-
Notifications
You must be signed in to change notification settings - Fork 0
Maxim DS1337 Real Time Clock code for PIC microcontrollers and other C compilers
License
ibexuk/C_RTC_Maxim_DS1337
Folders and files
Name | Name | Last commit message | Last commit date | |
---|---|---|---|---|
Repository files navigation
###################################################################### ##### Open sourced by IBEX, an electronic product design company ##### ##### based in South East England. http://www.ibexuk.com ##### ###################################################################### The Dallas Maxim DS1337 is a I2C serial bus real time clock. It provides low power time keeping for embedded designs with two alarm output pins. This driver provides the following functions: SET REAL TIME CLOCK TIME BYTE rtc_set_time (BYTE alarms_enabled, BYTE hours, BYTE minutes, BYTE seconds, BYTE day, BYTE date, BYTE month, BYTE year) The fields are converted from binary to BCD before being sent to the RTC alarms_enabled 0 = alarms disabled, bit0 = alarm 1 enable, bit1 = alarm 2 enable, bit2 = alarms trigger INTA & INTB (0=both trigger INTA) hours 0 – 23 minutes 0 – 59 seconds 0 – 59 day 1 – 7 date 1 – 31 month 1 – 12 year 0 – 99 GET REAL TIME CLOCK TIME BYTE rtc_get_time (BYTE *hours, BYTE *minutes, BYTE *seconds, BYTE *day, BYTE *date, BYTE *month, BYTE *year) All fields are converted to binary values hours 0 – 23 minutes 0 – 59 seconds 0 – 59 day 1 – 7 date 1 – 31 month 1 – 12 year 0 – 99 SET REAL TIME CLOCK ALARM BYTE rtc_set_alarm (BYTE alarm_id, BYTE alarms_enabled, BYTE hours, BYTE minutes, BYTE seconds, BYTE date_day) The fields are converted from binary to BCD before being sent to the RTC alarm_id 1 – 2 alarms_enabled 0 = alarms disabled, bit0 = alarm 1 enable, bit1 = alarm 2 enable, bit2 = alarms trigger INTA & INTB (0=both trigger INTA) hours 0 – 23 minutes 0 – 59 seconds 0 – 59 (not available for alarm 2) date_day 1 – 31 (dates) or 101 – 107 (days) Set any value to 0xff to be ignored in the alarm comparison Note: After an alarm is activated the INT pin will remain driven low until rtc_clear_alarms() is called CLEAR REAL TIME CLOCK ALARMS BYTE rtc_clear_alarms (void) When an enabled alarm trips the alarm flags must be cleared using this function to reset the INT pin(s). Please view the sample source code files for full information regarding the driver.
About
Maxim DS1337 Real Time Clock code for PIC microcontrollers and other C compilers
Resources
License
Stars
Watchers
Forks
Releases
No releases published
Packages 0
No packages published