MideaUART

work in progress....

Features supported by the appliance

The appliance reports which features are supported to be controlled and/or monitored via the UART interface as a response to the 0xB5 query. Which capabilities are reported differs per appliance and turns out to be not 100% correct for some appliances (e.g. Artel airconditioners report to support a left right fan while the vertical position has to changed manually).

Capability Values Description
autoSetHumidity boolean It is unclear what this capability means for the UART protocol.
autoMode boolean The Auto mode can be activated.
activeClean boolean The Active Clean mode can be dis/enabled.
breezeControl boolean The appliance supports 3 different modes to control the breeze.
buzzer boolean The appliance has a buzzer that can be controlled. Note: My appliance does not report this capability but I was still able to control the command notification buzzer via the beep status property.
coolMode boolean The Cool mode can be activated and the temperatureSetpoint can be set.
dimmableLight boolean The LED display can be toggled on and off.
dryMode boolean The Dry mode can be activated.
ecoMode boolean The Eco mode can be dis/enabled.
electricAuxHeating boolean It is unclear what this capability means for the UART protocol.
fanspeedControl boolean Fan speed can be specified.
frostProtectionMode boolean The Frost Protection Mode can be dis/enabled.
heatMode boolean The Heat mode can be activated and the temperatureSetpoint can be set.
indoorHumidity boolean The indoor humidity is being reported.
leftrightFan boolean The vertical fan can be dis/enabled.
manualSetHumidity boolean The humiditySetpoint can be specified in Dry mode.
nestCheck boolean It is unclear what this capability means for the UART protocol.
nestNeedChange boolean It is unclear what this capability means for the UART protocol.
maxTempAuto temperature The maximum temperatureSetpoint supported in Auto mode. When not specified the default is 31°C.
maxTempCool temperature The maximum temperatureSetpoint supported in Cool mode. When not specified the default is 31°C.
maxTempHeat temperature The maximum temperatureSetpoint supported in Heat mode. When not specified the default is 31°C.
minTempAuto temperature The minimum temperatureSetpoint supported in Auto mode. When not specified the default is 16°C.
minTempCool temperature The minimum temperatureSetpoint supported in Cool mode. When not specified the default is 16°C.
minTempHeat temperature The minimum temperatureSetpoint supported in Heat mode. When not specified the default is 16°C.
oneKeyNoWindOnMe boolean ...
powerCal boolean The appliance can report power usage.
powerCalSetting boolean It is unclear what this capability means for the UART protocol.
silkyCool boolean The Silky Cool function can be dis/enabled.
smartEye boolean The intelligent eye function can be dis/enabled.
specialEco boolean The Eco mode can be dis/enabled.
turboCool boolean The Turbo mode can be dis/enabled while in Cool mode.
turboHeat boolean The Turbo mode can be dis/enabled while in Heat mode.
unitChangeable boolean The temperature unit can be changed from Celsius to Fahrenheit. Conversion between Fahrenheit and Celsius has to be done by the calling application, the UART protocol always uses Celsius for reporting and changing the setpoint. Note: Not all appliances report this capability correctly.
updownFan boolean The horizontal fan can be dis/enabled.
windOfMe boolean The Wind On Me mode can be dis/enabled.
windOnMe boolean The Wind Off Me mode can be dis/enabled.

Status properties

The status of the appliance is reported and can be controlled via the UART protocol using various properties. The following table shows all properties known, what possible values can be, which method can be used to set or get the value of the property, which appliance type supports the property.

Not all properties are supported by all types of appliances and by all models of these appliances.

Property Values Set Query Appliance Type Description
breezeType uint8_t
1: disable
2: breeze away
3: breeze mild
4: breezeless
setStatusCmdB1 getStatusCmdB1 Airconditioner The breeze mode.
catchCold boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
childSleep boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
cleanUp boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
coolFan boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
cosySleep boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
double_temp boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
dryClean boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
dusFull boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
ecoMode boolean setStatusCmd40 getStatusCmd41 Airconditioner Dis/enable Eco mode.
errorCode uint8_t - getStatusCmd41 Airconditioner Code describing the type of error. See below for possible errors.
exchangeAir boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
fanSpeed 0 - 100: %
102: Auto
setStatusCmd40 getStatusCmd41 Airconditioner Set fan speed.
feelOwn boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
frostProtectionMode boolean setStatusCmd40 getStatusCmd41 Airconditioner Dis/enable Frost Protection Mode. Can only be enabled in Heat mode.
humiditySetpoint uint8_t (30 - 90) setStatusCmd40 getStatusCmd41 Airconditioner Set the humidity setpoint. Can only be set in Dry mode.
indoorHumidity uint8_t (0 - 100) - getStatusCmdB1 Airconditioner The humidity measured by the indoor unit.
indoorTemperature float - getStatusCmd41 Airconditioner The temperature measured by the indoor unit.
inError boolean - getStatusCmd41 Airconditioner Flag indicating the appliance has an error. Use errorCode to determine the exact error.
leftrightFan boolean setStatusCmd40 getStatusCmd41 Airconditioner Status of the vertical fan (true = on).
light boolean toggleLight getStatusCmd41 Airconditioner Status of the LED display (true = on)
lowFrequencyFan boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown, might have something to do with eco mode.
mode uint8_t (0 - 6)
1: Auto
2: Cool
3: Dry
4: Heat:
5: Fan
6: Dry (custom)
setStatusCmd40 getStatusCmd41 Airconditioner The operational mode.
naturalFan boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
nightLight boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
offTimer boolean setStatusCmd40 getStatusCmd41 Airconditioner Dis/enable timer to turn off appliance.
offTimerHours uint8_t setStatusCmd40 getStatusCmd41 Airconditioner The number of hours set for the off timer.
offTimerMinutes uint8_t setStatusCmd40 getStatusCmd41 Airconditioner The number of minutes (within the hour) set for the off timer.
onTimer uint8_t setStatusCmd40 getStatusCmd41 Airconditioner Dis/enable timer to turn on appliance.
onTimerHours uint8_t setStatusCmd40 getStatusCmd41 Airconditioner The number of hours set for the on timer.
onTimerMinutes uint8_t setStatusCmd40 getStatusCmd41 Airconditioner The number of minutes (within the hour) set for the on timer.
outdoorTemperature float - getStatusCmd41 Airconditioner The outdoor temperature as measured by the outdoor unit. The unit reported is determined by the value of the temperatureUnit property.
peakElec boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
pmvMode uint8_t - getStatusCmd41 Airconditioner Probably the "Predictive Mean Vote", the experienced temperature. Not reported by any known appliances.
powerUsage unt16_t - getPowerUsage Airconditioner The power usage in Wh.
powerOn boolean setStatusCmd40 getStatusCmd41 Airconditioner Power status of the appliance.
ptcHeater boolean setStatusCmd40 getStatusCmd41 Airconditioner Status of the electrical heating support when available.
resume boolean setStatusCmd40 getStatusCmd41 Airconditioner Probably the status of the resume mode after recovered from a powerloss.
save boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
selfCosySleep boolean - getStatusCmd41 Airconditioner Unknown
selfFeelOwn boolean - getStatusCmd41 Airconditioner Unknown
setNewTemperature uint8_t setStatusCmd40 getStatusCmd41 Airconditioner Probably legacy support. When set > 0 this will override the temperatureSetpoint property.
sleepMode boolean setStatusCmd40 getStatusCmd41 Airconditioner The status of the sleep mode.
temperatureSetpoint float setStatusCmd40 getStatusCmd41 Airconditioner The temperature setpoint used in Cool and Heat mode.
temperatureUnit uint8_t
0: Celsius
1: Fahrenheit
setStatusCmd40 getStatusCmd41 Airconditioner Unit used to specify and present temperatures.
test2 boolean setStatusCmd40 getStatusCmd41 Airconditioner Unknown
timerMode uint8_t
0: Relative
Absolute
setStatusCmd40 getStatusCmd41 Airconditioner Mode used for the on and off timers. No appliances known that support the absolute mode.
turboMode boolean setStatusCmd40 getStatusCmd41 Airconditioner Turbo mode in Cool or Heat mode.
updownFan boolean setStatusCmd40 getStatusCmd41 Airconditioner Status of the horizontal swing.

Methods

Some method support the callback argument which either has to be NULL or the address of a function that must be called when the response from the appliance has been received. See the description of the Callback Handler for more details.

getCapabilities(HandlerFn callback)

This method can be used to update the list of supported features as reported by the appliance.

When the appliance responds successfully, the capabilities structure will be updated and can be examined. The full list of possibly supported features can be found here.

The appliance can report whether a feature is supported or not. Features not reported are assumed to be not supported.

Note: Not all appliances report all supported features correctly. My Midea appliance reports the leftrightFan capability while the position of the vertical swing can only be changed manually.

loop()

This method must be called from the main loop in order to handle all communication between the dongle and the appliance.

getPowerStatus(HandlerFn callback)

The getPowerStatus method will retrieve the current power usage from the appliance. When the appliance supports this feature it will report the powerCall capability.

The powerUsage property of the status structure will be updated based on the response from the appliance.

getStatusCmd41(HandlerFn callback)

This method requests a status update from the appliance.

getStatusCmdB1(HandlerFn callback)

setStatusCmd40(HandlerFn callback)

setStatusCmdB0(HandlerFn callback)

toggleLight(HandlerFn callback)

Callback handler

Methods that support callback handlers, expect either NULL as the callback handler or the address of a function that will be called when the response of the appliances is received or when a timeout occurs (2 seconds). The callback function must accept a uint8_t as argument which will contain a status code.

Status code Description
0 A valid response has been received from the appliance. The results are processed in the status or capabilities structure.
1 No response has been received from the appliance within 2 seconds. This either indicates the appliance was to busy to respond within this time, or the command or query is not supported.

Limitations

Direct position of the vertical and/or horizontal swing. Not all features could be tested on a real appliance. Pull requests and/or bug reports are welcome.

To do

Support for dehumidifiers en humidifiers.