Modification of pipe.py for handling data that was applied 'nmrPipe -fn EXT' in z-dim #92
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
3D nmrpipe file that was applied 'nmrPipe -fn EXT...' in z-dim could not be loaded by nmrglue.pipe.read().
I think, the trouble was originated length of z-dim was given by FDF*FTSIZE or FDF*TDSIZE. nmrPipe doesn't touch those parameters even EXT was applied. I would suggest using FDF*X1 and FDF*XN parameters for EXT applied data.