APU ENG CRANK PANEL - LED violates JLC constraints #680

Closed
4 of 20 tasks
Exprezz0 opened this issue Apr 13, 2023 · 3 comments
Closed
4 of 20 tasks

APU ENG CRANK PANEL - LED violates JLC constraints #680

Exprezz0 opened this issue Apr 13, 2023 · 3 comments
Assignees
Labels
Category: ECAD Electrical CAD/PCB HW Design Category: MCAD Mechanical CAD Priority: High Type: Bug/Obsolesce Something isn't working/Part no longer available for sale

Comments

@Exprezz0
Copy link
Contributor

Exprezz0 commented Apr 13, 2023

Summary:

The placement of an LED located on the APU ENG CRANK Panel, specifically the superier LED that lights up "L" for the engine crank switch falls within the boundaries of one of the mounting holes for the panel and the switch itself.

Expected Results/How It Should Work:

1: LED should be placed on the PCBs in order to meet JLC production requirements, despite it making through assembly in previous revisions.
2: LED should be offset and not placed directly behind engraving on the legend panel.
3: LED should be placed in a matter that allows complete connection.

Actual Results/How It Does Work:

image
Due to board constraints, the +5v pad and GND pad over lap the keepout zone for both the 6x32 mounting screw hole and mounting hole for 631H toggle switch. LED needs to me moved, removed, or rotated in order to fit within the constraints. Unable to currently get +5v power to the LED without moving.

More Information

Add an "X" in the square brackets to check the applicable checkboxs.

Category:

Check one or more items.

  • MCAD (SolidWorks)
  • ECAD (PCB Design or other electrical hardware)
  • Software - Sketch
  • Software - DCS-BIOS
  • Software - Library

Type:

Check one item.

  • Bug
  • Feature Enhancement
  • Maintenance
  • Question
  • Documentation

Applicable End Item:

Check one item.

  • Top Level Assembly
  • Lower Instrument Panel (LIP)
  • Main Instrument Panel (MIP)
  • Left Console
  • Right Console
  • Seat
  • Center Tub
  • Flight Stick
  • Throttle
  • General Software

Associated Filename(s):

(ECAD) APU ENG CRANK PANEL.kicad_pcb
(ECAD) APU ENG CRANK PANEL.kicad_sch
(MCAD) OH4A5A2-11 - APU ENG CRANK BACKPLATE

@Exprezz0 Exprezz0 self-assigned this Apr 13, 2023
@Exprezz0 Exprezz0 added Type: Bug/Obsolesce Something isn't working/Part no longer available for sale Category: MCAD Mechanical CAD Category: ECAD Electrical CAD/PCB HW Design Category: Component Sketch Software (PCB or Interfacing) Status: In Progress someone took over the issue or there is already a PR Status: Revision Needed for issues requiring a new revision to existing part due to problem found Priority: High labels Apr 13, 2023
@Exprezz0
Copy link
Contributor Author

Exprezz0 commented Apr 13, 2023

  • PCB Design (Silkscreen, DRC)
  • Schematic
  • JLC Manufacturing Files
  • STEP file
  • PNGs
  • Back Plate (MCAD)

@jrsteensen jrsteensen removed Category: Component Sketch Software (PCB or Interfacing) Status: In Progress someone took over the issue or there is already a PR Status: Revision Needed for issues requiring a new revision to existing part due to problem found labels Apr 13, 2023
@jrsteensen jrsteensen added this to the v1.0.0-beta1 (Beta 1) milestone Apr 13, 2023
@kbastronomics
Copy link
Collaborator

I think the constraint should only be on the bottom side of the board not the top where the components are.
I know this is possible in other ecad software, not sure about kiCAD though

Exprezz0 added a commit to Exprezz0/OpenHornet that referenced this issue Apr 13, 2023
 APU ENG CRANK Panel 100% ready for release.
Renamed from "APU PANEL" to "APU ENG CRANK PANEL" to match nomenclature
Transitioned to K7.
Schematic updated to standard.  DRC complete
PCB board updated with fix for issue jrsteensen#680.  DRC complete
Manufacturing files regenerated.
STEP and PNGs updated

OH Symbols and Footprints libraries updated with minor fixes to metadata
@Exprezz0
Copy link
Contributor Author

APU ENG CRANK Panel has been fixed. Saved and committed as: 408c4cb

PCB Model has been added and updated to F360, renamed to updated nomenclature, and backplate adjusted to accept new PCB. Saved as v18.

Mechanical files/Drawings are ready to be updated.