.. seo:: :description: Instructions for setting up NILAN Modbus. :image: nilan.png :keywords: NILAN Ventilation
.. note::
This page is incomplete and could some work. If you want to contribute, please read the
:doc:`contributing guide </guides/contributing>`. This page is missing:
- An image for the front page.
- Images/screenshots/example configs of this device being used in action.
The sensor can be connected in various configurations - please see the manufacturer's website <https://en.nilan.dk/en-gb/frontpage/download>
__
for more information.
.. warning::
This is only working for NILAN Light models.
The communication with this integration is done over a :ref:UART bus <uart>
.
You must therefore have a uart:
entry in your configuration with both the TX and RX pins set
to some pins on your board and the baud rate set to 9600.
.. code-block:: yaml
# Example configuration entry
uart:
rx_pin: D1
tx_pin: D2
baud_rate: 9600
sensor:
- platform: nilan //testnilan
filterdays:
name: "Time for filter change"
update_interval: 60s
- update_interval (Optional, :ref:
config-time
): The interval to check the sensor. Defaults to60s
. - address (Optional, int): The address of the sensor if multiple sensors are attached to
the same UART bus. You will need to set the address of each device manually. Defaults to
30
.