Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

The CPD1802 disassembler wrongly sees 0x7C, 0x7D and 0x7F as one byte opcodes (v1.1.8) #13

Open
gulrak opened this issue Jan 3, 2024 · 0 comments
Assignees
Labels
available on main Feature or fix is merged into main bug Something isn't working

Comments

@gulrak
Copy link
Owner

gulrak commented Jan 3, 2024

The opcode disassembler of the CDP1802 omits the argument bytes of 0x7C (ADCI #<imm>), 0x7D (SDBI #<imm>) and 0x7F (SMBI #`), showing them as single byte opcodes instead of two byte.

@gulrak gulrak added the bug Something isn't working label Jan 3, 2024
@gulrak gulrak self-assigned this Jan 3, 2024
@gulrak gulrak added the available on main Feature or fix is merged into main label Jan 9, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment