This project aims to charge the battery pack of a photovoltaic system when the energy rates are as low as possible.
The program continuously runs and does the following:
It queries the Tibber API for the least expensive energy rates (= price minimum).
- This is done in the TibberAPIHandler.
- The program then runs from a minimum in prices to the next one and sleeps in between.
When the current time is a price minimum, the program wakes up and does the following:
- Check for the expected power consumption until the next price minimum.
- This is done in the SemsPortalApiHandler.
- The inverter used while programming this is a model from Goodwe (
GW5KN-ET
) which sends its data (state of charge, power input, power output, ...) into the SEMS portal. These values are retrieved from there via the API. - The program calculates how much power will be used until the next price minimum. This is done based on the duration until then, how much power is used during the day vs. during the night and the power consumption in the last 7 days.
- Check for the amount of expected power harvested by the sun until the next price minimum.
- This is done in the SunForecastHandler.
- The data about the photovoltaic system is used to query https://forecast.solar/ via their API for an estimate of power production during the day.
- The program calculates how much power will be harvested until the next price minimum. This is done based on the duration until then, the amount of sun until then and the overlapping of the timeframes (duration until next minimum vs. sun shining only during the day).
- Check the amount of power currently remaining in the battery.
- This is done in the SemsPortalApiHandler.
- Check the amount of power supposed to be remaining in the battery when reaching the next price minimum.
- This is (as many other values) defined in
.env
. More explanation on this can be found below.
- This is (as many other values) defined in
- Calculate the difference between these values.
- Charge the battery (if necessary) such that reaching the next price minimum is possible.
- This is (as well as the main loop) is done in the InverterChargeController.
- If charging is necessary, the code calculates the target state of charge, sets the inverter controller accordingly and checks the battery status every 5 minutes.
- If no charging is needed, the program will do nothing.
- Afterwards, the program will go back to sleep until the next price minimum.
This is an example excerpt from the log and shows the inner workings
[2024-10-29T23:00:00+0100] [InverterChargeController] [INFO] Waiting is over, now is the a price minimum. Checking what has to be done to reach the next minimum...
[2024-10-29T23:00:00+0100] [TibberAPIHandler] [DEBUG] Finding the price minimum...
[2024-10-29T23:00:00+0100] [TibberAPIHandler] [DEBUG] Crawling the Tibber API for the electricity prices
[2024-10-29T23:00:00+0100] [TibberAPIHandler] [DEBUG] The Upcoming energy rates are [0.3085 € at 2024-10-30 00:00:00+01:00, 0.3082 € at 2024-10-30 01:00:00+01:00, 0.3054 € at 2024-10-30 02:00:00+01:00, 0.3053 € at 2024-10-30 03:00:00+01:00, 0.3083 € at 2024-10-30 04:00:00+01:00, 0.3151 € at 2024-10-30 05:00:00+01:00, 0.3356 € at 2024-10-30 06:00:00+01:00, 0.3548 € at 2024-10-30 07:00:00+01:00, 0.3539 € at 2024-10-30 08:00:00+01:00, 0.3366 € at 2024-10-30 09:00:00+01:00, 0.3255 € at 2024-10-30 10:00:00+01:00, 0.3191 € at 2024-10-30 11:00:00+01:00, 0.3106 € at 2024-10-30 12:00:00+01:00, 0.3159 € at 2024-10-30 13:00:00+01:00, 0.3211 € at 2024-10-30 14:00:00+01:00, 0.3388 € at 2024-10-30 15:00:00+01:00, 0.379 € at 2024-10-30 16:00:00+01:00, 0.4193 € at 2024-10-30 17:00:00+01:00, 0.4182 € at 2024-10-30 18:00:00+01:00, 0.3784 € at 2024-10-30 19:00:00+01:00, 0.3476 € at 2024-10-30 20:00:00+01:00, 0.3346 € at 2024-10-30 21:00:00+01:00, 0.3259 € at 2024-10-30 22:00:00+01:00, 0.3223 € at 2024-10-30 23:00:00+01:00]
[2024-10-29T23:00:00+0100] [TibberAPIHandler] [DEBUG] Found 0.3548 € at 2024-10-30 07:00:00+01:00 to be the first maximum of the upcoming energy rates
[2024-10-29T23:00:00+0100] [TibberAPIHandler] [DEBUG] Found 0.4193 € at 2024-10-30 17:00:00+01:00 to be the second maximum of the upcoming energy rates
[2024-10-29T23:00:00+0100] [TibberAPIHandler] [DEBUG] Found 0.3106 € at 2024-10-30 12:00:00+01:00 to be the global minimum of the energy rates between the first and second maximum
[2024-10-29T23:00:00+0100] [InverterChargeController] [INFO] The next price minimum is at 2024-10-30 12:00:00+01:00
[2024-10-29T23:00:00+0100] [SunForecastHandler] [DEBUG] Getting estimated solar output between 2024-10-29 23:00:00.000215+01:00 and 2024-10-30 12:00:00+01:00
[2024-10-29T23:00:00+0100] [SunForecastHandler] [DEBUG] Sunrise is at 2024-10-29 07:10:00+01:00, sunset is at 2024-10-29 17:10:00+01:00, duration of sunlight is 10:00:00, offset is 1:00:00, sunrise with offset is at 2024-10-29 08:10:00+01:00, sunset with offset is at 2024-10-29 16:10:00+01:00
[2024-10-29T23:00:00+0100] [SunForecastHandler] [INFO] There is 0:00:00 of sunlight (with 10 % offsets) during the given timeframe
[2024-10-29T23:00:00+0100] [InverterChargeController] [INFO] The expected energy harvested by the sun till the next price minimum is 0 Wh
[2024-10-29T23:00:00+0100] [SemsPortalApiHandler] [DEBUG] Getting estimated energy usage between 2024-10-29 23:00:00.000215+01:00 and 2024-10-30 12:00:00+01:00
[2024-10-29T23:00:00+0100] [SemsPortalApiHandler] [DEBUG] The time between the given timeframe is split across 6:00:00 of daytime and 6:59:59.999785 of nighttime
[2024-10-29T23:00:00+0100] [SemsPortalApiHandler] [DEBUG] Determining average energy consumption per day
[2024-10-29T23:00:00+0100] [SemsPortalApiHandler] [DEBUG] Logging in into the SEMSPORTAL...
[2024-10-29T23:00:03+0100] [SemsPortalApiHandler] [DEBUG] Login successful
[2024-10-29T23:00:03+0100] [SemsPortalApiHandler] [DEBUG] Crawling the SEMSPORTAL API for energy consumption data...
[2024-10-29T23:00:05+0100] [SemsPortalApiHandler] [DEBUG] Extracted last weeks energy usage: [6280 Wh, 7260 Wh, 5980 Wh, 10110 Wh, 1690 Wh, 4420 Wh, 2920 Wh]
[2024-10-29T23:00:05+0100] [SemsPortalApiHandler] [DEBUG] Expected energy usage of the day is 5522 Wh
[2024-10-29T23:00:05+0100] [SemsPortalApiHandler] [DEBUG] Average power consumption today is 230 W
[2024-10-29T23:00:05+0100] [SemsPortalApiHandler] [INFO] Energy usage during daytime is expected to be 1656 Wh, energy usage during nighttime is expected to be 1288 Wh
[2024-10-29T23:00:05+0100] [InverterChargeController] [INFO] The total expected energy usage till the next price minimum is 2945 Wh
[2024-10-29T23:00:05+0100] [SemsPortalApiHandler] [DEBUG] Crawling the SEMSPORTAL API for current state of charge...
[2024-10-29T23:00:05+0100] [SemsPortalApiHandler] [DEBUG] Logging in into the SEMSPORTAL...
[2024-10-29T23:00:06+0100] [SemsPortalApiHandler] [DEBUG] Login successful
[2024-10-29T23:00:06+0100] [InverterChargeController] [INFO] The battery is currently at 53 %, thus it is holding 3763 Wh
[2024-10-29T23:00:06+0100] [InverterChargeController] [INFO] The battery shall contain 1420 Wh (20 %) when reaching the next minimum
[2024-10-29T23:00:06+0100] [InverterChargeController] [DEBUG] Summary of energy values: {'timestamp now': '2024-10-29 23:00:00.000215+01:00', 'next price minimum': '2024-10-30 12:00:00+01:00', 'expected power harvested till next minimum': 0 Wh, 'expected energy usage till next minimum': 2945 Wh, 'current state of charge': 53, 'current energy in battery': 3763 Wh, 'target min state of charge': 20, 'energy to be in battery when reaching next minimum': 1420 Wh}
[2024-10-29T23:00:06+0100] [InverterChargeController] [INFO] There is a need to charge 602 Wh
[2024-10-29T23:00:06+0100] [InverterChargeController] [INFO] Need to charge to 61 % in order to reach the next minimum with 20 % left
[2024-10-29T23:00:06+0100] [SemsPortalApiHandler] [INFO] Determining amount of energy bought today
[2024-10-29T23:00:06+0100] [SemsPortalApiHandler] [DEBUG] Logging in into the SEMSPORTAL...
[2024-10-29T23:00:06+0100] [SemsPortalApiHandler] [DEBUG] Login successful
[2024-10-29T23:00:06+0100] [SemsPortalApiHandler] [DEBUG] Crawling the SEMSPORTAL API for energy consumption data...
[2024-10-29T23:00:07+0100] [InverterChargeController] [DEBUG] The amount of energy bought before charging is 2230 Wh
[2024-10-29T23:00:07+0100] [InverterChargeController] [INFO] Starting to charge
[2024-10-29T23:00:07+0100] [Inverter] [DEBUG] Setting new operation mode: ECO_CHARGE...
[2024-10-29T23:00:12+0100] [Inverter] [DEBUG] Getting current operation mode...
[2024-10-29T23:00:13+0100] [Inverter] [INFO] Current Operation mode is ECO_CHARGE
[2024-10-29T23:00:13+0100] [Inverter] [INFO] Successfully set new operation mode ECO_CHARGE
[2024-10-29T23:00:13+0100] [InverterChargeController] [INFO] Set the inverter to charge, the target state of charge is 61 %. Checking the charging progress every 0:10:00...
[2024-10-29T23:10:13+0100] [SemsPortalApiHandler] [DEBUG] Crawling the SEMSPORTAL API for current state of charge...
[2024-10-29T23:10:13+0100] [SemsPortalApiHandler] [DEBUG] Logging in into the SEMSPORTAL...
[2024-10-29T23:10:13+0100] [SemsPortalApiHandler] [DEBUG] Login successful
[2024-10-29T23:10:14+0100] [InverterChargeController] [INFO] The current state of charge is 58%
[2024-10-29T23:10:14+0100] [InverterChargeController] [DEBUG] Charging is still ongoing (current: 58%, target: >= 61%) --> Waiting for another 0:10:00...
[2024-10-29T23:20:14+0100] [SemsPortalApiHandler] [DEBUG] Crawling the SEMSPORTAL API for current state of charge...
[2024-10-29T23:20:14+0100] [SemsPortalApiHandler] [DEBUG] Logging in into the SEMSPORTAL...
[2024-10-29T23:20:14+0100] [SemsPortalApiHandler] [DEBUG] Login successful
[2024-10-29T23:20:15+0100] [InverterChargeController] [INFO] The current state of charge is 67%
[2024-10-29T23:20:15+0100] [InverterChargeController] [INFO] Charging finished (67%) --> Setting the inverter back to normal mode
[2024-10-29T23:20:15+0100] [Inverter] [DEBUG] Setting new operation mode: GENERAL...
[2024-10-29T23:20:16+0100] [Inverter] [DEBUG] Getting current operation mode...
[2024-10-29T23:20:16+0100] [Inverter] [INFO] Current Operation mode is GENERAL
[2024-10-29T23:20:16+0100] [Inverter] [INFO] Successfully set new operation mode GENERAL
[2024-10-29T23:20:16+0100] [SemsPortalApiHandler] [INFO] Determining amount of energy bought today
[2024-10-29T23:20:16+0100] [SemsPortalApiHandler] [DEBUG] Logging in into the SEMSPORTAL...
[2024-10-29T23:20:17+0100] [SemsPortalApiHandler] [DEBUG] Login successful
[2024-10-29T23:20:17+0100] [SemsPortalApiHandler] [DEBUG] Crawling the SEMSPORTAL API for energy consumption data...
[2024-10-29T23:20:18+0100] [InverterChargeController] [DEBUG] The amount of energy bought after charging is 3320 Wh
[2024-10-29T23:20:18+0100] [InverterChargeController] [INFO] Bought 1090 Wh to charge the battery
[2024-10-29T23:20:18+0100] [InverterChargeController] [INFO] The next price minimum is at 2024-10-30 12:00:00+01:00. Waiting until then...
-
Create a virtual environment
python -m venv .venv
-
Activate the virtual environment
source .venv/bin/activate
-
Install the requirements
poetry install
-
Create an
.env
and fill in your valuescp .env.example .env vi .env
Variable Name Description Default Value Possible Values ERROR_MAIL_ADDRESS
The mail address to send error logs to in error_mailer.sh. Only necessary if script is used. - A string containing an email address, example username@domain.tld
DRY_RUN
Do not actually change the operation mode of the inverter (for testing purposes). True
[ True
,False
]USE_DEBUG_SOLAR_OUTPUT
Use a debug value for the expected solar output (can be used while debugging since the solar forecast API offers a very limited amount of API calls per day). Should be set to False
in normal production mode.False
[ True
,False
]LOGLEVEL
The level to log at. INFO
[ TRACE
,DEBUG
,INFO
,WARNING
,ERROR
,CRITICAL
]DIRECTORY_OF_LOGS
The directory where the logs of the application shall be stored. Ensure the user running the application has permissions to write in this directory. <path to repository>/logs/
A string containing an absolute path, example: /var/log/inverterchargecontroller/
PRINT_TO_STDOUT
Whether to print to stdout in addition to the logfile. True
[ True
,False
]POWER_USAGE_FACTOR
The amount of power used during the day vs during the night as a percentage value. E.g. if the value is set to 0.6
the program assumes you use 60 % of the daily power usage between 6 AM and 6 PM and 40 % between 6 PM and 6 AM.0.6
A decimal number between 0
and1
, typically between0.5
and0.8
TIBBER_API_TOKEN
The token to crawl the Tibber API. See https://developer.tibber.com/docs/guides/calling-api for more information. - A string, example: my-secret-token
INVERTER_HOSTNAME
The hostname or IP of the inverter. - [ inverter.mydomain.com
,192.168.5.10
, ...]INVERTER_BATTERY_CAPACITY
The capacity of the battery in watt hours without any separators. - A number, typically between 3000
and15000
INVERTER_TARGET_MIN_STATE_OF_CHARGE
The state of charge the battery shall have when reaching the next minimum as a buffer. 20
A number between 0
and100
, typically between0
and40
INVERTER_MAX_TARGET_SOC
The maximum state of charge the inverter will charge to since the last few percent take a long time to charge. 90
A number between 0
and100
, typically between80
and100
SEMSPORTAL_USERNAME
The username to login into the SEMSPortal. - A string, example: mail@mydomain.com
SEMSPORTAL_PASSWORD
The password to login into the SEMSPortal. - A string, example: my-secret-password
SEMSPORTAL_POWERSTATION_ID
The ID of the inverter in the SEMSPortal. This can be found at the end of the URL in the browser after logging in. - A string, example: aaaaaaaa-bbbb-cccc-dddd-eeeeeeeeeeee
SOLCAST_API_KEY
The API-Key of https://www.solcast.com/ - A string, example: my-secret-token
ROOFTOP_ID_1
The ID of the rooftop in solcast. - A string, example: aaaa-bbbb-cccc-dddd
ROOFTOP_ID_2
The ID of the second rooftop in solcast. This can be used if you have solar panels on both sides of your roof or a small balcony power plant, can be omitted if unused. - A string, example: aaaa-bbbb-cccc-dddd
LOCATION_LATITUDE
See https://doc.forecast.solar/api:estimate#url_parameters for an explanation. - A string, example: 48.8778244909298
LOCATION_LONGITUDE
See https://doc.forecast.solar/api:estimate#url_parameters for an explanation. - A string, example: 2.3321814528287352
LOCATION_HEIGHT
The height of your property relative to sea level (only used for sunrise and sunset calculation, not that important). 0
A number greater or equal to 0
PANELS_PACK2_INSTALLED
Whether there is a second solar array installed. This can be used if you have solar panels on both sides of your roof or a small balcony power plant. If this set to True
you have to set all the...PACK2...
values.False
[ True
,False
]PANELS_PACK1_PLANE_DECLINATION
andPANELS_PACK2_PLANE_DECLINATION
See https://doc.forecast.solar/api:estimate#url_parameters for an explanation. - A number between 0
and90
PANELS_PACK1_PLANE_AZIMUTH
andPANELS_PACK2_PLANE_AZIMUTH
See https://doc.forecast.solar/api:estimate#url_parameters for an explanation. - A number between -180
and180
PANELS_PACK1_NUMBER_OF_PANELS
andPANELS_PACK2_NUMBER_OF_PANELS
The number of installed solar panels. - A number, typically between 5
and50
.PANELS_PACK1_MAXIMUM_POWER_OUTPUT_PER_PANEL
andPANELS_PACK2_MAXIMUM_POWER_OUTPUT_PER_PANEL
The maximum power output per solar panel in watts. - A number, typically between 100
and600
.ABSENCE_TIMEFRAME
This variable CAN be set in order to set a timeframe for an absence. During the absence the value of ABSENCE_POWER_CONSUMPTION
is used to determine the power consumption (not the average of the last week). The timestamps have to be in ISO8601 format and contain a timezone.- A string in the format <START_OF_ABSENCE>;<START_OF_ABSENCE>
. Example:2024-11-03T00:00:00+0100;2024-11-10T11:00:00+0100
ABSENCE_POWER_CONSUMPTION
The power consumption to use during the absence (instead of lass week's average) 150
A number, typically between 0
and250
.All the environment variables are read in every time they are used. As a consequence, the program does not have to be restarted when they are altered.
You can run the program manually
python3 source/main.py
or you can install the program as a systemd service.
Before installing the systemd service, you can optionally choose to create a user whose sole purpose is to run this application. This is not necessary at all but considered best practice. If you choose to run the application as your own user, skip this step.
sudo su
useradd -r -s /usr/sbin/nologin -m <username>
cd /home/<username>
git clone https://github.com/felixschndr/InverterChargeController.git app/
cd app/
python -m venv .venv
source .venv/bin/activate
poetry install
cp .env.example .env
vi .env
chown -R <username>: app/
After that, you can create the systemd configuration:
vi systemd/inverter-charge-controller.service
sudo ln -s <path to repository>/systemd/inverter-charge-controller.service /etc/systemd/system
sudo systemctl daemon-reload
Once done, you can control the program like any other systemd service:
- Status:
sudo systemctl status inverter-charge-controller.service
- Starting:
sudo systemctl start inverter-charge-controller.service
- Stopping:
sudo systemctl stop inverter-charge-controller.service
- Restarting:
sudo systemctl restart inverter-charge-controller.service
- Enabling to run at boot:
sudo systemctl enable inverter-charge-controller.service
You can use the inverter script to control the inverter manually over the command line. It supports getting the current state of charge and operation mode and setting the operation mode.
The logs of the application are stored in <path to repository>/logs/
. They are rolled over once a logfile reaches 1 MB
in size. The current log and a maximum of 7
rolled over logfiles are saved.
See also the environment variables DIRECTORY_OF_LOGS
and LOGLEVEL
.
If you pass in --solar-forecast
as an argument to main.py
the programm just logs the expected solar forecast of the day.
This can also be used to log the solar prediction after the sun has set to see how far off the solar prediction was and get a sense of how good the predication was (→ not as a forecast but as a review). To correctly display the log message use --solar-review
in this case.
You can monitor how far the prediction of the solar forecast was off and how much power was bought with the script solar_forecast_logger.sh.
It saves the following data:
<directory> of logs>/power_buy.log
:<timestamp of start of charging>\t<timestamp of end of charging>\t<power bought in Wh>
<directory> of logs>/solar_forecast_difference.log
:<date>\t<prediction at start of day in Wh>\t<prediction at end of day in Wh>