Skip to content

sa7mon/ups-telegraf

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

22 Commits
 
 
 
 
 
 
 
 

Repository files navigation

Description

Get data from USB-connected UPS into InfluxDB using Telegraf

Transforms upsc output like this:

battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 3133
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.1
battery.voltage.nominal: 12

into InfluxDB Line Protocol like this:

ups battery.charge=100,battery.charge.low=10,battery.charge.warning=20,battery.mfr.date="CPS",battery.runtime=2970,battery.runtime.low=300,battery.type="PbAcid",battery.voltage=13.1,battery.voltage.nominal=12

Usage

Edit the script string_measurements variable to reflect your setup. Specifically, add any additional measurement names that your UPS provides to the string_measurements array (in sorted order) so they will be included in the output.

To see all the measurements your UPS provides, run this:

upsc YOUR_UPS_NAME_HERE 2>/dev/null | awk -F':' 'BEGIN {print "string_measurements=["} {print "\"" $1 "\", "} END {print "]"}' |tr -d '\n'

Call the script from telegraf.conf like this

[[inputs.exec]]

   commands = ["python /path/to/getUpsData.py <YOUR_UPS_NAME_HERE>"]
   timeout = "5s"
   data_format = "influx"

Compatibility

Tested on:

  • Cyberpower CP1000AVRLCDa
  • CyberPower SL700U (CyberPowerSL700U.py)
  • Dell UPS 1000T/1920T/1920R HV (DellBadge-Eaton5PX.py)
  • MGE Pulsar 2200

If you're using this with a different UPS, please let me know so I can add it to the list

Contributors

Thanks to the following for helping improve this repo.

  • @openincident
  • @mattster98
  • @Graffics

About

Get data from USB-connected UPS with Telegraf

Topics

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages