Merge pull request #124 from iqm-finland/update-circuit-duration-check
Browse files Browse the repository at this point in the history
Upgrade to iqm-client 16.0
  • Loading branch information
ollityrkko authored Feb 13, 2024
2 parents 139058b + 972c5ad commit 754962f
Show file tree
Hide file tree
Showing 5 changed files with 26 additions and 17 deletions.
7 changes: 7 additions & 0 deletions CHANGELOG.rst
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,13 @@
Changelog
=========

Version 13.0
============

* Require iqm-client >= 16.0.
* Remove parameter ``circuit_duration_check`` from ``IQMSampler``.
* Add parameter ``max_circuit_duration_over_t2`` to ``IQMSampler``.

Version 12.2
============

Expand Down
16 changes: 8 additions & 8 deletions docs/user_guide.rst
Original file line number Diff line number Diff line change
Expand Up @@ -279,13 +279,13 @@ The below table summarises the currently available options:
- "f7d9642e-b0ca-4f2d-af2a-30195bd7a76d"
- Indicates the calibration set to use. Defaults to `None`, which means the IQM server will use the best
available calibration set automatically.
* - `circuit_duration_check`
- bool
- False
- Enable or disable server-side circuit duration checks. The default value is `True`, which means if any job is
estimated to take unreasonably long compared to the coherence times of the qubits, or too long in wall-clock
time, the server will reject it. This option can be used to disable this behaviour. In normal use, the
circuit duration check should always remain enabled.
* - `max_circuit_duration_over_t2`
- float
- 1.0
- Set server-side circuit disqualification threshold. If any circuit in a job is estimated to take longer than the
shortest T2 time of any qubit used in the circuit multiplied by this value, the server will reject the job.
Setting this value to ``0.0`` will disable circuit duration check.
The default value ``None`` means the server default value will be used.
* - `heralding_mode`
- :py:class:`~iqm_client.iqm_client.HeraldingMode`
- "zeros"
Expand All @@ -298,7 +298,7 @@ For example if you would like to use a particular calibration set, you can provi
sampler = IQMSampler(iqm_server_url, calibration_set_id="f7d9642e-b0ca-4f2d-af2a-30195bd7a76d")
The same applies for `heralding_mode` and `circuit_duration_check`. The sampler will by default use an
The same applies for `heralding_mode` and `max_circuit_duration_over_t2`. The sampler will by default use an
:class:`.IQMDevice` created based on architecture data obtained from the server, which is then available in the
:attr:`.IQMSampler.device` property. Alternatively, the device can be specified directly with the ``device`` argument.

Expand Down
2 changes: 1 addition & 1 deletion pyproject.toml
Original file line number Diff line number Diff line change
Expand Up @@ -22,7 +22,7 @@ dependencies = [
"numpy",
"cirq-core[contrib] ~= 1.2",
"ply", # Required by cirq.contrib.qasm_import
"iqm-client >= 15.2, < 16.0"
"iqm-client >= 16.0, < 17.0"
]

[project.urls]
Expand Down
10 changes: 6 additions & 4 deletions src/iqm/cirq_iqm/iqm_sampler.py
Original file line number Diff line number Diff line change
Expand Up @@ -57,7 +57,9 @@ class IQMSampler(cirq.work.Sampler):
ID of the calibration set to use. If ``None``, use the latest one.
run_sweep_timeout:
timeout to poll sweep results in seconds.
circuit_duration_check: whether to enable or disable server-side circuit duration check
max_circuit_duration_over_t2: Circuits are disqualified on the server if they are longer than
this ratio of the T2 time of the qubits. If set to 0.0, no circuits are disqualified.
If set to None the server default value is used.
heralding_mode: Heralding mode to use during execution.
Keyword Args:
Expand All @@ -76,7 +78,7 @@ def __init__(
*,
calibration_set_id: Optional[UUID] = None,
run_sweep_timeout: Optional[int] = None,
circuit_duration_check: bool = True,
max_circuit_duration_over_t2: Optional[float] = None,
heralding_mode: HeraldingMode = HeraldingMode.NONE,
**user_auth_args, # contains keyword args auth_server_url, username and password
):
Expand All @@ -88,7 +90,7 @@ def __init__(
self._device = device
self._calibration_set_id = calibration_set_id
self._run_sweep_timeout = run_sweep_timeout
self._circuit_duration_check = circuit_duration_check
self._max_circuit_duration_over_t2 = max_circuit_duration_over_t2
self._heralding_mode = heralding_mode

@property
Expand Down Expand Up @@ -175,7 +177,7 @@ def _send_circuits(
serialized_circuits,
calibration_set_id=self._calibration_set_id,
shots=repetitions,
circuit_duration_check=self._circuit_duration_check,
max_circuit_duration_over_t2=self._max_circuit_duration_over_t2,
heralding_mode=self._heralding_mode,
)
timeout_arg = [self._run_sweep_timeout] if self._run_sweep_timeout is not None else []
Expand Down
8 changes: 4 additions & 4 deletions tests/test_iqm_sampler.py
Original file line number Diff line number Diff line change
Expand Up @@ -79,7 +79,7 @@ def submit_circuits_default_kwargs() -> dict:
return {
'calibration_set_id': None,
'shots': 1,
'circuit_duration_check': True,
'max_circuit_duration_over_t2': None,
'heralding_mode': HeraldingMode.NONE,
}

Expand Down Expand Up @@ -137,7 +137,7 @@ def test_run_sweep_has_duration_check_enabled_by_default(
client = mock(IQMClient)
sampler = IQMSampler(base_url, Adonis())
run_result = RunResult(status=Status.READY, measurements=[{'some stuff': [[0], [1]]}], metadata=iqm_metadata)
kwargs = submit_circuits_default_kwargs | {'circuit_duration_check': True}
kwargs = submit_circuits_default_kwargs | {'max_circuit_duration_over_t2': None}
when(client).submit_circuits(ANY, **kwargs).thenReturn(job_id)
when(client).wait_for_results(job_id).thenReturn(run_result)

Expand All @@ -153,9 +153,9 @@ def test_run_sweep_executes_circuit_with_duration_check_disabled(
base_url, circuit_physical, iqm_metadata, submit_circuits_default_kwargs, job_id
):
client = mock(IQMClient)
sampler = IQMSampler(base_url, Adonis(), circuit_duration_check=False)
sampler = IQMSampler(base_url, Adonis(), max_circuit_duration_over_t2=0.0)
run_result = RunResult(status=Status.READY, measurements=[{'some stuff': [[0], [1]]}], metadata=iqm_metadata)
kwargs = submit_circuits_default_kwargs | {'circuit_duration_check': False}
kwargs = submit_circuits_default_kwargs | {'max_circuit_duration_over_t2': 0.0}
when(client).submit_circuits(ANY, **kwargs).thenReturn(job_id)
when(client).wait_for_results(job_id).thenReturn(run_result)

Expand Down

0 comments on commit 754962f