Capture Quality Index - treatment of SNR values #433

Closed
simoninns opened this issue Jan 25, 2020 · 1 comment
Closed

Capture Quality Index - treatment of SNR values #433

simoninns opened this issue Jan 25, 2020 · 1 comment
Labels
enhancement ld-decode-tools An issue only affecting the ld-decode-tools

Comments

@simoninns
Copy link
Collaborator

The CQI value calculated by ld-analyse and ld-discmap treats the SNR as a linear value when weighting the results. SNR is non-linear and should be converted from logarithmic to linear in the calculation to make the results 'more' correct.

@simoninns simoninns added enhancement ld-decode-tools An issue only affecting the ld-decode-tools labels Jan 25, 2020
simoninns pushed a commit that referenced this issue Jan 25, 2020
simoninns pushed a commit that referenced this issue Jan 25, 2020
@simoninns
Copy link
Collaborator Author

Fixed