Skip to content

Commit

Permalink
Code review, some documentation updates and optional more descriptive…
Browse files Browse the repository at this point in the history
… product name/enums, fixed extension bit resulting from documentation bug, added diesel/gasoline coefficients, made butane setting only available on bottom-up sensors that support LPG.

Completely un-compiled and untested... I don't have hardware and it seems the velib submodule/repo is not available.
  • Loading branch information
jkhax0r committed Sep 28, 2023
1 parent b656edc commit 4a01ef0
Showing 1 changed file with 52 additions and 37 deletions.
89 changes: 52 additions & 37 deletions src/mopeka.c
Original file line number Diff line number Diff line change
Expand Up @@ -12,14 +12,14 @@
#include "mopeka.h"
#include "task.h"

#define HW_ID_LPG 3 // Pro Check LPG bottom-up
#define HW_ID_P200 4 // Pro-200 top-down
#define HW_ID_H2O 5 // Pro Check H2O bottom-up
#define HW_ID_PPB 8 // PRO+ top-down Boosted BLE sensor
#define HW_ID_PPC 9 // PRO+ top-down Cellular Sensor
#define HW_ID_TDB 0x0A // TD-40 Top-down Boosted BLE sensor
#define HW_ID_TDC 0x0B // TD-40 Top-down Cellular Sensor
#define HW_ID_UNIV 0x0C // Pro Check Universal Sensor
#define HW_ID_PRO 3 // Pro Check LPG bottom-up
#define HW_ID_PRO_200 4 // Pro-200, top-down
#define HW_ID_PRO_H2O 5 // Pro Check H2O, bottom-up
#define HW_ID_PRO_PLUS_BLE 8 // PRO+ bottom-up, Boosted BLE sensor
#define HW_ID_PRO_PLUS_CELL 9 // PRO+ bottom-up, Bluetooth + Cellular Sensor
#define HW_ID_TOPDOWN_BLE 10 // TD-40 or TD-200, Top-down, Boosted BLE sensor
#define HW_ID_TOPDOWN_CELL 11 // TD-40 or TD-200, Top-down, Bluetooth + Cellular Sensor
#define HW_ID_UNIVERSAL 12 // Pro Check Universal Sensor, bottom-up

#define FLUID_TYPE_FRESH_WATER 1
#define FLUID_TYPE_WASTE_WATER 2
Expand Down Expand Up @@ -103,7 +103,8 @@ static int mopeka_init(struct VeItem *root, void *data)
ble_dbus_set_item(root, "Remaining",
veVariantInvalidType(&v, VE_FLOAT), &veUnitm3);

if (hwid != HW_ID_H2O) {
// Add butane slider only for bottom up sensors that might support propane/butane
if (hwid != HW_ID_PRO_H2O && hwid != HW_ID_TOPDOWN_BLE && hwid != HW_ID_TOPDOWN_CELL && hwid != HW_ID_PRO_200) {
ble_dbus_add_settings(root, mopeka_lpg_settings,
array_size(mopeka_lpg_settings));
}
Expand All @@ -129,6 +130,10 @@ static const float mopeka_coefs_lpg[] = {
0.573045, -0.002822, -0.00000535,
};

static const float mopeka_coefs_gasoline[] = {
0.7373417462, -0.001978229885, 0.00000202162,
};

static const float mopeka_coefs_butane[] = {
0.03615, 0.000815,
};
Expand Down Expand Up @@ -159,18 +164,28 @@ static int mopeka_xlate_level(struct VeItem *root, VeVariant *val, uint64_t rv)
temp = veItemValueInt(root, "Temperature");
temp += 40;

// Check for presence of extension bit on certain hardware/firmware -
// it will always be 0 on old firmware/hardware where raw value saturates
// at 16383. When extension bit is set, the raw_value resolution changes
// to 4us with 16384us offet. Thus legacy sensors and firmware still
// have 0 to 16383us range with 1us, and new versions add the range 16384us
// to 81916us with 4us resolution
tank_level_ext = veItemValueInt(root, "TankLevelExtension");
rv += tank_level_ext << 14;
if (tank_level_ext) {
rv = 16384 + rv * 4;
}

switch (hwid) {
case HW_ID_LPG:
case HW_ID_PRO:
scale = mopeka_scale_butane(root, temp);
coefs = mopeka_coefs_lpg;
break;
case HW_ID_H2O:
case HW_ID_PRO_H2O:
coefs = mopeka_coefs_h2o;
break;
case HW_ID_UNIV:
case HW_ID_PRO_PLUS_BLE:
case HW_ID_PRO_PLUS_CELL:
case HW_ID_UNIVERSAL:
switch (fluid_type) {
case FLUID_TYPE_FRESH_WATER:
case FLUID_TYPE_WASTE_WATER:
Expand All @@ -183,23 +198,23 @@ static int mopeka_xlate_level(struct VeItem *root, VeVariant *val, uint64_t rv)
case FLUID_TYPE_LPG:
// printf("Using LPG coefficients for level calculation\n");
scale = mopeka_scale_butane(root, temp);
coefs = mopeka_coefs_lpg;
coefs = mopeka_coefs_lpg;
break;
case FLUID_TYPE_OIL:
case FLUID_TYPE_GASOLINE:
case FLUID_TYPE_DIESEL:
coefs = mopeka_coefs_gasoline;
break;
case FLUID_TYPE_LNG:
case FLUID_TYPE_OIL:
case FLUID_TYPE_HYDRAULIC_OIL:
default:
// printf("No coefficients for fluid type\n");
return -1;
}
break;
case HW_ID_P200:
case HW_ID_PPB:
case HW_ID_PPC:
case HW_ID_TDB:
case HW_ID_TDC:
case HW_ID_PRO_200:
case HW_ID_TOPDOWN_BLE:
case HW_ID_TOPDOWN_CELL:
// printf("Using AIR coefficients for level calculation\n");
coefs = mopeka_coefs_air;
break;
Expand Down Expand Up @@ -312,7 +327,7 @@ static void mopeka_update_level(struct VeItem *root)
empty = veItemValueInt(root, "RawValueEmpty");
full = veItemValueInt(root, "RawValueFull");

if (hwid == HW_ID_PPB || hwid == HW_ID_PPC || hwid == HW_ID_TDB || hwid == HW_ID_TDC || hwid == HW_ID_P200) {
if (hwid == HW_ID_TOPDOWN_BLE || hwid == HW_ID_TOPDOWN_CELL || hwid == HW_ID_PRO_200) {
if (empty < full) {
veItemInvalidate(veItemByUid(root, "Level"));
veItemInvalidate(veItemByUid(root, "Remaining"));
Expand Down Expand Up @@ -365,29 +380,29 @@ int mopeka_handle_mfg(const bdaddr_t *addr, const uint8_t *buf, int len)
hwid = buf[0];

switch (hwid) {
case HW_ID_LPG:
type = "LPG";
case HW_ID_PRO:
type = "Pro";
break;
case HW_ID_H2O:
type = "H2O";
case HW_ID_PRO_H2O:
type = "Pro H2O";
break;
case HW_ID_P200:
type = "Pro200";
case HW_ID_PRO_200:
type = "Pro 200";
break;
case HW_ID_PPB:
type = "PPB";
case HW_ID_PRO_PLUS_BLE:
type = "Pro+ BLE";
break;
case HW_ID_PPC:
type = "PPC";
case HW_ID_PRO_PLUS_CELL:
type = "Pro+ Cell";
break;
case HW_ID_TDB:
type = "TDB";
case HW_ID_TOPDOWN_BLE:
type = "Topdown BLE";
break;
case HW_ID_TDC:
type = "TDC";
case HW_ID_TOPDOWN_CELL:
type = "Topdown Cell";
break;
case HW_ID_UNIV :
type = "Univ";
case HW_ID_UNIVERSAL :
type = "Universal";
break;
default:
return -1;
Expand Down

0 comments on commit 4a01ef0