Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

zed: Add zedlet to power off slot when drive is faulted #15200

Merged
merged 1 commit into from
Aug 24, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
61 changes: 61 additions & 0 deletions cmd/zed/zed.d/statechange-slot_off.sh
Original file line number Diff line number Diff line change
@@ -0,0 +1,61 @@
#!/bin/sh
#
# Turn off disk's enclosure slot if it becomes FAULTED.
#
# Bad SCSI disks can often "disappear and reappear" causing all sorts of chaos
# as they flip between FAULTED and ONLINE. If
# ZED_POWER_OFF_ENCLOUSRE_SLOT_ON_FAULT is set in zed.rc, and the disk gets
# FAULTED, then power down the slot via sysfs:
#
# /sys/class/enclosure/<enclosure>/<slot>/power_status
#
# We assume the user will be responsible for turning the slot back on again.
#
# Note that this script requires that your enclosure be supported by the
# Linux SCSI Enclosure services (SES) driver. The script will do nothing
# if you have no enclosure, or if your enclosure isn't supported.
#
# Exit codes:
# 0: slot successfully powered off
# 1: enclosure not available
# 2: ZED_POWER_OFF_ENCLOUSRE_SLOT_ON_FAULT disabled
# 3: vdev was not FAULTED
# 4: The enclosure sysfs path passed from ZFS does not exist
# 5: Enclosure slot didn't actually turn off after we told it to

[ -f "${ZED_ZEDLET_DIR}/zed.rc" ] && . "${ZED_ZEDLET_DIR}/zed.rc"
. "${ZED_ZEDLET_DIR}/zed-functions.sh"

if [ ! -d /sys/class/enclosure ] ; then
# No JBOD enclosure or NVMe slots
exit 1
fi

if [ "${ZED_POWER_OFF_ENCLOUSRE_SLOT_ON_FAULT}" != "1" ] ; then
exit 2
fi

if [ "$ZEVENT_VDEV_STATE_STR" != "FAULTED" ] ; then
exit 3
fi

if [ ! -f "$ZEVENT_VDEV_ENC_SYSFS_PATH/power_status" ] ; then
exit 4
fi

echo "off" | tee "$ZEVENT_VDEV_ENC_SYSFS_PATH/power_status"

# Wait for sysfs for report that the slot is off. It can take ~400ms on some
# enclosures.
for i in $(seq 1 20) ; do
if [ "$(cat $ZEVENT_VDEV_ENC_SYSFS_PATH/power_status)" == "off" ] ; then
break
fi
sleep 0.1
done

if [ "$(cat $ZEVENT_VDEV_ENC_SYSFS_PATH/power_status)" != "off" ] ; then
exit 5
fi

zed_log_msg "powered down slot $ZEVENT_VDEV_ENC_SYSFS_PATH for $ZEVENT_VDEV_PATH"
5 changes: 5 additions & 0 deletions cmd/zed/zed.d/zed.rc
Original file line number Diff line number Diff line change
Expand Up @@ -142,3 +142,8 @@ ZED_SYSLOG_SUBCLASS_EXCLUDE="history_event"
# Disabled by default, 1 to enable and 0 to disable.
#ZED_SYSLOG_DISPLAY_GUIDS=1

##
# Power off the drive's slot in the enclosure if it becomes FAULTED. This can
# help silence misbehaving drives. This assumes your drive enclosure fully
# supports slot power control via sysfs.
#ZED_POWER_OFF_ENCLOUSRE_SLOT_ON_FAULT=1
Loading