It's not currently set up to do that but it might be possible. What brand and model are the inverters? |
Thanks for getting back to me. The inverters are 2 x Solis S5-EH1P3.6K-L. Tbh wish I had a single larger inverter for simplicity, but was told at the time a twin install offered benefits. I suspect it was just that larger inverters weren't in stock back then. I have the inverters communicating with HA via wills106/homeassistant-solax-modbus. Managed to install Solcast via BJReplay. Think I will get going using simple automations as suggested by GordonMarkus. My knowledge of HA very much at entry level! |
I’d be interested to see if this works also - I have two 5kWh batteries and
a single solis inverter, however can only push 3.6kw to the house at a
time, so high power items (showers etc) would utilise more PV power if I
had two on the go.
Cheers,
P
…On Fri, 7 Jun 2024 at 12:28, neilrfuller ***@***.***> wrote:
Thanks for getting back to me. The inverters are 2 x Solis S5-EH1P3.6K-L.
Tbh wish I had a single larger inverter for simplicity, but was told at the
time a twin install offered benefits. I suspect it was just that larger
inverters weren't in stock back then. I have the inverters communicating
with HA via wills106/homeassistant-solax-modbus. Managed to install Solcast
via BJReplay. Think I will get going using simple automations as suggested
by GordonMarkus. My knowledge of HA very much at entry level!
—
Reply to this email directly, view it on GitHub
<#239 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AHMEIQYPW62U366EHUTWJLDZGGKOZAVCNFSM6AAAAABI4TVGCKVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCNJUGY2DIMBWGE>
.
You are receiving this because you are subscribed to this thread.Message
ID: ***@***.***>
|
If free to choose again, I don't think I would go down the twin inverter route. I have a separate CT clamp for each inverter. I suspect that really an EPM (Export Power Monitor) should have been fitted to balance the inverters. |
Stale issue message |
Hi, I have a system with twin 3.6kW inverters each with 4kW of panels. Could you advise me if pv_opt can handle multiple inverters, or would I need 2 instances. Many thanks.