HM605

AHT20_BMP280 logo

The HM605 is a very practical and cheap power supply manufactured by etommens and sold through Hanmatek OEM. It is very easy to use and has a fairly low ripple voltage. And with a few simple steps, you can make it Modbus enabled.

What do to

AHT20_BMP280 logo AHT20_BMP280 logo

  • remove housing
  • remove display board
  • solder in a pin header
  • reassemble everything
  • check in Setup (long press on Voltage) that Modbus is active

How it works

  • use a TTL to USB with 3.3V logic level!!!
  • only GND (G) TX (T) and RX (R) are sufficient
  • TX and RX must be crossed
  • use a terminal programme of your choice
  • connect with 9600 8 N 2
  • send 01 03 00 10 00 01 85 CF as HEX
  • now you get the current voltage as a HEX value
  • more details in the ModBus-V2.2.pdf file

Example Output