Acquisition software for serial block-face imaging. Uses pycromanager and Qt.

License

Notifications You must be signed in to change notification settings

ckolluru/3D-MUSE-acquire

Repository files navigation

3D-MUSE-acquire

Read the microtome instruction manual first, available on the Leica website. https://www.leicabiosystems.com/sites/default/files/media_product-download/2022-11/HistoCore_NANOCUT_R_IFU_1v6I_en.pdf

Setting up the software

Install micromanager nightly build from 20230530
https://download.micro-manager.org/nightly/2.0/Windows/

Choose the 20230530 from the list MMSetup_64bit_2.0.1_20230530.exe

Install Spinnaker SDK 2.3.0.77 from FLIR (needs an account on their website)
Select Application Development (not Evaluation) during the install process screens
Also get the Visual Studio 2010 drivers in the second screen during the installation
https://www.flir.com/products/spinnaker-sdk/?vertical=machine+vision&segment=iis

Follow instructions on these pages
https://www.cairn-research.co.uk/wp-content/uploads/2019/05/READ-ME-INSTALLATION.pdf
https://micro-manager.org/Spinnaker

Install python 3.11 from Microsoft Store
https://www.microsoft.com/store/productid/9NRWMJP3717K?ocid=pdpshare

Download a zip of this repository
https://github.com/ckolluru/3D-MUSE-acquire/archive/refs/heads/master.zip

Unzip the contents of this zip file and move it to a suitable folder location.

For simply running the software, Visual Studio code is not required. But, see instructions below if you want a development environment setup.

Tested only on Windows 10 and Windows 11 for now

Development environment setup

If you want to set up a development environment and make changes to the code, then you need Visual Studio Code and Git.

Install Visual Studio Code
https://code.visualstudio.com/

Install Git
https://git-scm.com/download/win

Open Visual Studio Code

Click on the extensions button on the left, search for python, and install the extension. This is not a python interpreter, this just allows visual studio to format and display python code properly. The python interpreter is installed on the system using the steps mentioned above (from Microsoft Store).

Set the default terminal profile. Press Ctrl + Shift + P. Search for Terminal: Select Default Profile. Select the command line.

Now go to File > Open Folder. Select the folder with this code that was unzipped. You should see all the files in the explorer tab on the left. Open main.py file and pin it.

Now on the menu bar, select terminal > new terminal. In the terminal window, run the pip install command below. The requirements.txt file has a list of all python libraries that the software depends on.

pip install -r requirements.txt

If pip install runs into issues manually install following packages

pip install Pillow
pip install ITKMontage
pip install tqdm
pip install zarr
pip install scikit-image
pip install opencv-python

Install Zaber Launcher from here: https://www.zaber.com/software

Setting up without a development environment

If you are not setting up Git and Visual Studio Code, open command prompt. Navigate to the folder containing this code. Run the same pip install command.

pip install -r requirements.txt

Setting up micromanager

Run Micro-Manager, select tools-options, and check the box that says Run server on port 4827 (you only need to do this once).

In Micromanager, a configuration file is created to connect to the specific hardware. Open Micromanager and select (none) in the configuration window.

Go to devices > hardware configuration wizard and follow the steps from the micromanager Zaber device pages, to set up the XYZ stages. We set up one XYStage and one Stage. The XYstage correspond to X-VSR stage and X-LSM stage. Use Zaber Launcher to identify which port each of the XYZ stages are connected to and the controller device number (one of either 01, 02, 03).

We will use the port information to setup the stage in Micromanager. Use the Zaber wiki to identify the correct values to enter (https://www.zaber.com/w/Software/MicroManager#Setting_Up_A_Two-Axis_System).

Axis Number should be set to 1,
controller device numbers come from Zaber Launcher,
Linear Motion Per Rev is 1.2192 for Y stage (X-VSR) and 0.6096 for X-LSM stages
Port is the COM port from Zaber Launcher.
This setup may change if you are using the Z stage with the linear encoder.  

Additional properties for the stages:

AnswerTimeout: 500.0000  
BaudRate: 115200  
DTR: Disable  
DataBits: 8  
DelayBetweenCharsMs: 0.0000  
Fast USB to Serial: Disable  
Handshaking: Off  
Parity: None  
StopBits: 1  
Verbose: 1    

Select spinnaker camera and find the blackfly camera you are using, and set it up as well. The status should say OK. We also set up DemoCamera (DHub) and select the Demo Objective (this is a dummy item that lets us specify an objective magnification)

Objective mag setup 1


Select ok on this window

Objective mag setup 2


Select the Demo Objective

Objective mag setup 3


You should see a DHub and DObjective devices setup

Objective mag setup 4

Leave defaults on steps 3 and 4. In step 3, it may leave the focus stage direction empty, select positive towards the sample if that is the case. In step 5, it should show you a table of states and labels for the demo objective turret. Leave it as is.

Objective mag setup 5

Save the configuration file in a suitable location, preferably in the same folder as this repository. Next, we will enter the pixel size values for each of the objectives. Go to Devices > Pixel Size Calibration, and select New. Click OK on the warning window where it says devices will move

Pixel size cal 1

Give a suitable name in the pixel config editor (say 4x), enter pixel size (um), and click on the calculate button. The 3x3 affine transform will be updated based on the pixel size. Select the DObjective-Label for the use in group checkbox. The python code assumes that the 4x is objective-A, 10x is objective-B, 2x is objective-C. Select the current property value appropriately from the dropdown in DObjective-Label row

Pixel size cal 2


Repeat this process for all the objectives you need, use the appropriate objective names
Pixel size cal 3

Pixel size cal 4


When you close this window above, it will ask to save this pixel configuration to the same device cfg file, it is OK to overwrite. Now, when the objective magnification is used from this software's dropdown, Micromanager will automatically be updated. See the bottom most line in the micromanager window, where it says

Image info (from camera), Image intensity range, xyz nm/px
Ensure that xyz is the number you expect.

Ensure that micromanager is running a server to talk to pycromanager. Go to Tools > Options > Run server on port 4827.

Micromanager config groups and properties

ConfigGroup,Initialization,Startup,Gain, Auto, Off  
ConfigGroup,Initialization,Startup,Gain, 18  
ConfigGroup,Initialization,Startup,Stage,Acceleration [m/s^2],0.0250  
ConfigGroup,Initialization,Startup,Stage,Speed [mm/s],0.5000  
ConfigGroup,Initialization,Startup,XYStage,Acceleration X [m/s^2],0.0250  
ConfigGroup,Initialization,Startup,XYStage,Acceleration Y [m/s^2],0.0250  
ConfigGroup,Initialization,Startup,XYStage,Speed X [mm/s],1.0000  
ConfigGroup,Initialization,Startup,XYStage,Speed Y [mm/s],1.0000  
ConfigGroup,Initialization,Startup,XYStage,TransposeMirrorX,1  
ConfigGroup,Initialization,Startup,XYStage,TransposeMirrorY,1  
ConfigGroup,Initialization,Startup,Arduino-Switch,Label,Switch off all  
ConfigGroup,Initialization,Startup,Arduino-Shutter,OnOff,1  

Another config group should be created for the Objective with Objectives A-F as presets.

Modifications based on COM ports

Ensure that the COM port for the Arduino is correctly entered. It is hardcoded for now. In main.py, go to the initialize_arduino() function. Change the line as needed.

self.board = pyfirmata.Arduino(str("COM5"))

Arduino should run the standard firmata code to communicate with pyfirmata library in python. Open Arduino IDE, select the board and COM port. In newer versions of the Arduino IDE, this code is available here: https://github.com/firmata/arduino/blob/53bb550d704ff9db76c01286c97a0f5c14321e49/examples/StandardFirmata/StandardFirmata.ino

Upload this code from the examples to the board.
Arduino

In your pyfirmata install folder, change a line in this python script:

C:\Users\WG30Lab\AppData\Local\Packages\PythonSoftwareFoundation.Python.3.11_qbz5n2kfra8p0\LocalCache\local-packages\Python311\site-packages\pyfirmata\pyfirmata.py

Change line 185 to:

len_args = len(inspect.getfullargspec(func)[0])

Other hardcoded items in the code

Stages are setup such that when you are looking at the block face, y is positive going up and x is positive going left.
If this changes, then the tiling will not work as expected.

Assume that sectioning is always at 3 microns. If not, change this line in main.py.

z_thickness = 3 * (skipEvery + 1)

Assume that the limits for the X and Y stages are fixed. If this changes, change these lines in main.py

x_stage_max = 25400
y_stage_max = 20000

Assume that one sectioning cycle takes less than 25 seconds to complete. If not, change these lines with an appropriate time.

imaging_module.py (three places)

if time.time() - self.last_cutting_time > 25:
  break


trimming_module.py (one place)

if time.time() - last_cutting_time > 25:
  break

Assume that the overlap between tiles is exactly 20%

stitching_module.py (line 59)

        # Check that the xy_positions are properly set (assuming 20% overlap)
        for index in range(xy_positions_sorted.shape[0]):
            if (xy_positions_sorted[index, 0] % (tile_size_x * 0.8 * self.pixel_size)) != 0:
                print('Did not see tiles at 20 percent overlap')
                return None
            
            if (xy_positions_sorted[index, 1] % (tile_size_y * 0.8 * self.pixel_size)) != 0:
                print('Did not see tiles at 20 percent overlap')
                return None

Running the software

Go to bin\ folder and run the batch script 3D-MUSE-acquire.bat

  • It will start a command window, do not close that at any time when using the application.

Software screenshot

3D-MUSE-acquire software

Getting help

The Help tab > Instructions button on the application's taskbar has useful information on how to use the software. It has information on how to keep a block in the microtome, how to clean the knife, how to set up a trimming cycle, how to do an imaging cycle, how to stop in between handling error situations and how to shutdown the system. The text below is all available from Help > Instructions button in the software.

Setting up the microtome prior to initialization

  1. Ensure that the microtome is in the 3D mode by following the steps in the microtome user manual. The cut mode of the microtome should be set to single. Set the section thickness to 3 microns and the cutting speed to the first black line on the dial (corresponds to 0.5). The cutting angle of the knife should be 4 degrees.
  2. Clamp the tissue block into the sample holder with the pointed edge oriented towards the knife. Tighten the vice clamp. If desired, the knife guard can be used to ensure that the knife does not touch the skin. After the block is clamped, the knife guard can be opened.
  3. Retract the sample away from the knife edge. Next, carefully advance the sample forward towards the knife such that the sample is close to the knife edge but does not touch it. You should ensure that there is a visible gap by eye between the knife edge and the sample. The handwheel on the microtome is always turned clockwise.
  4. Clean the edge of the knife using a brush to ensure that it is free of debris. Use a styrofoam stick and knife cleaning fluid to wipe any additional debris on the knife. The stick should be held at an angle of 45 degrees and gently moved over the knife. Do not apply too much pressure as this may damage the knife. Always keep track of knife usage as knives are changed in the system. IMPORTANT: It is advised to either move the knife to a fresh edge or place a new knife every 2-3 samples (10,000 to 15,000 cuts).
  5. Ensure that the fan is properly aligned towards the block. This is required to remove sections sticking to the block surface after a cut. A vibration isolation pad is used to reduce vibrations from the fan on to the imaging system. The fan speed is set to 1.

Setting up the imaging system prior to initialization

  1. Switch on the power supply to the light source and the motorized XYZ stages. Connect the USB cables for the camera and Arduino to their designated slots on the acquisition computer. USB connections from the XYZ stages are always connected to the computer. CAUTION: When the Arduino is connected to the computer, the digital pins are reset (go from high to low), which will cause a cutting cycle to occur. It is thus important to pull the sample block away from the knife initially to ensure that the knife is not damaged.
  2. Open MicroManager and choose the pycromanager.cfg configuration file. This will launch the MicroManager window.
  3. If not already done, run the 3D-MUSE-acquire software. It is available as a batch script on the desktop or can be run if the software repository is set up in Visual Studio Code. You are already running it if you are seeing this in the Help > Instructions tab.
  4. Click the initialize Arduino button. This will establish the connection between the python acquisition software and the Arduino. When done, the initialize Arduino button will be greyed out since you need to do this only once per run of the software. CAUTION: This operation will also reset the digital pins on the Arduino (go from high to low), which will cause a cutting cycle to occur. It is thus important to pull the sample block away from the knife initially to ensure that the knife is not damaged. If cutting was occurring previously, this will cause one section to be cut.
  5. If the XYZ stages were rebooted, it is necessary to home the stages to their zero positions. Press the home stages button. This operation will take a while, but when done, the home stages button will be greyed out.

Steps for trimming

  1. When a resin block is placed on the microtome, the block may need to be sectioned first to expose the nerve surface. We refer to this process as trimming.
  2. Enter the desired folder location for storing the image stack. A log file will be created in this location during the session with useful debug information.
  3. Enter the number of cuts desired in the corresponding text box. Each cut will be 3 µm thick, unless the sectioning thickness was changed on the microtome control panel. Thus, if 1 mm of the sample needs to be cut, enter 333 cuts. Ensure that the switch on light source checkbox is off. CAUTION: Do not provide more cuts than what is physically possible. It is useful to measure the length of the block with a scale and ensure that the cutting does not extend into the yellow resin portion of the block.
  4. Ensure that the trim the block – do not collect images checkbox is checked. Other properties in the acquisition window are not relevant for trimming and will be disregarded.

Steps for imaging

  1. We will set up tiles for imaging prior to running an imaging session. The tile set up is done primarily in Micromanager software. However, we set the exposure time text box in the acquisition software to a suitable value, around 200 ms.
  2. Click the Live button in Micromanager to open a live view window, displaying the current image from the camera. An additional window labeled “Inspect-Preview” is also shown with the histogram of the current image. Click on the full scale button to ensure that the live view is mapping the image intensities correctly.
  3. Open the Stage control window in Micromanager. Use the stage window to move around the sample, changing the move step sizes on the stage window if required. There are three step sizes available (>, >>, >>>). Each arrow can be configured to take a step of a certain distance. Do not change the X and Y distances for the field with three arrows (>>>) unless the objective lens has been changed. This is because these numbers are important when setting up tiles. When using tiles with 20% overlap, the distance in the >>> field should be 2800 µm in X and 2100 µm in Y for the 4x objective. For the 10x objective, it should be 1100 µm in X and 888 µm in Y.
  4. When panning around the sample to view the nerve, ensure that the switch on light source checkbox is selected (this is the only case when you need to check this box manually, an imaging session will automatically switch the light source on and off as required).
  5. The image can be window/leveled if the brightness is not optimal. The window level and gamma settings are available directly on the histogram in the Inspect Preview window. If the brightness is too high, the exposure can be reduced to 100 ms. In general, blocks are usually brighter in the center than at the edge, so it is not an issue if the first image is slightly dark, and the histogram is primarily in the lower half. Intensity normalization methods can be applied later if desired.
  6. To set up tiles, open the Multi D acquisition tab in MicroManager, and select Edit Position list. Open the stage control window as well if not already open. Pan around the sample and focus on the block as desired. If the sample is not visible, you may need to run another trimming session. Moving along the Z stage will help with focusing.
  7. If nerve is completely visible (full cross-section), use the create grid option in the Edit Position list window. There is a box that says overlap, change it from um (default) to %. Set the overlap to 20%, ensure the pixel size is correct (0.9 µm if you are using the 4x objective, 0.37 µm if you are using the 10x objective). If they are incorrect, these values can be changed in Objective configuration and preset Objective-A (4x) and Objective-B (10x) in the main window of MicroManager.
  8. In the Create Grid window, set the individual corners as desired. The step distance with the >>> in the stage window is now useful, since one step by >>> will move the stage by amount that is slightly less than a tile (80%). This will let you set up perfect tiles (one >>> step in X and one >>> step in Y and setting the appropriate top, left, bottom and right corners will result in the creation of a 2x2 grid). As described earlier, for the 4x objective, this distance >>> should be 2800 µm in X and 2100 µm in Y. For 10x objective, it should be 1100 µm in X and 888 µm in Y. IMPORTANT: When setting up tiles, make sure that the tiles will be sufficient for the full length of the nerve. For example, if the nerve is oriented such that it moves downward in the block, it may be useful to set up 2 tiles in the Y direction and 1 tile in X direction.
  9. Select OK on the grid creator window, now you should see positions populate in the MDA window. Click the go to button after selecting each tile position and focus using the Z stage control as required. Click the Merge button and then the Merge with current Stage position. This will ensure that each tile is set up with the best focus position. Save the positions to a file with a suitable name in the same directory as the storage directory. If the first image acquisition is to be captured, save the file as PositionList_1.pos. If 3 acquisitions are already captured in the folder, save the file as PositionList_4.pos. This will ensure easy loading of positions later if required. This may be needed if the python acquisition software closes due to an error and the acquisition does not change to Finished in Micromanager. MicroManager and the acquisition software would need to be restarted in that case, and having the position list saved to a file is extremely useful to ensure the same tile setup between runs.
  10. Ensure that the correct objective magnification is selected from the dropdown box in the acquisition software. Two objective options are currently provided, 4x and 10x. MicroManager should automatically recognize the correct pixel sizes to use.
  11. Set number of cuts as desired. If stitching is needed, it will be done automatically and saved in a separate directory in the same storage folder. CAUTION: Do not provide more cuts than what is physically possible. It is useful to measure the length of the block with a scale and ensure that the cutting does not extend into the yellow resin portion of the block.
  12. If desired, an autofocus algorithm can be run at intermediate slices. Add an appropriate value to that line item. Usually autofocus every 5 images is sufficient. If the value is set to zero autofocus is not performed, if the value is 1 autofocus is done on all images.
  13. Images can be skipped between sections. Add an appropriate value in the corresponding text box. If 0, no images are skipped. In general, if every fifth slice needs to be imaged, the skip image option can be set to four.
  14. If desired a z-stack can be setup at each tile. This is suitable when working with an objective with a low depth of focus, e.g, 10x 0.45 NA. Individual slices in a z-stack are automatically stitched and merged into a single image. If Z start is set to -3, Z stop is set to 3, and Z step is set to 1, the software will collect images at z-3, z-2, z-1, z, z+1, z+2, and z+3 microns. The seven resultant images will be stitched to create a single image. This algorithm is currently being implemented, so please set these three values to zeros for now.
  15. Uncheck switch on light source and trim the block – do not collect images options.
  16. Stop the live view in micromanager.
  17. Click start acquisition button. A progress bar and status message box will be updated during each cutting and imaging event.

Stopping and restarting imaging

For trimming and acquisition cycle, the stop acquisition button will work to stop the session. It will be noted in the log file as to how many cuts were taken. If there is an error in the program, this software may shut down. You can relaunch the software and try running again. If the block was being imaged when this software crashes, the acquisition window displaying the images in MicroManager may say "(Running)" in the top left bar of the acquisition window. In tha case, Micromanager would need to be closed and restarted. You will need to set the tile positions again in the Multi D acquisition window. It is easy to load in the position file again if you saved it earlier. There is no "pause" option in the software. You stop and start acquisition as desired. To shutdown, switch off microtome, cover the knife guard. Switch off power supply to xyz stages and light source. Disconnect the arduino and camera cables. Close this software and turn off PC.

IMPORTANT: When imaging is complete, upload the full storage directory to Globus/NAS as needed. The imaging PCs are not meant to be where the data is stored long term.

Troubleshooting issues

If you see that the imaging PC is sending a cut signal (the cutting light on the relay board keeps going on and off), but the microtome is not actually cutting, it could be one of the following issues:

  1. The specimen chuck may be at its most forward position and cannot move any further. Refer to the Nanocut user manual (page 43, figure 21, label number 5). Check to make sure that the button on the microtome's control panel that represents the coarse feed forward move (two arrows) does not have its yellow LED lit up.
  2. Ensure that the M-STOP button on the microtome is not yellow. It could be due to the lever under the handwheel being in the wrong position or the handwheel itself being locked.
  3. If the microtome has hit a hard object, it may have tripped the fuse. It is on the back of the microtome as a black button on the right, you may need to push it back in if it is out.
  4. The microtome should not be in the emergency stop (E-STOP) mode.

Viewing the image datasets in Fiji

Install Fiji
https://imagej.net/software/fiji/downloads

Run Fiji

If you are viewing just a single tile stack, you can drag and drop in Fiji

Follow steps below to view stitched data (in a zarr folder)

Go to Help>Update...

In the ImageJ updater dialog, click on Manage update sites.

The MoBIE plugin should already be listed. Select it and click Close.

Click Apply changes to install it.

Now use the search window in Fiji and type Zarr and click the Open OME-Zarr From File System command (File system)
zarr-1

Browse to the folder location e.g., MUSE_stitched_acq_1.zarr

Check to make sure that the zarr folder has a .zattrs file in it. The size of the folder should not be at least a few MBs (one image, one tile).
zarr-2

This will open the BigDataViewer which will show the full dataset.

Information on how to use the bigdataviewer is available in the first half of this video.
https://www.youtube.com/watch?v=EApotxnnQD8