SMA SI/STP-SE: fix forced battery charging #15477

Merged
merged 1 commit into from
Aug 19, 2024
Merged

SMA SI/STP-SE: fix forced battery charging #15477

merged 1 commit into from
Aug 19, 2024

Conversation

premultiply
Copy link
Member

@premultiply premultiply commented Aug 18, 2024

Fixes #15294, #15442

...after SMA repaired their SHM firmware.

@premultiply premultiply added bug Something isn't working devices Specific device support labels Aug 18, 2024
@wittmannchris
Copy link
Sponsor

Prinzipiell kann das ja jetzt schon rein oder , denn :

  1. jemand hat noch die alte FW -> kein Änderung
  2. Jemand hat die beschädigte FW -> geht eh nicht
  3. Jemand hat die Feldtest FW, welche bald gepusht wird -> läuft dann wieder.

Egal wie, stört also aktuell niemand, sobald der rollout stattfindet läufts aber denn gleich

@andig
Copy link
Member

andig commented Aug 19, 2024

Könnt ihr die Änderung erklären? MinInt wäre ja der alte Wert?

@andig andig merged commit ede4259 into master Aug 19, 2024
6 checks passed
@andig andig deleted the fix/sma-bat-charge branch August 19, 2024 07:40