19 changes: 16 additions & 3 deletions content/docs/csidriver/installation/helm/powerstore.md
Original file line number Diff line number Diff line change
Expand Up @@ -22,7 +22,7 @@ The node section of the Helm chart installs the following component in a _Daemon
The following are requirements to be met before installing the CSI Driver for Dell EMC PowerStore:
- Install Kubernetes or OpenShift (see [supported versions](../../../../csidriver/#features-and-capabilities))
- Install Helm 3
- If you plan to use either the Fibre Channel or iSCSI protocol, refer to either _Fibre Channel requirements_ or _Set up the iSCSI Initiator_ sections below. You can use NFS volumes without FC or iSCSI configuration.
- If you plan to use either the Fibre Channel, iSCSI or NVMe protocol, refer to either _Fibre Channel requirements_, _Set up the iSCSI Initiator_ or _Set up the NVMe Initiator_ sections below. You can use NFS volumes without FC or iSCSI configuration.
> You can use either the Fibre Channel or iSCSI protocol, but you do not need both.

> If you want to use preconfigured iSCSI/FC hosts be sure to check that they are not part of any host group
Expand Down Expand Up @@ -61,6 +61,19 @@ To do this, run the `systemctl enable --now iscsid` command.

For information about configuring iSCSI, see _Dell EMC PowerStore documentation_ on Dell EMC Support.


### Set up the NVMe Initiator
The CSI Driver for Dell EMC Powerstore 2.2 and higher support NVMe connectivity.

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Remove any occurrence of EMC.


If you use the NVMe/TCP protocol, set up the NVMe initiators as follows:
- Ensure that the NVMe initiators are available on the controller and node pods.
- Kubernetes nodes must have access (network connectivity) to an NVMe port on the Dell EMC Powerstore array that
has NVMe/TCP IP interfaces.
- We require the NVMe management command line interface (nvme-cli) to configure, edit, view, or start the NVMe client and target.
You can install nvme-cli by running `apt install nvme-cli` on Ubuntu and `yum install nvme-cli` on Rhel/CentOS.
- Modules including the nvme, nvme_core, nvme_fabrics, and nvme_tcp are required for using NVMe over Fabrics using TCP
The modules can be loaded using `modprobe nvme` and `modprobe nvme_tcp`.

### Linux multipathing requirements
Dell EMC PowerStore supports Linux multipathing. Configure Linux multipathing before installing the CSI Driver for Dell EMC
PowerStore.
Expand Down Expand Up @@ -139,7 +152,7 @@ CRDs should be configured during replication prepare stage with repctl as descri
- *username*, *password*: defines credentials for connecting to array.
- *skipCertificateValidation*: defines if we should use insecure connection or not.
- *isDefault*: defines if we should treat the current array as a default.
- *blockProtocol*: defines what SCSI transport protocol we should use (FC, ISCSI, None, or auto).
- *blockProtocol*: defines what SCSI transport protocol we should use (FC, ISCSI, NVMETCP, None, or auto).
- *nasName*: defines what NAS should be used for NFS volumes.

Add more blocks similar to above for each PowerStore array if necessary.
Expand Down Expand Up @@ -206,7 +219,7 @@ There are samples storage class yaml files available under `samples/storageclass
allowedTopologies:
- matchLabelExpressions:
- key: csi-powerstore.dellemc.com/12.34.56.78-iscsi
# replace "-iscsi" with "-fc" or "-nfs" at the end to use FC or NFS enabled hosts
# replace "-iscsi" with "-fc", "-nvme" or "-nfs" at the end to use FC, NVME, or NFS enabled hosts
# replace "12.34.56.78" with PowerStore endpoint IP
values:
- "true"
Expand Down