Feature: DPL: explicit support for solar powered inverters
Browse files Browse the repository at this point in the history
by default and until this change, we assumed that the inverter
controlled by the DPL is powered by a battery. not all users have a
battery in their system. they still use the DPL to achieve net-zero
export. those users can now tell the DPL that their inverter is powered
by solar modules rather than a battery and the DPL will behave
accordingly.
  • Loading branch information
schlimmchen committed Mar 9, 2024
1 parent be15050 commit 91f8f61
Show file tree
Hide file tree
Showing 2 changed files with 73 additions and 73 deletions.
7 changes: 5 additions & 2 deletions include/PowerLimiter.h
Original file line number Diff line number Diff line change
Expand Up @@ -40,8 +40,11 @@ class PowerLimiterClass {
InverterPowerCmdPending,
InverterDevInfoPending,
InverterStatsPending,
CalculatedLimitBelowMinLimit,
UnconditionalSolarPassthrough,
NoVeDirect,
NoEnergy,
HuaweiPsu,
Settling,
Stable,
};
Expand Down Expand Up @@ -91,10 +94,10 @@ class PowerLimiterClass {
int32_t inverterPowerDcToAc(std::shared_ptr<InverterAbstract> inverter, int32_t dcPower);
void unconditionalSolarPassthrough(std::shared_ptr<InverterAbstract> inverter);
bool canUseDirectSolarPower();
int32_t calcPowerLimit(std::shared_ptr<InverterAbstract> inverter, bool solarPowerEnabled, bool batteryDischargeEnabled);
bool calcPowerLimit(std::shared_ptr<InverterAbstract> inverter, int32_t solarPower, bool batteryPower);
bool updateInverter();
bool setNewPowerLimit(std::shared_ptr<InverterAbstract> inverter, int32_t newPowerLimit);
int32_t getSolarChargePower();
int32_t getSolarPower();
float getLoadCorrectedVoltage();
bool testThreshold(float socThreshold, float voltThreshold,
std::function<bool(float, float)> compare);
Expand Down
139 changes: 68 additions & 71 deletions src/PowerLimiter.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -31,7 +31,7 @@ frozen::string const& PowerLimiterClass::getStatusText(PowerLimiterClass::Status
{
static const frozen::string missing = "programmer error: missing status text";

static const frozen::map<Status, frozen::string, 18> texts = {
static const frozen::map<Status, frozen::string, 21> texts = {
{ Status::Initializing, "initializing (should not see me)" },
{ Status::DisabledByConfig, "disabled by configuration" },
{ Status::DisabledByMqtt, "disabled by MQTT" },
Expand All @@ -47,8 +47,11 @@ frozen::string const& PowerLimiterClass::getStatusText(PowerLimiterClass::Status
{ Status::InverterPowerCmdPending, "waiting for a start/stop/restart command to complete" },
{ Status::InverterDevInfoPending, "waiting for inverter device information to be available" },
{ Status::InverterStatsPending, "waiting for sufficiently recent inverter data" },
{ Status::CalculatedLimitBelowMinLimit, "calculated limit is less than lower power limit" },
{ Status::UnconditionalSolarPassthrough, "unconditionally passing through all solar power (MQTT override)" },
{ Status::NoVeDirect, "VE.Direct disabled, connection broken, or data outdated" },
{ Status::NoEnergy, "no energy source available to power the inverter from" },
{ Status::HuaweiPsu, "DPL stands by while Huawei PSU is enabled/charging" },
{ Status::Stable, "the system is stable, the last power limit is still valid" },
};

Expand Down Expand Up @@ -225,6 +228,8 @@ void PowerLimiterClass::loop()
}

auto getBatteryPower = [this,&config]() -> bool {
if (config.PowerLimiter.IsInverterSolarPowered) { return false; }

if (isStopThresholdReached()) { return false; }

if (isStartThresholdReached()) { return true; }
Expand All @@ -237,7 +242,7 @@ void PowerLimiterClass::loop()
// power do not cause the start of a discharge cycle during the day.
if (config.PowerLimiter.SolarPassThroughEnabled &&
config.PowerLimiter.BatteryDrainStategy == EMPTY_AT_NIGHT) {
return !canUseDirectSolarPower();
return getSolarPower() == 0;
}

// we are between start and stop threshold and keep the state that was
Expand All @@ -251,7 +256,9 @@ void PowerLimiterClass::loop()
MessageOutput.printf("[DPL::loop] PowerMeter: %d W, target consumption: %d W, solar power: %d W\r\n",
static_cast<int32_t>(round(PowerMeter.getPowerTotal())),
config.PowerLimiter.TargetPowerConsumption,
getSolarChargePower());
getSolarPower());

if (config.PowerLimiter.IsInverterSolarPowered) { return; }

MessageOutput.printf("[DPL::loop] battery interface %s, SoC: %d %%, StartTH: %d %%, StopTH: %d %%, SoC age: %d s, ignore: %s\r\n",
(config.Battery.Enabled?"enabled":"disabled"),
Expand Down Expand Up @@ -281,8 +288,7 @@ void PowerLimiterClass::loop()
if (_verboseLogging) { logging(); }

// Calculate and set Power Limit (NOTE: might reset _inverter to nullptr!)
int32_t newPowerLimit = calcPowerLimit(_inverter, canUseDirectSolarPower(), _batteryDischargeEnabled);
bool limitUpdated = setNewPowerLimit(_inverter, newPowerLimit);
bool limitUpdated = calcPowerLimit(_inverter, getSolarPower(), _batteryDischargeEnabled);

_lastCalculation = millis();

Expand Down Expand Up @@ -396,46 +402,39 @@ uint8_t PowerLimiterClass::getPowerLimiterState() {
return PL_UI_STATE_INACTIVE;
}

bool PowerLimiterClass::canUseDirectSolarPower()
// Logic table
// | Case # | batteryPower | solarPower > 0 | useFullSolarPassthrough | Result |
// | 1 | false | false | doesn't matter | PL = 0 |
// | 2 | false | true | doesn't matter | PL = Victron Power |
// | 3 | true | doesn't matter | false | PL = PowerMeter value (Battery can supply unlimited energy) |
// | 4 | true | false | true | PL = PowerMeter value |
// | 5 | true | true | true | PL = max(PowerMeter value, Victron Power) |

bool PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inverter, int32_t solarPowerDC, bool batteryPower)
{
CONFIG_T& config = Configuration.get();

if (!config.PowerLimiter.SolarPassThroughEnabled
|| isBelowStopThreshold()
|| !VictronMppt.isDataValid()) {
return false;
if (solarPowerDC == 0 && !batteryPower) {
return shutdown(Status::NoEnergy);
}

return VictronMppt.getPowerOutputWatts() >= 20; // enough power?
}

// We check if the PSU is on and disable the Power Limiter in this case.
// The PSU should reduce power or shut down first before the Power Limiter
// kicks in. The only case where this is not desired is if the battery is
// over the Full Solar Passthrough Threshold. In this case the Power
// Limiter should run and the PSU will shut down as a consequence.
if (!useFullSolarPassthrough() && HuaweiCan.getAutoPowerStatus()) {
return shutdown(Status::HuaweiPsu);
}

// Logic table
// | Case # | batteryDischargeEnabled | solarPowerEnabled | useFullSolarPassthrough | Result |
// | 1 | false | false | doesn't matter | PL = 0 |
// | 2 | false | true | doesn't matter | PL = Victron Power |
// | 3 | true | doesn't matter | false | PL = PowerMeter value (Battery can supply unlimited energy) |
// | 4 | true | false | true | PL = PowerMeter value |
// | 5 | true | true | true | PL = max(PowerMeter value, Victron Power) |

int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inverter, bool solarPowerEnabled, bool batteryDischargeEnabled)
{
CONFIG_T& config = Configuration.get();

int32_t acPower = 0;
int32_t newPowerLimit = round(PowerMeter.getPowerTotal());

if (!solarPowerEnabled && !batteryDischargeEnabled) {
// Case 1 - No energy sources available
return 0;
}
auto const& config = Configuration.get();

if (config.PowerLimiter.IsInverterBehindPowerMeter) {
// If the inverter the behind the power meter (part of measurement),
// the produced power of this inverter has also to be taken into account.
// We don't use FLD_PAC from the statistics, because that
// data might be too old and unreliable.
acPower = static_cast<int>(inverter->Statistics()->getChannelFieldValue(TYPE_AC, CH0, FLD_PAC));
auto acPower = inverter->Statistics()->getChannelFieldValue(TYPE_AC, CH0, FLD_PAC);
newPowerLimit += acPower;
}

Expand All @@ -444,38 +443,25 @@ int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inve
// Case 3
newPowerLimit -= config.PowerLimiter.TargetPowerConsumption;

// At this point we've calculated the required energy to compensate for household consumption.
// If the battery is enabled this can always be supplied since we assume that the battery can supply unlimited power
// The next step is to determine if the Solar power as provided by the Victron charger
// actually constrains or dictates another inverter power value
int32_t adjustedVictronChargePower = inverterPowerDcToAc(inverter, getSolarChargePower());
int32_t solarPowerAC = inverterPowerDcToAc(inverter, solarPowerDC);

// Battery can be discharged and we should output max (Victron solar power || power meter value)
if(batteryDischargeEnabled && useFullSolarPassthrough()) {
// Case 5
newPowerLimit = newPowerLimit > adjustedVictronChargePower ? newPowerLimit : adjustedVictronChargePower;
} else {
// We check if the PSU is on and disable the Power Limiter in this case.
// The PSU should reduce power or shut down first before the Power Limiter kicks in
// The only case where this is not desired is if the battery is over the Full Solar Passthrough Threshold
// In this case the Power Limiter should start. The PSU will shutdown when the Power Limiter is active
if (HuaweiCan.getAutoPowerStatus()) {
return 0;
}
}

// We should use Victron solar power only (corrected by efficiency factor)
if (solarPowerEnabled && !batteryDischargeEnabled) {
// Case 2 - Limit power to solar power only
if (!batteryPower) {
// do not drain the battery. use as much power as needed to match the
// household consumption, but not more than the available solar power.
if (_verboseLogging) {
MessageOutput.printf("[DPL::loop] Consuming Solar Power Only -> adjustedVictronChargePower: %d W, newPowerLimit: %d W\r\n",
adjustedVictronChargePower, newPowerLimit);
MessageOutput.printf("[DPL::loop] Consuming Solar Power Only -> solarPowerAC: %d W, newPowerLimit: %d W\r\n",
solarPowerAC, newPowerLimit);
}

newPowerLimit = std::min(newPowerLimit, adjustedVictronChargePower);
return setNewPowerLimit(inverter, std::min(newPowerLimit, solarPowerAC));
}

return newPowerLimit;
// convert all solar power if full solar-passthrough is active
if (useFullSolarPassthrough()) {
return setNewPowerLimit(inverter, std::max(newPowerLimit, solarPowerAC));
}

return setNewPowerLimit(inverter, newPowerLimit);
}

/**
Expand Down Expand Up @@ -665,13 +651,10 @@ static int32_t scalePowerLimit(std::shared_ptr<InverterAbstract> inverter, int32
*/
bool PowerLimiterClass::setNewPowerLimit(std::shared_ptr<InverterAbstract> inverter, int32_t newPowerLimit)
{
CONFIG_T& config = Configuration.get();
auto const& config = Configuration.get();

// Stop the inverter if limit is below threshold.
if (newPowerLimit < config.PowerLimiter.LowerPowerLimit) {
// the status must not change outside of loop(). this condition is
// communicated through log messages already.
return shutdown();
return shutdown(Status::CalculatedLimitBelowMinLimit);
}

// enforce configured upper power limit
Expand Down Expand Up @@ -705,13 +688,26 @@ bool PowerLimiterClass::setNewPowerLimit(std::shared_ptr<InverterAbstract> inver
return updateInverter();
}

int32_t PowerLimiterClass::getSolarChargePower()
int32_t PowerLimiterClass::getSolarPower()
{
if (!canUseDirectSolarPower()) {
auto const& config = Configuration.get();

if (config.PowerLimiter.IsInverterSolarPowered) {
// the returned value is arbitrary, as long as it's
// greater than the inverters max DC power consumption.
return 10 * 1000;
}

if (!config.PowerLimiter.SolarPassThroughEnabled
|| isBelowStopThreshold()
|| !VictronMppt.isDataValid()) {
return 0;
}

return VictronMppt.getPowerOutputWatts();
auto solarPower = VictronMppt.getPowerOutputWatts();
if (solarPower < 20) { return 0; } // too little to work with

return solarPower;
}

float PowerLimiterClass::getLoadCorrectedVoltage()
Expand Down Expand Up @@ -830,12 +826,13 @@ void PowerLimiterClass::calcNextInverterRestart()

bool PowerLimiterClass::useFullSolarPassthrough()
{
CONFIG_T& config = Configuration.get();
auto const& config = Configuration.get();

// solar passthrough only applies to setups with battery-powered inverters
if (config.PowerLimiter.IsInverterSolarPowered) { return false; }

// We only do full solar PT if general solar PT is enabled
if(!config.PowerLimiter.SolarPassThroughEnabled) {
return false;
}
if(!config.PowerLimiter.SolarPassThroughEnabled) { return false; }

if (testThreshold(config.PowerLimiter.FullSolarPassThroughSoc,
config.PowerLimiter.FullSolarPassThroughStartVoltage,
Expand Down

0 comments on commit 91f8f61

Please sign in to comment.