Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Cannot convert undefined or null to object #374

Closed
geigl opened this issue Oct 5, 2023 · 13 comments
Closed

Cannot convert undefined or null to object #374

geigl opened this issue Oct 5, 2023 · 13 comments

Comments

@geigl
Copy link

geigl commented Oct 5, 2023

TypeError: Cannot convert undefined or null to object at hasOwnProperty () at fillDataObject (/opt/iobroker/node_modules/iobroker.fronius/main.js:1173:41) at Timeout._onTimeout (/opt/iobroker/node_modules/iobroker.fronius/main.js:1231:13) at listOnTimeout (node:internal/timers:571:11) at process.processTimers (node:internal/timers:512:7)

error | uncaught exception: Cannot convert undefined or null to object

Fronius Symo Hybrid
kein Fehler mit Fronius Gen24

Adapterversion 2.0.2
JS-Controller 5.0.12
Node 18.8
NPM 9.8.1

@nkleber78
Copy link
Collaborator

@geigl kannst du hier etwas mehr info liefern? Wann tritt das auf (regelmäßig oder nur sporadisch z.b. beim abschalten des Inverters ...)

@geigl
Copy link
Author

geigl commented Oct 11, 2023

Seit die Protokollierung auf Debug steht ist kein Fehler mehr aufgetreten.

@geigl
Copy link
Author

geigl commented Dec 14, 2023

`

host.raspberrypi 2024-01-16 19:43:28.316 error instance system.adapter.fronius.0 terminated with code 6 (UNCAUGHT_EXCEPTION)
fronius.0 2024-01-16 19:43:27.210 error Cannot convert undefined or null to object
fronius.0 2024-01-16 19:43:27.209 error TypeError: Cannot convert undefined or null to object at hasOwnProperty () at fillDataObject (/opt/iobroker/node_modules/iobroker.fronius/main.js:1173:41) at Timeout._onTimeout (/opt/iobroker/node_modules/iobroker.fronius/main.js:1231:13) at listOnTimeout (node:internal/timers:571:11) at process.processTimers (node:internal/timers:512:7)
fronius.0 2024-01-16 19:43:27.209 error uncaught exception: Cannot convert undefined or null to object
fronius.0 2024-01-16 19:43:27.207 error Cannot convert undefined or null to object
fronius.0 2024-01-16 19:43:27.206 error TypeError: Cannot convert undefined or null to object at hasOwnProperty () at fillDataObject (/opt/iobroker/node_modules/iobroker.fronius/main.js:1173:41) at Timeout._onTimeout (/opt/iobroker/node_modules/iobroker.fronius/main.js:1231:13) at listOnTimeout (node:internal/timers:571:11) at process.processTimers (node:internal/timers:512:7)
fronius.0 2024-01-16 19:43:27.200 error uncaught exception: Cannot convert undefined or null to object
`

@geigl
Copy link
Author

geigl commented Mar 15, 2024

Der Fehler kommt zu unterschiedlichen Zeitpunkten, ob der Inverter dabei einen Neustart macht kann ich nicht beantworten, aktiv von mit wird keiner ausgelöst. Der Fehler tritt erst seit der Anhebung des Adapters auf Verion 2.x.x auf.
Hier ein Auszug aus dem debug-log.
bei 00:53:2 tritt der Fehler auf, ich habe eine Abfrage vorher und einige danach mit angehängt:

2024-03-13 00:53:11.485 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=MinMaxInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"MinMaxInverterData","DeviceClass":"Inverter","Scope":"Device"},"Status":{"Code":6,"Reason":"CGI-Args: Invalid parameter 'MinMaxInverterData' for attribute 'DataCollection' (use 'CumulationInverterData', 'CommonInverterData' or '3PInverterData' )","UserMessage":""},"Timestamp":"2024-03-13T00:53:11+01:00"}} 2024-03-13 00:53:11.533 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetMeterRealtimeData.cgi?Scope=Device&DeviceId=1: {"Body":{"Data":{"Current_AC_Phase_1":0.075,"Current_AC_Phase_2":0,"Current_AC_Phase_3":0,"Current_AC_Sum":0.075,"Details":{"Manufacturer":"Fronius","Model":"Smart Meter TS 65A-3","Serial":"2131035562"},"Enable":1,"EnergyReactive_VArAC_Sum_Consumed":70839,"EnergyReactive_VArAC_Sum_Produced":41452,"EnergyReal_WAC_Minus_Absolute":8636504,"EnergyReal_WAC_Plus_Absolute":212093,"EnergyReal_WAC_Sum_Consumed":212093,"EnergyReal_WAC_Sum_Produced":8636504,"Frequency_Phase_Average":50,"Meter_Location_Current":0,"PowerApparent_S_Phase_1":9.1,"PowerApparent_S_Phase_2":0,"PowerApparent_S_Phase_3":0,"PowerApparent_S_Sum":9.1,"PowerFactor_Phase_1":0.966,"PowerFactor_Phase_2":0,"PowerFactor_Phase_3":0,"PowerFactor_Sum":0.851,"PowerReactive_Q_Phase_1":-2.3,"PowerReactive_Q_Phase_2":0,"PowerReactive_Q_Phase_3":0,"PowerReactive_Q_Sum":-2.3,"PowerReal_P_Phase_1":8.8,"PowerReal_P_Phase_2":0,"PowerReal_P_Phase_3":0,"PowerReal_P_Sum":8.8,"TimeStamp":1710287591,"Visible":1,"Voltage_AC_PhaseToPhase_12":400.9,"Voltage_AC_PhaseToPhase_23":403.7,"Voltage_AC_PhaseToPhase_31":400.5,"Voltage_AC_Phase_1":232,"Voltage_AC_Phase_2":231,"Voltage_AC_Phase_3":232.9}},"Head":{"RequestArguments":{"DeviceClass":"Meter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:11+01:00"}} 2024-03-13 00:53:11.689 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetStorageRealtimeData.cgi?Scope=Device&DeviceId=1: {"Body":{"Data":{"Controller":{"Capacity_Maximum":9600,"Current_DC":-0.01,"DesignedCapacity":9600,"Details":{"Manufacturer":"Fronius","Model":"Fronius Solar Battery","Serial":"28340625"},"Enable":1,"TimeStamp":1710287587},"Modules":[{"Capacity_Maximum":1200,"Current_DC":0,"CycleCount_BatteryCell":1224,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013005593 "},"Enable":1,"StateOfCharge_Relative":10,"Status_BatteryCell":53,"Temperature_Cell":25.850000000000023,"Temperature_Cell_Maximum":26.05000000000001,"Temperature_Cell_Minimum":25.450000000000045,"TimeStamp":1710287570,"Voltage_DC":50.69,"Voltage_DC_Maximum_Cell":3.172,"Voltage_DC_Minimum_Cell":3.165},{"Capacity_Maximum":1200,"Current_DC":-0.03,"CycleCount_BatteryCell":1222,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013800172 "},"Enable":1,"StateOfCharge_Relative":5,"Status_BatteryCell":83,"Temperature_Cell":25.850000000000023,"Temperature_Cell_Maximum":26.350000000000023,"Temperature_Cell_Minimum":25.650000000000034,"TimeStamp":1710287570,"Voltage_DC":49.758,"Voltage_DC_Maximum_Cell":3.118,"Voltage_DC_Minimum_Cell":3.102},{"Capacity_Maximum":1200,"Current_DC":-0.02,"CycleCount_BatteryCell":1215,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013005527 "},"Enable":1,"StateOfCharge_Relative":7,"Status_BatteryCell":83,"Temperature_Cell":25.55000000000001,"Temperature_Cell_Maximum":25.950000000000045,"Temperature_Cell_Minimum":25.150000000000034,"TimeStamp":1710287570,"Voltage_DC":49.92,"Voltage_DC_Maximum_Cell":3.128,"Voltage_DC_Minimum_Cell":3.112},{"Capacity_Maximum":1200,"Current_DC":-0.01,"CycleCount_BatteryCell":1203,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013005682 "},"Enable":1,"StateOfCharge_Relative":8,"Status_BatteryCell":83,"Temperature_Cell":25.450000000000045,"Temperature_Cell_Maximum":26.05000000000001,"Temperature_Cell_Minimum":25.25,"TimeStamp":1710287570,"Voltage_DC":50.15,"Voltage_DC_Maximum_Cell":3.14,"Voltage_DC_Minimum_Cell":3.127},{"Capacity_Maximum":1200,"Current_DC":-0.02,"CycleCount_BatteryCell":1112,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013020857 "},"Enable":1,"StateOfCharge_Relative":14,"Status_BatteryCell":83,"Temperature_Cell":24.850000000000023,"Temperature_Cell_Maximum":25.25,"Temperature_Cell_Minimum":24.350000000000023,"TimeStamp":1710287570,"Voltage_DC":50.858,"Voltage_DC_Maximum_Cell":3.183,"Voltage_DC_Minimum_Cell":3.177},{"Capacity_Maximum":1200,"Current_DC":-0.02,"CycleCount_BatteryCell":1115,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013020849 "},"Enable":1,"StateOfCharge_Relative":14,"Status_BatteryCell":83,"Temperature_Cell":24.350000000000023,"Temperature_Cell_Maximum":24.75,"Temperature_Cell_Minimum":23.650000000000034,"TimeStamp":1710287570,"Voltage_DC":50.881,"Voltage_DC_Maximum_Cell":3.184,"Voltage_DC_Minimum_Cell":3.176},{"Capacity_Maximum":1200,"Current_DC":-0.02,"CycleCount_BatteryCell":1114,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013020862 "},"Enable":1,"StateOfCharge_Relative":14,"Status_BatteryCell":83,"Temperature_Cell":23.55000000000001,"Temperature_Cell_Maximum":24.150000000000034,"Temperature_Cell_Minimum":23.150000000000034,"TimeStamp":1710287570,"Voltage_DC":50.935,"Voltage_DC_Maximum_Cell":3.187,"Voltage_DC_Minimum_Cell":3.18},{"Capacity_Maximum":1200,"Current_DC":-0.02,"CycleCount_BatteryCell":1111,"DesignedCapacity":1200,"Details":{"Manufacturer":"Sony","Model":"unknown","Serial":"S013020819 "},"Enable":1,"StateOfCharge_Relative":16,"Status_BatteryCell":83,"Temperature_Cell":22.850000000000023,"Temperature_Cell_Maximum":23.25,"Temperature_Cell_Minimum":22.350000000000023,"TimeStamp":1710287570,"Voltage_DC":50.958,"Voltage_DC_Maximum_Cell":3.188,"Voltage_DC_Minimum_Cell":3.183}]}},"Head":{"RequestArguments":{"DeviceClass":"Storage","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:11+01:00"}} 2024-03-13 00:53:11.724 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetPowerFlowRealtimeData.fcgi: {"Body":{"Data":{"Inverters":{"1":{"Battery_Mode":"suspended","DT":99,"E_Day":1309.5999755859375,"E_Total":21246630,"E_Year":262666.5,"P":0,"SOC":5}},"Site":{"BatteryStandby":true,"E_Day":1309.6000000000001,"E_Total":21246629.8,"E_Year":262666.5,"Meter_Location":"grid","Mode":"bidirectional","P_Akku":null,"P_Grid":9.5,"P_Load":-9.5,"P_PV":null,"rel_Autonomy":0,"rel_SelfConsumption":null},"Version":"12"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:11+01:00"}} 2024-03-13 00:53:11.728 - �[34mdebug�[39m: fronius.0 (198405) API Objekt P_Akku is null, object site.P_Akku will be set to 0! 2024-03-13 00:53:11.728 - �[34mdebug�[39m: fronius.0 (198405) API Objekt P_PV is null, object site.P_PV will be set to 0! 2024-03-13 00:53:11.728 - �[34mdebug�[39m: fronius.0 (198405) API Objekt rel_SelfConsumption is null, object site.rel_SelfConsumption will be set to 0! 2024-03-13 00:53:11.884 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetInverterInfo.cgi: {"Body":{"Data":{"1":{"CustomName":"&#68;&#114;&#46;&#32;&#84;&#104;&#111;&#109;&#97;&#115;&#32;&#71;&#101;&#105;&#103;&#108;","DT":99,"ErrorCode":0,"PVPower":5660,"Show":1,"StatusCode":3,"UniqueID":"1123205"}}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:11+01:00"}} 2024-03-13 00:53:11.891 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetOhmPilotRealtimeData.cgi?Scope=System: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DeviceClass":"OhmPilot","Scope":"System"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:11+01:00"}} 2024-03-13 00:53:11.902 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=3PInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"3PInverterData","DeviceClass":"Inverter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:11+01:00"}} 2024-03-13 00:53:21.529 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=CommonInverterData: {"Body":{"Data":{"DAY_ENERGY":{"Unit":"Wh","Value":1309},"DeviceStatus":{"ErrorCode":0,"LEDColor":0,"LEDState":0,"MgmtTimerRemainingTime":-1,"StateToReset":false,"StatusCode":3},"IDC":{"Unit":"A","Value":0},"TOTAL_ENERGY":{"Unit":"Wh","Value":21246629},"UDC":{"Unit":"V","Value":102.4},"YEAR_ENERGY":{"Unit":"Wh","Value":262666}}},"Head":{"RequestArguments":{"DataCollection":"CommonInverterData","DeviceClass":"Inverter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:21.536 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=MinMaxInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"MinMaxInverterData","DeviceClass":"Inverter","Scope":"Device"},"Status":{"Code":6,"Reason":"CGI-Args: Invalid parameter 'MinMaxInverterData' for attribute 'DataCollection' (use 'CumulationInverterData', 'CommonInverterData' or '3PInverterData' )","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:21.669 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetMeterRealtimeData.cgi?Scope=Device&DeviceId=1: {"Body":{"Data":{"Current_AC_Phase_1":0.077,"Current_AC_Phase_2":0,"Current_AC_Phase_3":0,"Current_AC_Sum":0.077,"Details":{"Manufacturer":"Fronius","Model":"Smart Meter TS 65A-3","Serial":"2131035562"},"Enable":1,"EnergyReactive_VArAC_Sum_Consumed":70839,"EnergyReactive_VArAC_Sum_Produced":41452,"EnergyReal_WAC_Minus_Absolute":8636504,"EnergyReal_WAC_Plus_Absolute":212094,"EnergyReal_WAC_Sum_Consumed":212094,"EnergyReal_WAC_Sum_Produced":8636504,"Frequency_Phase_Average":50,"Meter_Location_Current":0,"PowerApparent_S_Phase_1":9.3,"PowerApparent_S_Phase_2":0,"PowerApparent_S_Phase_3":0,"PowerApparent_S_Sum":9.3,"PowerFactor_Phase_1":0.969,"PowerFactor_Phase_2":0,"PowerFactor_Phase_3":0,"PowerFactor_Sum":0.872,"PowerReactive_Q_Phase_1":-2.3,"PowerReactive_Q_Phase_2":0,"PowerReactive_Q_Phase_3":0,"PowerReactive_Q_Sum":-2.3,"PowerReal_P_Phase_1":9.1,"PowerReal_P_Phase_2":0,"PowerReal_P_Phase_3":0,"PowerReal_P_Sum":9.1,"TimeStamp":1710287601,"Visible":1,"Voltage_AC_PhaseToPhase_12":401.3,"Voltage_AC_PhaseToPhase_23":404.1,"Voltage_AC_PhaseToPhase_31":400.9,"Voltage_AC_Phase_1":232.2,"Voltage_AC_Phase_2":231.2,"Voltage_AC_Phase_3":233.1}},"Head":{"RequestArguments":{"DeviceClass":"Meter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:21.705 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetStorageRealtimeData.cgi?Scope=Device&DeviceId=1: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DeviceClass":"Storage","DeviceId":"1","Scope":"Device"},"Status":{"Code":255,"Reason":"DeviceId '1' is not enabled","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:21.707 - �[31merror�[39m: fronius.0 (198405) uncaught exception: Cannot convert undefined or null to object 2024-03-13 00:53:21.709 - �[31merror�[39m: fronius.0 (198405) TypeError: Cannot convert undefined or null to object at hasOwnProperty (<anonymous>) at fillDataObject (/opt/iobroker/node_modules/iobroker.fronius/main.js:1173:41) at Timeout._onTimeout (/opt/iobroker/node_modules/iobroker.fronius/main.js:1231:13) at listOnTimeout (node:internal/timers:575:11) at process.processTimers (node:internal/timers:514:7) 2024-03-13 00:53:21.709 - �[31merror�[39m: fronius.0 (198405) Cannot convert undefined or null to object 2024-03-13 00:53:21.711 - �[31merror�[39m: fronius.0 (198405) uncaught exception: Cannot convert undefined or null to object 2024-03-13 00:53:21.711 - �[31merror�[39m: fronius.0 (198405) TypeError: Cannot convert undefined or null to object at hasOwnProperty (<anonymous>) at fillDataObject (/opt/iobroker/node_modules/iobroker.fronius/main.js:1173:41) at Timeout._onTimeout (/opt/iobroker/node_modules/iobroker.fronius/main.js:1231:13) at listOnTimeout (node:internal/timers:575:11) at process.processTimers (node:internal/timers:514:7) 2024-03-13 00:53:21.711 - �[31merror�[39m: fronius.0 (198405) Cannot convert undefined or null to object 2024-03-13 00:53:21.718 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetPowerFlowRealtimeData.fcgi: {"Body":{"Data":{"Inverters":{"1":{"Battery_Mode":"suspended","DT":99,"E_Day":1309.5999755859375,"E_Total":21246630,"E_Year":262666.5,"P":0,"SOC":5}},"Site":{"BatteryStandby":true,"E_Day":1309.6000000000001,"E_Total":21246629.8,"E_Year":262666.5,"Meter_Location":"grid","Mode":"bidirectional","P_Akku":null,"P_Grid":9.1,"P_Load":-9.1,"P_PV":null,"rel_Autonomy":0,"rel_SelfConsumption":null},"Version":"12"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:21.720 - �[34mdebug�[39m: fronius.0 (198405) API Objekt P_Akku is null, object site.P_Akku will be set to 0! 2024-03-13 00:53:21.720 - �[34mdebug�[39m: fronius.0 (198405) API Objekt P_PV is null, object site.P_PV will be set to 0! 2024-03-13 00:53:21.721 - �[34mdebug�[39m: fronius.0 (198405) API Objekt rel_SelfConsumption is null, object site.rel_SelfConsumption will be set to 0! 2024-03-13 00:53:21.766 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetInverterInfo.cgi: {"Body":{"Data":{"1":{"CustomName":"&#68;&#114;&#46;&#32;&#84;&#104;&#111;&#109;&#97;&#115;&#32;&#71;&#101;&#105;&#103;&#108;","DT":99,"ErrorCode":0,"PVPower":5660,"Show":1,"StatusCode":3,"UniqueID":"1123205"}}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:21.773 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetOhmPilotRealtimeData.cgi?Scope=System: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DeviceClass":"OhmPilot","Scope":"System"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:21.784 - �[34mdebug�[39m: fronius.0 (198405) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=3PInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"3PInverterData","DeviceClass":"Inverter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:21+01:00"}} 2024-03-13 00:53:22.233 - �[32minfo�[39m: fronius.0 (198405) terminating 2024-03-13 00:53:22.234 - �[33mwarn�[39m: fronius.0 (198405) Terminated (UNCAUGHT_EXCEPTION): Without reason 2024-03-13 00:53:22.832 - �[31merror�[39m: host.raspberrypi instance system.adapter.fronius.0 terminated with code 6 (UNCAUGHT_EXCEPTION) 2024-03-13 00:53:22.834 - �[32minfo�[39m: host.raspberrypi Restart adapter system.adapter.fronius.0 because enabled 2024-03-13 00:53:52.864 - �[32minfo�[39m: host.raspberrypi instance system.adapter.fronius.0 started with pid 200153 2024-03-13 00:53:54.193 - �[34mdebug�[39m: fronius.0 (200153) Redis Objects: Use Redis connection: 127.0.0.1:9001 2024-03-13 00:53:54.296 - �[34mdebug�[39m: fronius.0 (200153) Objects client ready ... initialize now 2024-03-13 00:53:54.355 - �[34mdebug�[39m: fronius.0 (200153) Objects create System PubSub Client 2024-03-13 00:53:54.357 - �[34mdebug�[39m: fronius.0 (200153) Objects create User PubSub Client 2024-03-13 00:53:54.417 - �[34mdebug�[39m: fronius.0 (200153) Objects client initialize lua scripts 2024-03-13 00:53:54.428 - �[34mdebug�[39m: fronius.0 (200153) Objects connected to redis: 127.0.0.1:9001 2024-03-13 00:53:54.462 - �[34mdebug�[39m: fronius.0 (200153) Redis States: Use Redis connection: 127.0.0.1:9000 2024-03-13 00:53:54.479 - �[34mdebug�[39m: fronius.0 (200153) States create System PubSub Client 2024-03-13 00:53:54.481 - �[34mdebug�[39m: fronius.0 (200153) States create User PubSub Client 2024-03-13 00:53:54.552 - �[34mdebug�[39m: fronius.0 (200153) States connected to redis: 127.0.0.1:9000 2024-03-13 00:53:54.735 - �[32minfo�[39m: fronius.0 (200153) starting. Version 2.0.2 in /opt/iobroker/node_modules/iobroker.fronius, node: v20.11.1, js-controller: 5.0.19 2024-03-13 00:53:54.899 - �[34mdebug�[39m: fronius.0 (200153) requestType https:// is not working! Now trying with http:// 2024-03-13 00:53:55.005 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetActiveDeviceInfo.cgi?DeviceClass=System: {"Body":{"Data":{"Inverter":{"1":{"DT":99}},"Meter":{"1":{"DT":-1,"Serial":"2131035562"}},"Ohmpilot":{},"SensorCard":{},"Storage":{},"StringControl":{}}},"Head":{"RequestArguments":{"DeviceClass":"System"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:54+01:00"}} 2024-03-13 00:53:55.006 - �[34mdebug�[39m: fronius.0 (200153) Current result of System deviceINFO: {"Inverter":{"1":{"DT":99}},"Meter":{"1":{"DT":-1,"Serial":"2131035562"}},"Ohmpilot":{},"SensorCard":{},"Storage":{},"StringControl":{}} 2024-03-13 00:53:55.008 - �[32minfo�[39m: fronius.0 (200153) The current system configuration is not up to date. Settings are updated and adapter restarted! 2024-03-13 00:53:55.037 - �[32minfo�[39m: host.raspberrypi stopInstance system.adapter.fronius.0 (force=false, process=true) 2024-03-13 00:53:55.041 - �[32minfo�[39m: fronius.0 (200153) Got terminate signal TERMINATE_YOURSELF 2024-03-13 00:53:55.096 - �[32minfo�[39m: host.raspberrypi stopInstance system.adapter.fronius.0 send kill signal 2024-03-13 00:53:55.157 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetLoggerInfo.cgi: {"Body":{"LoggerInfo":{"CO2Factor":0.5299999713897705,"CO2Unit":"kg","CashCurrency":"EUR","CashFactor":0.07999999821186066,"DefaultLanguage":"en","DeliveryFactor":0.3499999940395355,"HWVersion":"2.4D","PlatformID":"wilma","ProductID":"fronius-hybrid","SWVersion":"1.30.1-3","TimezoneLocation":"Vienna","TimezoneName":"CET","UTCOffset":3600,"UniqueID":"239.25145"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.241 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetLoggerInfo.cgi: {"Body":{"LoggerInfo":{"CO2Factor":0.5299999713897705,"CO2Unit":"kg","CashCurrency":"EUR","CashFactor":0.07999999821186066,"DefaultLanguage":"en","DeliveryFactor":0.3499999940395355,"HWVersion":"2.4D","PlatformID":"wilma","ProductID":"fronius-hybrid","SWVersion":"1.30.1-3","TimezoneLocation":"Vienna","TimezoneName":"CET","UTCOffset":3600,"UniqueID":"239.25145"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.251 - �[34mdebug�[39m: fronius.0 (200153) Object creation will be done for 1 times 2024-03-13 00:53:55.517 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=3PInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"3PInverterData","DeviceClass":"Inverter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.526 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetStorageRealtimeData.cgi?Scope=Device&DeviceId=1: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DeviceClass":"Storage","DeviceId":"1","Scope":"Device"},"Status":{"Code":255,"Reason":"DeviceId '1' is not enabled","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.543 - �[32minfo�[39m: fronius.0 (200153) terminating 2024-03-13 00:53:55.544 - �[32minfo�[39m: fronius.0 (200153) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason 2024-03-13 00:53:55.588 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetPowerFlowRealtimeData.fcgi: {"Body":{"Data":{"Inverters":{"1":{"Battery_Mode":"suspended","DT":99,"E_Day":1309.5999755859375,"E_Total":21246630,"E_Year":262666.5,"P":0,"SOC":5}},"Site":{"BatteryStandby":true,"E_Day":1309.6000000000001,"E_Total":21246629.8,"E_Year":262666.5,"Meter_Location":"grid","Mode":"bidirectional","P_Akku":null,"P_Grid":9.3,"P_Load":-9.3,"P_PV":null,"rel_Autonomy":0,"rel_SelfConsumption":null},"Version":"12"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.649 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetInverterInfo.cgi: {"Body":{"Data":{"1":{"CustomName":"&#68;&#114;&#46;&#32;&#84;&#104;&#111;&#109;&#97;&#115;&#32;&#71;&#101;&#105;&#103;&#108;","DT":99,"ErrorCode":0,"PVPower":5660,"Show":1,"StatusCode":2,"UniqueID":"1123205"}}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.665 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetOhmPilotRealtimeData.cgi?Scope=System: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DeviceClass":"OhmPilot","Scope":"System"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.704 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=CommonInverterData: {"Body":{"Data":{"DAY_ENERGY":{"Unit":"Wh","Value":1309},"DeviceStatus":{"ErrorCode":0,"LEDColor":0,"LEDState":0,"MgmtTimerRemainingTime":-1,"StateToReset":false,"StatusCode":2},"IDC":{"Unit":"A","Value":0},"TOTAL_ENERGY":{"Unit":"Wh","Value":21246629},"UDC":{"Unit":"V","Value":60.9},"YEAR_ENERGY":{"Unit":"Wh","Value":262666}}},"Head":{"RequestArguments":{"DataCollection":"CommonInverterData","DeviceClass":"Inverter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.739 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=MinMaxInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"MinMaxInverterData","DeviceClass":"Inverter","Scope":"Device"},"Status":{"Code":6,"Reason":"CGI-Args: Invalid parameter 'MinMaxInverterData' for attribute 'DataCollection' (use 'CumulationInverterData', 'CommonInverterData' or '3PInverterData' )","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:55.942 - �[34mdebug�[39m: fronius.0 (200153) Response to http://192.168.25.180/solar_api/v1/GetMeterRealtimeData.cgi?Scope=Device&DeviceId=1: {"Body":{"Data":{"Current_AC_Phase_1":0.078,"Current_AC_Phase_2":0,"Current_AC_Phase_3":0,"Current_AC_Sum":0.078,"Details":{"Manufacturer":"Fronius","Model":"Smart Meter TS 65A-3","Serial":"2131035562"},"Enable":1,"EnergyReactive_VArAC_Sum_Consumed":70839,"EnergyReactive_VArAC_Sum_Produced":41452,"EnergyReal_WAC_Minus_Absolute":8636504,"EnergyReal_WAC_Plus_Absolute":212094,"EnergyReal_WAC_Sum_Consumed":212094,"EnergyReal_WAC_Sum_Produced":8636504,"Frequency_Phase_Average":50,"Meter_Location_Current":0,"PowerApparent_S_Phase_1":9.6,"PowerApparent_S_Phase_2":0,"PowerApparent_S_Phase_3":0,"PowerApparent_S_Sum":9.6,"PowerFactor_Phase_1":0.973,"PowerFactor_Phase_2":0,"PowerFactor_Phase_3":0,"PowerFactor_Sum":0.881,"PowerReactive_Q_Phase_1":-2.2,"PowerReactive_Q_Phase_2":0,"PowerReactive_Q_Phase_3":0,"PowerReactive_Q_Sum":-2.2,"PowerReal_P_Phase_1":9.3,"PowerReal_P_Phase_2":0,"PowerReal_P_Phase_3":0,"PowerReal_P_Sum":9.3,"TimeStamp":1710287635,"Visible":1,"Voltage_AC_PhaseToPhase_12":400.5,"Voltage_AC_PhaseToPhase_23":403.6,"Voltage_AC_PhaseToPhase_31":401.4,"Voltage_AC_Phase_1":232.3,"Voltage_AC_Phase_2":230.2,"Voltage_AC_Phase_3":233.6}},"Head":{"RequestArguments":{"DeviceClass":"Meter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:53:55+01:00"}} 2024-03-13 00:53:56.142 - �[32minfo�[39m: host.raspberrypi instance system.adapter.fronius.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION) 2024-03-13 00:53:58.138 - �[32minfo�[39m: host.raspberrypi instance system.adapter.fronius.0 started with pid 200168 2024-03-13 00:53:59.405 - �[34mdebug�[39m: fronius.0 (200168) Redis Objects: Use Redis connection: 127.0.0.1:9001 2024-03-13 00:53:59.462 - �[34mdebug�[39m: fronius.0 (200168) Objects client ready ... initialize now 2024-03-13 00:53:59.465 - �[34mdebug�[39m: fronius.0 (200168) Objects create System PubSub Client 2024-03-13 00:53:59.467 - �[34mdebug�[39m: fronius.0 (200168) Objects create User PubSub Client 2024-03-13 00:53:59.516 - �[34mdebug�[39m: fronius.0 (200168) Objects client initialize lua scripts 2024-03-13 00:53:59.525 - �[34mdebug�[39m: fronius.0 (200168) Objects connected to redis: 127.0.0.1:9001 2024-03-13 00:53:59.561 - �[34mdebug�[39m: fronius.0 (200168) Redis States: Use Redis connection: 127.0.0.1:9000 2024-03-13 00:53:59.578 - �[34mdebug�[39m: fronius.0 (200168) States create System PubSub Client 2024-03-13 00:53:59.580 - �[34mdebug�[39m: fronius.0 (200168) States create User PubSub Client 2024-03-13 00:53:59.649 - �[34mdebug�[39m: fronius.0 (200168) States connected to redis: 127.0.0.1:9000 2024-03-13 00:53:59.815 - �[32minfo�[39m: fronius.0 (200168) starting. Version 2.0.2 in /opt/iobroker/node_modules/iobroker.fronius, node: v20.11.1, js-controller: 5.0.19 2024-03-13 00:53:59.978 - �[34mdebug�[39m: fronius.0 (200168) requestType https:// is not working! Now trying with http:// 2024-03-13 00:54:00.137 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetActiveDeviceInfo.cgi?DeviceClass=System: {"Body":{"Data":{"Inverter":{"1":{"DT":99}},"Meter":{"1":{"DT":-1,"Serial":"2131035562"}},"Ohmpilot":{},"SensorCard":{},"Storage":{},"StringControl":{}}},"Head":{"RequestArguments":{"DeviceClass":"System"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.138 - �[34mdebug�[39m: fronius.0 (200168) Current result of System deviceINFO: {"Inverter":{"1":{"DT":99}},"Meter":{"1":{"DT":-1,"Serial":"2131035562"}},"Ohmpilot":{},"SensorCard":{},"Storage":{},"StringControl":{}} 2024-03-13 00:54:00.139 - �[34mdebug�[39m: fronius.0 (200168) The current system configuration is up to date 2024-03-13 00:54:00.329 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetLoggerInfo.cgi: {"Body":{"LoggerInfo":{"CO2Factor":0.5299999713897705,"CO2Unit":"kg","CashCurrency":"EUR","CashFactor":0.07999999821186066,"DefaultLanguage":"en","DeliveryFactor":0.3499999940395355,"HWVersion":"2.4D","PlatformID":"wilma","ProductID":"fronius-hybrid","SWVersion":"1.30.1-3","TimezoneLocation":"Vienna","TimezoneName":"CET","UTCOffset":3600,"UniqueID":"239.25145"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.434 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetLoggerInfo.cgi: {"Body":{"LoggerInfo":{"CO2Factor":0.5299999713897705,"CO2Unit":"kg","CashCurrency":"EUR","CashFactor":0.07999999821186066,"DefaultLanguage":"en","DeliveryFactor":0.3499999940395355,"HWVersion":"2.4D","PlatformID":"wilma","ProductID":"fronius-hybrid","SWVersion":"1.30.1-3","TimezoneLocation":"Vienna","TimezoneName":"CET","UTCOffset":3600,"UniqueID":"239.25145"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.449 - �[34mdebug�[39m: fronius.0 (200168) Object creation will be done for 1 times 2024-03-13 00:54:00.590 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=3PInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"3PInverterData","DeviceClass":"Inverter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.663 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetPowerFlowRealtimeData.fcgi: {"Body":{"Data":{"Inverters":{"1":{"Battery_Mode":"suspended","DT":99,"E_Day":1309.5999755859375,"E_Total":21246630,"E_Year":262666.5,"P":0,"SOC":5}},"Site":{"BatteryStandby":true,"E_Day":1309.6000000000001,"E_Total":21246629.8,"E_Year":262666.5,"Meter_Location":"grid","Mode":"bidirectional","P_Akku":null,"P_Grid":9,"P_Load":-9,"P_PV":null,"rel_Autonomy":0,"rel_SelfConsumption":null},"Version":"12"}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.786 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetInverterInfo.cgi: {"Body":{"Data":{"1":{"CustomName":"&#68;&#114;&#46;&#32;&#84;&#104;&#111;&#109;&#97;&#115;&#32;&#71;&#101;&#105;&#103;&#108;","DT":99,"ErrorCode":0,"PVPower":5660,"Show":1,"StatusCode":3,"UniqueID":"1123205"}}},"Head":{"RequestArguments":{},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.812 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetOhmPilotRealtimeData.cgi?Scope=System: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DeviceClass":"OhmPilot","Scope":"System"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.888 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=CommonInverterData: {"Body":{"Data":{"DAY_ENERGY":{"Unit":"Wh","Value":1309},"DeviceStatus":{"ErrorCode":0,"LEDColor":0,"LEDState":0,"MgmtTimerRemainingTime":-1,"StateToReset":false,"StatusCode":3},"IDC":{"Unit":"A","Value":0},"TOTAL_ENERGY":{"Unit":"Wh","Value":21246629},"UDC":{"Unit":"V","Value":37.1},"YEAR_ENERGY":{"Unit":"Wh","Value":262666}}},"Head":{"RequestArguments":{"DataCollection":"CommonInverterData","DeviceClass":"Inverter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:00.912 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=1&DataCollection=MinMaxInverterData: {"Body":{"Data":{}},"Head":{"RequestArguments":{"DataCollection":"MinMaxInverterData","DeviceClass":"Inverter","Scope":"Device"},"Status":{"Code":6,"Reason":"CGI-Args: Invalid parameter 'MinMaxInverterData' for attribute 'DataCollection' (use 'CumulationInverterData', 'CommonInverterData' or '3PInverterData' )","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}} 2024-03-13 00:54:01.013 - �[34mdebug�[39m: fronius.0 (200168) Response to http://192.168.25.180/solar_api/v1/GetMeterRealtimeData.cgi?Scope=Device&DeviceId=1: {"Body":{"Data":{"Current_AC_Phase_1":0.079,"Current_AC_Phase_2":0,"Current_AC_Phase_3":0,"Current_AC_Sum":0.079,"Details":{"Manufacturer":"Fronius","Model":"Smart Meter TS 65A-3","Serial":"2131035562"},"Enable":1,"EnergyReactive_VArAC_Sum_Consumed":70839,"EnergyReactive_VArAC_Sum_Produced":41452,"EnergyReal_WAC_Minus_Absolute":8636504,"EnergyReal_WAC_Plus_Absolute":212094,"EnergyReal_WAC_Sum_Consumed":212094,"EnergyReal_WAC_Sum_Produced":8636504,"Frequency_Phase_Average":50,"Meter_Location_Current":0,"PowerApparent_S_Phase_1":9.6,"PowerApparent_S_Phase_2":0,"PowerApparent_S_Phase_3":0,"PowerApparent_S_Sum":9.6,"PowerFactor_Phase_1":0.973,"PowerFactor_Phase_2":0,"PowerFactor_Phase_3":0,"PowerFactor_Sum":0.878,"PowerReactive_Q_Phase_1":-2.2,"PowerReactive_Q_Phase_2":0,"PowerReactive_Q_Phase_3":0,"PowerReactive_Q_Sum":-2.2,"PowerReal_P_Phase_1":9.3,"PowerReal_P_Phase_2":0,"PowerReal_P_Phase_3":0,"PowerReal_P_Sum":9.3,"TimeStamp":1710287640,"Visible":1,"Voltage_AC_PhaseToPhase_12":400.4,"Voltage_AC_PhaseToPhase_23":403.5,"Voltage_AC_PhaseToPhase_31":401.4,"Voltage_AC_Phase_1":232.3,"Voltage_AC_Phase_2":230.1,"Voltage_AC_Phase_3":233.6}},"Head":{"RequestArguments":{"DeviceClass":"Meter","DeviceId":"1","Scope":"Device"},"Status":{"Code":0,"Reason":"","UserMessage":""},"Timestamp":"2024-03-13T00:54:00+01:00"}}

Wäre es möglich, den alten Adapter mit einem neuen Namen zu versehen, um beide Versionen zu installieren? Ich könnte dann den Symo Hybrid mit der alten Version betreiben und den Gen24 mit V.2.x.x. Ich selbst habe leider überhaupt keine Ahnung wie das geht.
Danke Thomas

nkleber78 added a commit to nkleber78/ioBroker.fronius that referenced this issue Mar 15, 2024
iobroker-community-adapters#374 Fixed the  issue by better handling empty or null objects. In this specific case it was about an empty object
@nkleber78
Copy link
Collaborator

Hallo @geigl
magst du mal die Version von meinem Repo installieren und testen ob das Problem jetzt weg ist?
https://github.com/nkleber78/ioBroker.fronius

@geigl
Copy link
Author

geigl commented Mar 16, 2024 via email

@geigl
Copy link
Author

geigl commented Mar 19, 2024

Hallo Norbert,
der Fehler tritt nicht mehr auf.
Vielen lieben Dank für deine Arbeit am Adapter

@geigl
Copy link
Author

geigl commented Jul 3, 2024

Hallo @geigl magst du mal die Version von meinem Repo installieren und testen ob das Problem jetzt weg ist? https://github.com/nkleber78/ioBroker.fronius

Hallo Norbert, es gibt keine Fehlermeldungen mehr. Deine Version hat die selbe Versionsnummer wie die aktuelle Stable-Version. Kannst du deine mit einer neuen Nummer in das Stable-Repo überleiten?
LG
Thomas

@mcm1957
Copy link
Member

mcm1957 commented Jul 24, 2024

Hallo @geigl magst du mal die Version von meinem Repo installieren und testen ob das Problem jetzt weg ist? https://github.com/nkleber78/ioBroker.fronius

Hallo Norbert, es gibt keine Fehlermeldungen mehr. Deine Version hat die selbe Versionsnummer wie die aktuelle Stable-Version. Kannst du deine mit einer neuen Nummer in das Stable-Repo überleiten? LG Thomas

Installationen von GitHub haben prinzipiell keine definierte Versionsnummer. Bei eine GitHub Installation ist die Releaseangabe irrelevant. Normalerweise wird eine die Versionsnummer erst im Zuge des Releases auf npm festgelegt.

Und zur Sache selbst:
Release 2.1.1 ist unterwegs ins LATEST Repo. Bitte testen und um Feedback. Codemäßig sollte sie idents zur Version von @nkleber78 sein. DANKE für den Fixe und den PR (der bei mir leider untergegangen ist - daher die Verzögerung).

@mcm1957
Copy link
Member

mcm1957 commented Jul 24, 2024

fixed with 2.1.1

mcm1957 added a commit that referenced this issue Jul 24, 2024
* (nkleber78) Better handling of empty objects [#374]
* (mcm1957) Some issues reported by adapter checker have been fixed.
* (mcm1957) Dependencies have been updated.
@geigl
Copy link
Author

geigl commented Jul 25, 2024

Teste ich gerne, ich gebe dann in ein paar Tagen eine Rückmeldung

@geigl
Copy link
Author

geigl commented Jul 29, 2024

Ich habe in den letzten Tagen keine Fehlermeldungen mehr erhalten.
Danke für die tolle Arbeit.

@mcm1957
Copy link
Member

mcm1957 commented Jul 29, 2024

DANKE fürs Feedback.
Ok, dann schließe ich hier mal.
Bitte melden wenn doch noch was nicht funktioniert. Oder ein neues Issue mit akteullen Daten öffnen.

@mcm1957 mcm1957 closed this as completed Jul 29, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Projects
None yet
Development

No branches or pull requests

3 participants