-
Notifications
You must be signed in to change notification settings - Fork 106
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #86 from asht-cisco/main
Add Firepower 4100 and 9300 MIO MIBs.
- Loading branch information
Showing
78 changed files
with
271,059 additions
and
0 deletions.
There are no files selected for viewing
Large diffs are not rendered by default.
Oops, something went wrong.
Large diffs are not rendered by default.
Oops, something went wrong.
Large diffs are not rendered by default.
Oops, something went wrong.
Large diffs are not rendered by default.
Oops, something went wrong.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,275 @@ | ||
-- ********************************************************************* | ||
-- CISCO-FIREPOWER-BMC-MIB.my | ||
-- | ||
-- MIB representation of the Cisco Firepower | ||
-- BMC management information model package | ||
-- | ||
-- Created May 2024 by Charles Bullis | ||
-- | ||
-- Copyright (c) 2005-2024 Cisco Systems, Inc. All rights reserved. | ||
-- | ||
-- ********************************************************************* | ||
|
||
CISCO-FIREPOWER-BMC-MIB DEFINITIONS ::= BEGIN | ||
|
||
IMPORTS | ||
MODULE-IDENTITY, | ||
OBJECT-TYPE, | ||
Counter32, | ||
Gauge32, | ||
TimeTicks, | ||
Counter64, | ||
Unsigned32 | ||
FROM SNMPv2-SMI | ||
TEXTUAL-CONVENTION, | ||
RowPointer, | ||
DateAndTime, | ||
DisplayString, | ||
MacAddress, | ||
TimeInterval, | ||
TimeStamp, | ||
TruthValue | ||
FROM SNMPv2-TC | ||
SnmpAdminString | ||
FROM SNMP-FRAMEWORK-MIB | ||
InetAddressIPv4, | ||
InetAddressIPv6 | ||
FROM INET-ADDRESS-MIB | ||
ciscoMgmt | ||
FROM CISCO-SMI | ||
CiscoNetworkAddress, | ||
Unsigned64, | ||
CiscoInetAddressMask, | ||
CiscoAlarmSeverity, | ||
TimeIntervalSec | ||
FROM CISCO-TC | ||
ciscoFirepowerMIBObjects, | ||
CfprManagedObjectId, | ||
CfprManagedObjectDn | ||
FROM CISCO-FIREPOWER-MIB | ||
CfprBmcSELCntEqptClassId, | ||
CfprBmcSELCntEqptInstIdPropId, | ||
CfprBmcSELCntStatsClassId | ||
FROM CISCO-FIREPOWER-TC-MIB; | ||
|
||
cfprBmcObjects MODULE-IDENTITY | ||
LAST-UPDATED "202405160000Z" | ||
ORGANIZATION "Cisco Systems Inc." | ||
CONTACT-INFO | ||
"Cisco Systems | ||
Customer Service | ||
|
||
Postal: 170 W Tasman Drive | ||
San Jose, CA 95134 | ||
USA | ||
|
||
Tel: +1 800 553-NETS | ||
|
||
E-mail: firepower-mibs@cisco.com" | ||
DESCRIPTION | ||
"MIB representation of the Cisco Firepower | ||
BMC management information model package" | ||
::= { ciscoFirepowerMIBObjects 6 } | ||
|
||
cfprBmcSELCounterTable OBJECT-TYPE | ||
SYNTAX SEQUENCE OF CfprBmcSELCounterEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter managed object table" | ||
::= { cfprBmcObjects 1 } | ||
|
||
cfprBmcSELCounterEntry OBJECT-TYPE | ||
SYNTAX CfprBmcSELCounterEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"Entry for the cfprBmcSELCounterTable table." | ||
INDEX { cfprBmcSELCounterInstanceId } | ||
::= { cfprBmcSELCounterTable 1 } | ||
|
||
CfprBmcSELCounterEntry ::= SEQUENCE { | ||
cfprBmcSELCounterInstanceId CfprManagedObjectId, | ||
cfprBmcSELCounterDn CfprManagedObjectDn, | ||
cfprBmcSELCounterRn SnmpAdminString, | ||
cfprBmcSELCounterBitmask SnmpAdminString, | ||
cfprBmcSELCounterCollInterval Gauge32, | ||
cfprBmcSELCounterContClassId CfprBmcSELCntEqptClassId, | ||
cfprBmcSELCounterContInstId SnmpAdminString, | ||
cfprBmcSELCounterContInstIdPropId CfprBmcSELCntEqptInstIdPropId, | ||
cfprBmcSELCounterEqptClassId CfprBmcSELCntEqptClassId, | ||
cfprBmcSELCounterEqptInstId SnmpAdminString, | ||
cfprBmcSELCounterEqptInstIdPropId CfprBmcSELCntEqptInstIdPropId, | ||
cfprBmcSELCounterGlobalId SnmpAdminString, | ||
cfprBmcSELCounterLocalId SnmpAdminString, | ||
cfprBmcSELCounterPcGlobalId SnmpAdminString, | ||
cfprBmcSELCounterPcLocalId SnmpAdminString, | ||
cfprBmcSELCounterStatsClassId CfprBmcSELCntStatsClassId, | ||
cfprBmcSELCounterStatsPropId INTEGER, | ||
cfprBmcSELCounterThreshold Gauge32, | ||
cfprBmcSELCounterValue SnmpAdminString | ||
} | ||
|
||
cfprBmcSELCounterInstanceId OBJECT-TYPE | ||
SYNTAX CfprManagedObjectId | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"Instance identifier of the managed object." | ||
::= { cfprBmcSELCounterEntry 1 } | ||
|
||
cfprBmcSELCounterDn OBJECT-TYPE | ||
SYNTAX CfprManagedObjectDn | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:dn managed object property" | ||
::= { cfprBmcSELCounterEntry 2 } | ||
|
||
cfprBmcSELCounterRn OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:rn managed object property" | ||
::= { cfprBmcSELCounterEntry 3 } | ||
|
||
cfprBmcSELCounterBitmask OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:bitmask managed object property" | ||
::= { cfprBmcSELCounterEntry 4 } | ||
|
||
cfprBmcSELCounterCollInterval OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:collInterval managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 5 } | ||
|
||
cfprBmcSELCounterContClassId OBJECT-TYPE | ||
SYNTAX CfprBmcSELCntEqptClassId | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:contClassId managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 6 } | ||
|
||
cfprBmcSELCounterContInstId OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:contInstId managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 7 } | ||
|
||
cfprBmcSELCounterContInstIdPropId OBJECT-TYPE | ||
SYNTAX CfprBmcSELCntEqptInstIdPropId | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:contInstIdPropId | ||
managed object property" | ||
::= { cfprBmcSELCounterEntry 8 } | ||
|
||
cfprBmcSELCounterEqptClassId OBJECT-TYPE | ||
SYNTAX CfprBmcSELCntEqptClassId | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:eqptClassId managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 9 } | ||
|
||
cfprBmcSELCounterEqptInstId OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:eqptInstId managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 10 } | ||
|
||
cfprBmcSELCounterEqptInstIdPropId OBJECT-TYPE | ||
SYNTAX CfprBmcSELCntEqptInstIdPropId | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:eqptInstIdPropId | ||
managed object property" | ||
::= { cfprBmcSELCounterEntry 11 } | ||
|
||
cfprBmcSELCounterGlobalId OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:globalId managed object property" | ||
::= { cfprBmcSELCounterEntry 12 } | ||
|
||
cfprBmcSELCounterLocalId OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:localId managed object property" | ||
::= { cfprBmcSELCounterEntry 13 } | ||
|
||
cfprBmcSELCounterPcGlobalId OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:pcGlobalId managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 14 } | ||
|
||
cfprBmcSELCounterPcLocalId OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:pcLocalId managed object property" | ||
::= { cfprBmcSELCounterEntry 15 } | ||
|
||
cfprBmcSELCounterStatsClassId OBJECT-TYPE | ||
SYNTAX CfprBmcSELCntStatsClassId | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:statsClassId managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 16 } | ||
|
||
cfprBmcSELCounterStatsPropId OBJECT-TYPE | ||
SYNTAX INTEGER | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:statsPropId managed | ||
object property" | ||
::= { cfprBmcSELCounterEntry 17 } | ||
|
||
cfprBmcSELCounterThreshold OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:threshold managed object property" | ||
::= { cfprBmcSELCounterEntry 18 } | ||
|
||
cfprBmcSELCounterValue OBJECT-TYPE | ||
SYNTAX SnmpAdminString | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Cisco Firepower bmc:SELCounter:value managed object property" | ||
::= { cfprBmcSELCounterEntry 19 } | ||
|
||
END |
Oops, something went wrong.