Loss of Sync mid disc causing 1 second skip in RF #388
Comments
Various errors distributed across the disc that are probably all related due to incorrect levels in mastering. Happy to supply samples if needed It usually skips 2 seconds before locking on again but sometimes has a single frame whet the lock is good between the two second jumps. file frame 4133 CLV timecode 2:07.02 frame 3812 |
It might be better @happycube to use a 1 second skip when starting a capture; but reduce this to a much smaller skip in the event of mid-decode sync loss? |
That sounds good to me... I'll probably change it to a 1-2 field skip once
it's decoded a few frames.
…On Tue, Dec 31, 2019 at 11:01 PM Simon Inns ***@***.***> wrote:
It might be better @happycube <https://github.com/happycube> to use a 1
second skip when starting a capture; but reduce this to a much smaller skip
in the event of mid-decode sync loss?
—
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub
<#388?email_source=notifications&email_token=AAAXFCBUDOL4IMM3JSR36Y3Q3Q5WJA5CNFSM4KA75JCKYY3PNVWWK3TUL52HS4DFVREXG43VMVBW63LNMVXHJKTDN5WW2ZLOORPWSZGOEH47FQY#issuecomment-570028739>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AAAXFCGA3MAYFT7JAARW44TQ3Q5WJANCNFSM4KA75JCA>
.
|
Seems related to #264 |
From the middle of a decode:
file frame 19399 CLV timecode 10:36.13 frame 19093
file frame 19400 CLV timecode 10:36.14 frame 19094
file frame 19401 CLV timecode 10:36.15 frame 19095
file frame 19402 CLV timecode 10:36.16 frame 19096
file frame 19403 CLV timecode 10:36.17 frame 19097
file frame 19404 CLV timecode 10:36.18 frame 19098
file frame 19405 CLV timecode 10:36.19 frame 19099
ERROR:root:Unable to find any sync pulses, jumping one second
ERROR:root:Unable to find any sync pulses, jumping one second
file frame 19466 CLV timecode 10:38.20 frame 19160
file frame 19467 CLV timecode 10:38.21 frame 19161
file frame 19468 CLV timecode 10:38.22 frame 19162
file frame 19469 CLV timecode 10:38.23 frame 19163
file frame 19470 CLV timecode 10:38.24 frame 19164
file frame 19471 CLV timecode 10:38.25 frame 19165
From Happycube on IRC:
looks like the carrier's dipped low, this disk needs AGC - Because Technidisc(tm)
sample supplied of 100 frames
The text was updated successfully, but these errors were encountered: