Expand Up @@ -55,6 +55,6 @@ Validity:
* The tube bundles used in the experimental investigations had transverse and longitudinal pitch ratios as follows:
* In the range Re < 10E3: For in-line tube arrangement: a x b = 1:25 x 1:25; 1:5 x 1:5; 2:0 x 2:0. For staggered tube arrangement: a x b = 1:25 x 1:0825; 1:5 x 1:299; 1:768 x 0:884.
* In the range Re ≥ 10E3: For in-line tube arrangement: 1:25 ≤ a ≤ 3:0; 1:2 ≤ b ≤ 3:0. For staggered tube arrangement: 1:25 ≤ a ≤ 3:0; 0:6 ≤ b ≤ 3:0; c ≥ 1:25.

Citation: VDI. VDI Heat Atlas. Berlin, Heidelberg: VDI-Buch-Springer, 2010. Chapter L1
Output:
- Pressure Drop in kPa