_Probe
    SS_CONDITIONAL_STOW_PROBE

After the calibration you should be able to use the G29 macro to mesh level your bed.

Calibrating the servo angles

Using the servo command, find good values where the servo reliably hits the deployed and stowed position. The mechanism mechanically limits the travel. Having the servo try to push against it the whole time isn't great for it, so try to find some values that don't go way over the limits.

Once you have found the right values, update the "SS_DEPLOY" and "SS_RETRACT" macros with your new values.

Calibrating the pickup position

This should already be somewhat acurate but if it isn't find the pickup position and update the "SS_PICKUP_POS" macro accordingly.

First tests

Check the probe and config

Let's see if klipper can see the probe. The "QUERY_PROBE" command is our friend here.

With the probe attached (by hand for now) it should return "open". With the button pressed it should return "triggered" and with the probe removed it should also return "triggered". If this is not true don't proceed, and go check your wiring and config.

If that worked out put the probe in the probe carrier and do a test run. The homing override uses the probe so all we'll have to do to see if it works is run G28.

It should now home x and y, then pick up the probe and probe for Z. Be ready to cut power if something weird happens.

To make sure everything has settled I like to do a couple hundred probes before I do stuff like calibrating the Z-offset.

PROBE_ACCURACY samples=100