This project is no longer under active maintenance. It is read-only, but you can still clone or fork the repo. Check here for further info. Please contact innereye_info@service.microsoft.com if you run into trouble with the "Archived" state of the repo.
InnerEye-DeepLearning (IE-DL) is a toolbox for easily training deep learning models on 3D medical images. Simple to run both locally and in the cloud with AzureML, it allows users to train and run inference on the following:
- Segmentation models.
- Classification and regression models.
- Any PyTorch Lightning model, via a bring-your-own-model setup.
In addition, this toolbox supports:
- Cross-validation using AzureML, where the models for individual folds are trained in parallel. This is particularly important for the long-running training jobs often seen with medical images.
- Hyperparameter tuning using Hyperdrive.
- Building ensemble models.
- Easy creation of new models via a configuration-based approach, and inheritance from an existing architecture.
For all documentation, including setup guides and APIs, please refer to the IE-DL Read the Docs site.
This quick setup assumes you are using a machine running Ubuntu with Git, Git LFS, Conda and Python 3.7+ installed. Please refer to the setup guide for more detailed instructions on getting InnerEye set up with other operating systems and installing the above prerequisites.
-
Clone the InnerEye-DeepLearning repo by running the following command:
git clone --recursive https://github.com/microsoft/InnerEye-DeepLearning && cd InnerEye-DeepLearning
-
Create and activate your conda environment:
conda env create --file environment.yml && conda activate InnerEye
-
Verify that your installation was successful by running the HelloWorld model (no GPU required):
python InnerEye/ML/runner.py --model=HelloWorld
If the above runs with no errors: Congratulations! You have successfully built your first model using the InnerEye toolbox.
If it fails, please check the troubleshooting page on the Wiki.
We offer a companion set of open-sourced tools that help to integrate trained CT segmentation models with clinical software systems:
- The InnerEye-Gateway is a Windows service running in a DICOM network, that can route anonymized DICOM images to an inference service.
- The InnerEye-Inference component offers a REST API that integrates with the InnerEye-Gateway, to run inference on InnerEye-DeepLearning models.
Details can be found here.
In combiniation with the power of AzureML, InnerEye provides the following benefits:
- Traceability: AzureML keeps a full record of all experiments that were executed, including a snapshot of the code. Tags are added to the experiments automatically, that can later help filter and find old experiments.
- Transparency: All team members have access to each other's experiments and results.
- Reproducibility: Two model training runs using the same code and data will result in exactly the same metrics. All sources of randomness are controlled for.
- Cost reduction: Using AzureML, all compute resources (virtual machines, VMs) are requested at the time of starting the training job and freed up at the end. Idle VMs will not incur costs. Azure low priority nodes can be used to further reduce costs (up to 80% cheaper).
- Scalability: Large numbers of VMs can be requested easily to cope with a burst in jobs.
Despite the cloud focus, InnerEye is designed to be able to run locally too, which is important for model prototyping, debugging, and in cases where the cloud can't be used. Therefore, if you already have GPU machines available, you will be able to utilize them with the InnerEye toolbox.
You are responsible for the performance, the necessary testing, and if needed any regulatory clearance for any of the models produced by this toolbox.
When using Project InnerEye open-source software (OSS) tools, please acknowledge with the following wording:
This project used Microsoft Research's Project InnerEye open-source software tools (https://aka.ms/InnerEyeOSS).
If you have any feature requests, or find issues in the code, please create an issue on GitHub.
Please send an email to InnerEyeInfo@microsoft.com if you would like further information about this project.
Oktay O., Nanavati J., Schwaighofer A., Carter D., Bristow M., Tanno R., Jena R., Barnett G., Noble D., Rimmer Y., Glocker B., O’Hara K., Bishop C., Alvarez-Valle J., Nori A.: Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers. JAMA Netw Open. 2020;3(11):e2027426. doi:10.1001/jamanetworkopen.2020.27426
Bannur S., Oktay O., Bernhardt M, Schwaighofer A., Jena R., Nushi B., Wadhwani S., Nori A., Natarajan K., Ashraf S., Alvarez-Valle J., Castro D. C.: Hierarchical Analysis of Visual COVID-19 Features from Chest Radiographs. ICML 2021 Workshop on Interpretable Machine Learning in Healthcare. https://arxiv.org/abs/2107.06618
Bernhardt M., Castro D. C., Tanno R., Schwaighofer A., Tezcan K. C., Monteiro M., Bannur S., Lungren M., Nori S., Glocker B., Alvarez-Valle J., Oktay. O: Active label cleaning for improved dataset quality under resource constraints. https://www.nature.com/articles/s41467-022-28818-3. Accompanying code InnerEye-DataQuality
This project welcomes contributions and suggestions. Most contributions require you to agree to a Contributor License Agreement (CLA) declaring that you have the right to, and actually do, grant us the rights to use your contribution. For details, visit https://cla.opensource.microsoft.com.
When you submit a pull request, a CLA bot will automatically determine whether you need to provide a CLA and decorate the PR appropriately (e.g., status check, comment). Simply follow the instructions provided by the bot. You will only need to do this once across all repos using our CLA.
This project has adopted the Microsoft Open Source Code of Conduct. For more information see the Code of Conduct FAQ or contact opencode@microsoft.com with any additional questions or comments.
This toolbox is maintained by the Microsoft Medical Image Analysis team.