energy-management-app: Add instructions for Water Heater App using ch…
Browse files Browse the repository at this point in the history
…ip-tool and TestEventTriggers (project-chip#36307)

* energy-management-app: Document instructions for Water Heater TestEventTriggers using chip-tool

* Restyled by prettier-markdown

* Update examples/energy-management-app/linux/README.md

Co-authored-by: Andrei Litvin <andy314@gmail.com>

* Update examples/energy-management-app/linux/README.md

Co-authored-by: Andrei Litvin <andy314@gmail.com>

* Restyled by prettier-markdown

---------

Co-authored-by: Restyled.io <commits@restyled.io>
Co-authored-by: Andrei Litvin <andy314@gmail.com>
  • Loading branch information
3 people authored Oct 31, 2024
1 parent daf2bce commit f212d60
Showing 1 changed file with 59 additions and 0 deletions.
59 changes: 59 additions & 0 deletions examples/energy-management-app/linux/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -552,3 +552,62 @@ When we re-read the events:
state was `kPluggedInCharging` prior to the EV being not detected (normally
in a graceful shutdown this would be `kPluggedInNoDemand` or
`kPluggedInDemand`).

## Water Heater App: Interaction using the chip-tool and TestEventTriggers

This section demonstrates how to run the Water Heater application and interact
with it using the `chip-tool` and `TestEventTriggers`. By default (at the time
of writing), the WaterHeater app does not configure some of its attributes with
simulated values (most default to 0). The steps below set the
[default](https://github.com/project-chip/connectedhomeip/blob/master/src/app/clusters/water-heater-management-server/WaterHeaterManagementTestEventTriggerHandler.h#L47)
`TestEventTrigger` which
`Simulate installation in a 100L tank full of water at 20C, with a target temperature of 60C, in OFF mode`.

Step-by-step:

1. Build the `energy-management-app` for linux:

```
./scripts/build/build_examples.py --target linux-x64-energy-management-no-ble build
```
1. Run the Water Heater application:
```
rm /tmp/chip_* && ./out/linux-x64-energy-management-no-ble/chip-energy-management-app --application water-heater --trace-to json:log --enable-key 000102030405060708090a0b0c0d0e0f
```
1. Commission with chip-tool as node `0x12344321`:
```
./out/linux-x64-chip-tool-no-ble/chip-tool pairing code 0x12344321 MT:-24J0AFN00KA0648G00
```
1. Read the `TankVolume` attribute (expect 0 by default):
```
./out/linux-x64-chip-tool-no-ble/chip-tool waterheatermanagement read tank-volume 0x12344321 2 | grep TOO
[1730306361.511] [2089549:2089552] [TOO] TankVolume: 0
```
1. Set the default TestEventTrigger (`0x0094000000000000`):
- `0x0094000000000000` corresponds to `kBasicInstallationTestEvent` from
`WaterHeadermanagementTestEventTriggerHandler.h`
- `hex:00010203...0e0f` is the `--enable-key` passed to the startup of
chip-energy-management-app
- `0x12344321` is the node-id that the app was commissioned on
- final `0` is the endpoint on which the `GeneralDiagnostics` cluster exists
to call the `TestEventTrigger` command
```
./out/linux-x64-chip-tool-no-ble/chip-tool generaldiagnostics test-event-trigger hex:000102030405060708090a0b0c0d0e0f 0x0094000000000000 0x12344321 0
```
1. Read TankVolume attribute again (now expect 100):
```
./out/linux-x64-chip-tool-no-ble/chip-tool waterheatermanagement read tank-volume 0x12344321 2 | grep TOO
[1730312762.703] [2153606:2153609] [TOO] TankVolume: 100
```