Skip to content

Commit

Permalink
fix Priority Limit Calculation
Browse files Browse the repository at this point in the history
## V 1.102
### script
* fix Priority Limit Calculation in Priority Mode and Mixed Mode (#228)
* added a "Debug" Reader and DTU just for debugging.
### config
* added a "Debug" Reader and DTU just for debugging.
  • Loading branch information
reserve85 authored Sep 4, 2024
1 parent 33b9c09 commit 2151889
Show file tree
Hide file tree
Showing 3 changed files with 119 additions and 11 deletions.
7 changes: 7 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -1,5 +1,12 @@
# Changelog

## V 1.102
### script
* fix Priority Limit Calculation in Priority Mode and Mixed Mode (https://github.com/reserve85/HoymilesZeroExport/issues/228)
* added a "Debug" Reader and DTU just for debugging.
### config
* added a "Debug" Reader and DTU just for debugging.

## V 1.101
### script
* Bugfix newLimitSetpoint for OpenDTU (https://github.com/reserve85/HoymilesZeroExport/issues/235)
Expand Down
118 changes: 108 additions & 10 deletions HoymilesZeroExport.py
Original file line number Diff line number Diff line change
Expand Up @@ -15,7 +15,7 @@
# along with this program. If not, see <http://www.gnu.org/licenses/>.

__author__ = "Tobias Kraft"
__version__ = "1.101"
__version__ = "1.102"

import time
from requests.sessions import Session
Expand Down Expand Up @@ -120,27 +120,36 @@ def SetLimitWithPriority(pLimit):
SetLimitWithPriority.LastLimitAck = True
min_watt_all_inverters = GetMinWattFromAllInverters()
if (CastToInt(pLimit) <= min_watt_all_inverters):
pLimit = 0 # set only minWatt for every inv.
pLimit = min_watt_all_inverters # set only minWatt for every inv.
PublishGlobalState("limit", min_watt_all_inverters)
else:
PublishGlobalState("limit", CastToInt(pLimit))
RemainingLimit = CastToInt(pLimit)

# RemainingLimit -= GetMinWattFromAllBatteryInverters() #reserve the always additional min-Watt from active inverters

for j in range (1,6):
if GetMaxWattFromAllInvertersSamePrio(j) <= 0:
continue
if RemainingLimit >= GetMaxWattFromAllInvertersSamePrio(j):
LimitPrio = GetMaxWattFromAllInvertersSamePrio(j)
else:
LimitPrio = RemainingLimit
RemainingLimit = RemainingLimit - LimitPrio

LimitPrio -= GetMinWattFromBatteryInvertersWithLowerPriorities(j) # reserve the sum of minWatt from all Lower Priorities Inverters

for i in range(INVERTER_COUNT):
if (not AVAILABLE[i]) or (not HOY_BATTERY_GOOD_VOLTAGE[i]):
continue
if CONFIG_PROVIDER.get_battery_priority(i) != j:
continue

Factor = HOY_MAX_WATT[i] / GetMaxWattFromAllInvertersSamePrio(j)
NewLimit = CastToInt(LimitPrio*Factor)

NewLimit = LimitPrio - GetMinWattFromAllBatteryInvertersWithSamePriority(j)

NewLimit = CastToInt(NewLimit*Factor) + GetMinWatt(i)

NewLimit = ApplyLimitsToSetpointInverter(i, NewLimit)
if HOY_COMPENSATE_WATT_FACTOR[i] != 1:
logger.info('Ahoy: Inverter "%s": compensate Limit from %s Watt to %s Watt', NAME[i], CastToInt(NewLimit), CastToInt(NewLimit*HOY_COMPENSATE_WATT_FACTOR[i]))
Expand All @@ -157,6 +166,8 @@ def SetLimitWithPriority(pLimit):
if not DTU.WaitForAck(i, SET_LIMIT_TIMEOUT_SECONDS):
SetLimitWithPriority.LastLimitAck = False
LASTLIMITACKNOWLEDGED[i] = False

RemainingLimit -= LimitPrio
except:
logger.error("Exception at SetLimitWithPriority")
SetLimitWithPriority.LastLimitAck = False
Expand Down Expand Up @@ -191,7 +202,9 @@ def SetLimitMixedModeWithPriority(pLimit):
if RemainingLimit >= GetMaxInverterWattFromAllNonBatteryInverters():
nonBatteryInvertersLimit = GetMaxInverterWattFromAllNonBatteryInverters()
else:
nonBatteryInvertersLimit = RemainingLimit - GetMinWattFromAllBatteryInverters()
nonBatteryInvertersLimit = RemainingLimit

nonBatteryInvertersLimit -= GetMinWattFromAllBatteryInverters() #reserve the always additional min-Watt from following battery inverters

for i in range(INVERTER_COUNT):
if not AVAILABLE[i] or HOY_BATTERY_MODE[i]:
Expand Down Expand Up @@ -232,8 +245,9 @@ def SetLimitMixedModeWithPriority(pLimit):
if RemainingLimit >= batteryMaxWattSamePrio:
LimitPrio = batteryMaxWattSamePrio
else:
LimitPrio = RemainingLimit
RemainingLimit = RemainingLimit - LimitPrio
LimitPrio = RemainingLimit

LimitPrio -= GetMinWattFromBatteryInvertersWithLowerPriorities(j) # reserve the sum of minWatt from all Lower Priorities Inverters

for i in range(INVERTER_COUNT):
if (not HOY_BATTERY_MODE[i]):
Expand All @@ -242,8 +256,13 @@ def SetLimitMixedModeWithPriority(pLimit):
continue
if CONFIG_PROVIDER.get_battery_priority(i) != j:
continue

Factor = HOY_MAX_WATT[i] / batteryMaxWattSamePrio
NewLimit = CastToInt(LimitPrio*Factor)

NewLimit = LimitPrio - GetMinWattFromAllBatteryInvertersWithSamePriority(j)

NewLimit = CastToInt(NewLimit * Factor) + GetMinWatt(i)

NewLimit = ApplyLimitsToSetpointInverter(i, NewLimit)
if HOY_COMPENSATE_WATT_FACTOR[i] != 1:
logger.info('Ahoy: Inverter "%s": compensate Limit from %s Watt to %s Watt', NAME[i], CastToInt(NewLimit), CastToInt(NewLimit*HOY_COMPENSATE_WATT_FACTOR[i]))
Expand All @@ -260,6 +279,8 @@ def SetLimitMixedModeWithPriority(pLimit):
if not DTU.WaitForAck(i, SET_LIMIT_TIMEOUT_SECONDS):
SetLimitMixedModeWithPriority.LastLimitAck = False
LASTLIMITACKNOWLEDGED[i] = False

RemainingLimit -= LimitPrio
except:
logger.error("Exception at SetLimitMixedModeWithPriority")
SetLimitMixedModeWithPriority.LastLimitAck = False
Expand Down Expand Up @@ -641,7 +662,23 @@ def GetMinWattFromAllBatteryInverters():
if (not AVAILABLE[i]) or (not HOY_BATTERY_MODE[i]) or (not HOY_BATTERY_GOOD_VOLTAGE[i]):
continue
minWatt = minWatt + GetMinWatt(i)
return minWatt
return minWatt

def GetMinWattFromBatteryInvertersWithLowerPriorities(pPriority):
minWatt = 0
for i in range(INVERTER_COUNT):
if (not AVAILABLE[i]) or (not HOY_BATTERY_MODE[i]) or (not HOY_BATTERY_GOOD_VOLTAGE[i]) or (CONFIG_PROVIDER.get_battery_priority(i) <= pPriority):
continue
minWatt = minWatt + GetMinWatt(i)
return minWatt

def GetMinWattFromAllBatteryInvertersWithSamePriority(pPriority):
minWatt = 0
for i in range(INVERTER_COUNT):
if (not AVAILABLE[i]) or (not HOY_BATTERY_MODE[i]) or (not HOY_BATTERY_GOOD_VOLTAGE[i]) or (CONFIG_PROVIDER.get_battery_priority(i) != pPriority):
continue
minWatt = minWatt + GetMinWatt(i)
return minWatt

def GetMixedMode():
#if battery mode and custom priority use SetLimitWithPriority
Expand Down Expand Up @@ -895,6 +932,10 @@ def GetJson(self, path):
def GetPowermeterWatts(self):
ParsedData = self.GetJson('/rest')
return CastToInt(ParsedData['saldo'])

class DebugReader(Powermeter):
def GetPowermeterWatts(self):
return CastToInt(input("Enter Powermeter Watts: "))

class DTU(Powermeter):
def __init__(self, inverter_count: int):
Expand Down Expand Up @@ -1205,6 +1246,55 @@ def SetPowerStatus(self, pInverterId: int, pActive: bool):
response = self.GetResponseJson('/api/power/config', mySendStr)
if response['type'] != 'success':
raise Exception(f"Error: SetPowerStatus error: {response['message']}")

class DebugDTU(DTU):
def __init__(self, inverter_count: int):
super().__init__(inverter_count)

def GetACPower(self, pInverterId):
return CastToInt(input("Current AC-Power: "))

def CheckMinVersion(self):
return

def GetAvailable(self, pInverterId: int):
logger.info('Debug: Inverter "%s" Available: %s',NAME[pInverterId], True)
return True

def GetActualLimitInW(self, pInverterId: int):
return CastToInt(input("Current InverterLimit: "))

def GetInfo(self, pInverterId: int):
SERIAL_NUMBER[pInverterId] = str(pInverterId)
NAME[pInverterId] = str(pInverterId)
TEMPERATURE[pInverterId] = '0 degC'
logger.info('Debug: Inverter "%s" / serial number "%s" / temperature %s',NAME[pInverterId],SERIAL_NUMBER[pInverterId],TEMPERATURE[pInverterId])

def GetTemperature(self, pInverterId: int):
TEMPERATURE[pInverterId] = 0
logger.info('Debug: Inverter "%s" temperature: %s',NAME[pInverterId],TEMPERATURE[pInverterId])

def GetPanelMinVoltage(self, pInverterId: int):
logger.info('Lowest panel voltage inverter "%s": %s Volt',NAME[pInverterId],90)
return 90

def WaitForAck(self, pInverterId: int, pTimeoutInS: int):
return True

def SetLimit(self, pInverterId: int, pLimit: int):
logger.info('Debug: Inverter "%s": setting new limit from %s Watt to %s Watt',NAME[pInverterId],CastToInt(CURRENT_LIMIT[pInverterId]),CastToInt(pLimit))
CURRENT_LIMIT[pInverterId] = pLimit

def SetPowerStatus(self, pInverterId: int, pActive: bool):
if pActive:
logger.info('Debug: Inverter "%s": Turn on',NAME[pInverterId])
else:
logger.info('Debug: Inverter "%s": Turn off',NAME[pInverterId])

def Authenticate(self):
logger.info('Debug: Authenticating...')
self.Token = '12345'
logger.info('Debug: Authenticating successful, received Token: %s', self.Token)

class Script(Powermeter):
def __init__(self, file: str, ip: str, user: str, password: str):
Expand Down Expand Up @@ -1383,6 +1473,8 @@ def CreatePowermeter() -> Powermeter:
config.get('MQTT_POWERMETER', 'MQTT_USERNAME', fallback=config.get('MQTT_CONFIG', 'MQTT_USERNAME', fallback=None)),
config.get('MQTT_POWERMETER', 'MQTT_PASSWORD', fallback=config.get('MQTT_CONFIG', 'MQTT_PASSWORD', fallback=None))
)
elif config.getboolean('SELECT_POWERMETER', 'USE_DEBUG_READER'):
return DebugReader()
else:
raise Exception("Error: no powermeter defined!")

Expand Down Expand Up @@ -1479,7 +1571,9 @@ def CreateIntermediatePowermeter(dtu: DTU) -> Powermeter:
elif config.getboolean('SELECT_INTERMEDIATE_METER', 'USE_AMIS_READER_INTERMEDIATE'):
return AmisReader(
config.get('INTERMEDIATE_AMIS_READER', 'AMIS_READER_IP_INTERMEDIATE')
)
)
elif config.getboolean('SELECT_INTERMEDIATE_METER', 'USE_DEBUG_READER_INTERMEDIATE'):
return DebugReader()
else:
return dtu

Expand All @@ -1498,6 +1592,10 @@ def CreateDTU() -> DTU:
config.get('OPEN_DTU', 'OPENDTU_USER'),
config.get('OPEN_DTU', 'OPENDTU_PASS')
)
elif config.getboolean('SELECT_DTU', 'USE_DEBUG'):
return DebugDTU(
inverter_count
)
else:
raise Exception("Error: no DTU defined!")

Expand Down
5 changes: 4 additions & 1 deletion HoymilesZeroExport_Config.ini
Original file line number Diff line number Diff line change
Expand Up @@ -19,11 +19,12 @@
# ---------------------------------------------------------------------

[VERSION]
VERSION = 1.97
VERSION = 1.102
[SELECT_DTU]
# --- define your DTU (only one) ---
USE_AHOY = false
USE_OPENDTU = false
USE_DEBUG = false

[SELECT_POWERMETER]
# --- define your Powermeter (only one) ---
Expand All @@ -39,6 +40,7 @@ USE_VZLOGGER = false
USE_SCRIPT = false
USE_AMIS_READER = false
USE_MQTT = false
USE_DEBUG_READER = false

[AHOY_DTU]
# --- defines for AHOY-DTU ---
Expand Down Expand Up @@ -174,6 +176,7 @@ USE_VZLOGGER_INTERMEDIATE = false
USE_SCRIPT_INTERMEDIATE = false
USE_AMIS_READER_INTERMEDIATE = false
USE_MQTT_INTERMEDIATE = false
USE_DEBUG_READER_INTERMEDIATE = false

[INTERMEDIATE_TASMOTA]
# --- defines for Tasmota Smartmeter Modul---
Expand Down