DAQ software for a CAEN V1730 digitizer with waveform recording firmware. Software assumes connection through a V1718 VME-USB Bridge
This software is based on the CAEN wavedump example program
For instructions on setting up a virtual machine, see here.
Download the repository using this command:
git clone https://github.com/samdejong86/CAEN-v1730-DAQ.git
Requires the CAEN Digitizer libraries. Install in this order:
If the tar files containing the libraries are placed in the drivers directory, run source CAEN_driver_install.sh as root in that directory to automatically install the libraries. NOTE JUNE 2023: Due to changes in the CAEN libraries, this automatic script no longer works. Manual installation is required instead.
Note: Updates to your system may break the CAEN libraries. If the DAQ software stops working, try reinstalling the VME and USB libraries.
Requires ROOT (available here). You may need these libraries:
- libX11-devel.x86_64
- libXpm-devel.x86_64
- libXft-devel.x86_64
- libXext-devel.x86_64
ROOT can also be installed with
sudo yum install -y epel-release && sudo yum install root
-
If you are getting an error about 'shape.h', try:
ln -s /usr/include/X11/extensions/shapeproto.h /usr/include/X11/extensions/shape.h
Once these are installed, use make to build the software.
Run sudo make install
to install the software system wide.
usage: CAENdaq [-h] [-v] [-x XMLFILE] [--xmlout XMLFILE] [-q] [w0] [w1]
[w2] [w3] ... [-o FILE] [-r RECLEN] [-n NUM] [-d DURATION]
[--posttrigger VAL] [--polarity0 POLARITY] ...
[--threshold0 THRESHOLD] ... [--trslope0 POLARITY] ...
Reads waveforms from a CAEN V1730 digitizer.
Mandatory arguments to long options are mandatory for short options too.
-h, --help Show this help message and exit
-v, --verbose Prints verbose setup information
-x XMLFILE, --xml XMLFILE Use settings in XMLFILE. This
overrides other command line settings
--xmlout XMLFILE Save settings to xml file
-q, --quit Used with --xmlout. Quits program after
saving settings
--tutorial Open the tutorial in a web browser
The following options can also be set using an XML file, with the
long options as the XML tags:
-w <CH>, --ch <CH> Record the waveform on CH
Valid options are 0-7
-o FILE, --outfile FILE Save waveform to FILE
-n NUM, --saveInterval After NUM events, save a temporary file.
At the end of the run, these will be merged
-r RECLEN, --reclen RECLEN Set number of samples recorded to RECLEN
-d DURATION, --duration DURATION
Duration of the run. If an integer is
specified, that many events are recorded.
If a time is specified in HH:MM:SS format
the daq will run for that long. Acquisition
starts automatically.
If not used, daq must be started manually
--polarity<CH> POLARITY Set pulse polarity of channel CH
Valid options are POSITIVE or NEGATIVE
--threshold<CH> THRESHOLD Set the trigger threshold of channel CH
in ADC counts
--trslope<CH> POLARITY Trigger slope. Can be POSITIVE or NEGATIVE
--posttrigger VAL Set the post trigger
--triggermode MODE Set the trigger mode. Valid options are AND
and OR.
--coincidencewindow WINDOW Set the length of the coincidence window, in
multiples of 8ns. Maximum value is 15.
To display the DAQ command line parameters, run
CAENdaq -h
There are two ways to set the digitizer parameters: through the command line, or via an XML file. A simple run example is:
CAENdaq --outfile FILE.root --duration 1000 --ch 0 --polarity0 POSITIVE --threshold0 100 --trslope0 POSITIVE
These same parameters can be set via an xml file:
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<polarity0>
POSITIVE
</polarity0>
<threshold0>
100
</threshold0>
<trslope0>
POSITIVE
</trslope0>
</Active>
</xml>
which can be run with this command:
CAENdaq -x XMLFILE.xml
assuming the xml file is named XMLFILE.xml. Any other command line arguments which set digitizer settings will be ignored if an xml file is specified.
Note that the xml tags are the same as the command line options, eg:
--outfile FILE.root
on the command line is equivalent to
<outfile>
FILE.root
</outfile>
in the xml file.
XML File Generation
The xml files used by the DAQ software can be created using a text editior, or by using the --xmlout
command line argument. This argument will take the digitizer settings set at the command line and save them as an xml file:
CAENdaq --outfile myfile.root --duration 3000 --ch 4 --polarity4 NEGATIVE --threshold4 100 --trslope4 NEGATIVE --xmlout mySettings.xml
will produce mySettings.xml, which will look like this:
<xml>
<Active>
<outfile>
myfile.root
</outfile>
<duration>
3000
</duration>
<ch4>
1
</ch4>
<polarity4>
NEGATIVE
</polarity4>
<threshold4>
100
</threshold4>
<trslope4>
NEGATIVE
</trslope4>
</Active>
</xml>
Adding -q
on the command line will quit the DAQ after generating the xml file.
There are two ways of using the duration option.
Number of events
If an integer is used as the parameter, that many events will be recorded. Example command:
CAENdaq --duration 1000
or in XML:
<duration>
1000
</duration>
will collect 1000 events before closing
Timed acquisition
If a time is specified in HH:MM:SS, events will be collected for that amount of time. Example command:
CAENdaq --duration 01:30:00
or in XML:
<duration>
01:30:00
</duration>
will collect events for 90 minutes before closing
For a positive pulse, polarity should be set to POSITIVE, and for a negative pulse, it should be set to NEGATIVE. trslope may be set to POSITIVE or NEGATIVE depending on where the desired trigger point is. A general rule of thumb is that the trigger polarity and the pulse polarity should be the same.
Positive pulse with positive trigger
Trigger will occur when the signal rises above 100. The red line is the trigger point.
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --polarity0 POSITIVE --threshold0 100 --trslope0 POSITIVE
Example xml file (xml/PositivePulsePositiveTrigger.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<polarity0>
POSITIVE
</polarity0>
<threshold0>
100
</threshold0>
<trslope0>
POSITIVE
</trslope0>
</Active>
</xml>
Positive pulse with negative trigger
Trigger will occur when the signal falls below 100. The red line is the trigger point.
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --polarity0 POSITIVE --threshold0 100 --trslope0 NEGATIVE
Example xml file (xml/PositivePulseNegativeTrigger.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
<ch0>
1
</ch0>
<polarity0>
POSITIVE
</polarity0>
<threshold0>
100
</threshold0>
<trslope0>
NEGATIVE
</trslope0>
</Active>
</xml>
Negative pulse with positive trigger
Trigger will occur when the signal rises above 100. The red line is the trigger point.
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --polarity0 NEGATIVE --threshold0 100 --trslope0 POSITIVE
Example xml file xml/NegativePulsePositiveTrigger.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<polarity0>
NEGATIVE
</polarity0>
<threshold0>
100
</threshold0>
<trslope0>
POSITIVE
</trslope0>
</Active>
</xml>
Negative pulse with negative trigger
Trigger will occur when the signal falls below 100. The red line is the trigger point.
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --polarity0 NEGATIVE --threshold0 100 --trslope0 NEGATIVE
Example xml file (xml/NegativePulseNegativeTrigger.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<polarity0>
NEGATIVE
</polarity0>
<threshold0>
100
</threshold0>
<trslope0>
NEGATIVE
</trslope0>
</Active>
</xml>
The record length setting sets the number of samples in a waveform. A higher number will create a longer waveform.
Low record length
In this example the record length is set to 512 samples.
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --reclen 512 --threshold0 100
Example xml file (xml/RecordLength_512.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<reclen>
512
</reclen>
<threshold0>
100
</threshold0>
</Active>
</xml>
Medium record length
In this example the record length is set to 1024 samples (the default).
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --reclen 1024 --threshold0 100
Example xml file (xml/RecordLength_1024.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<reclen>
1024
</reclen>
<threshold0>
100
</threshold0>
</Active>
</xml>
High record length
In this example the record length is set to 2048 samples.
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --reclen 2048 --threshold0 100
Example xml file (xml/RecordLength_2048.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<reclen>
2048
</reclen>
<threshold0>
100
</threshold0>
</Active>
</xml>
The post trigger setting sets how much of the waveform will be after the trigger occurs. valid settings are 0 to 100. Setting this to 50 is a good rule of thumb.
Post trigger of 0
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --posttrigger 0 --threshold0 100
Example xml file (xml/PostTrigger_0.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<posttrigger>
0
</posttrigger>
<threshold0>
100
</threshold0>
</Active>
</xml>
Post trigger of 25
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --posttrigger 25 --threshold0 100
Example xml file (xml/PostTrigger_25.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<posttrigger>
25
</posttrigger>
<threshold0>
100
</threshold0>
</Active>
</xml>
Post trigger of 50 (the default setting)
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --posttrigger 50 --threshold0 100
Example xml file (xml/PostTrigger_50.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<posttrigger>
50
</posttrigger>
<threshold0>
100
</threshold0>
</Active>
</xml>
Post trigger of 75
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --posttrigger 75 --threshold0 100
Example xml file (xml/PostTrigger_75.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<posttrigger>
75
</posttrigger>
<threshold0>
100
</threshold0>
</Active>
</xml>
Post trigger of 100
Example command line arguments:
CAENdaq -o FILE.root -d 1000 --ch 0 --posttrigger 100 --threshold0 100
Example xml file (xml/PostTrigger_100.xml)
<xml>
<Active>
<duration>
1000
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<posttrigger>
100
</posttrigger>
<threshold0>
100
</threshold0>
</Active>
</xml>
If mutiple channels have threshold<CH>
set, the triggers will be combined. There are two possibe modes for combining multiple trigger channels: AND and OR. The trigger mode is set with the triggermode
setting
Combining triggers with AND
Triggering will only occur when the trigger conditions are satisfied on all channels with threshold<CH>
set. For example:
CAENdaq -o FILE.root -d1000 --ch 0 --ch 1 --polarity0 POSITIVE --polarity1 POSITIVE --threshold0 100 --threshold1 100 --trslope0 POSITIVE --trslope1 POSITIVE --triggermode AND
Example xml file (xml/ANDtrigger.xml)
<xml>
<Active>
<duration>
00:01:00
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<polarity0>
POSITIVE
</polarity0>
<threshold0>
100
</threshold0>
<trslope0>
POSITIVE
</trslope0>
<ch1>
1
</ch1>
<polarity1>
POSITIVE
</polarity1>
<threshold1>
100
</threshold1>
<trslope1>
POSITIVE
</trslope1>
<triggermode>
AND
</triggermode>
</Active>
</xml>
This will trigger when both channel 0 and channel 1 go above 100 ADC counts.
Note: AND is the default setting for the triggermode
setting
The coincidencewindow
can be used to set the length of the window where the coincident triggers must occur, in units of 8ns. It takes an integer less than or equal to 15. For example:
CAENdaq --triggermode AND --coincidencewindow 12
or in XML:
<triggermode>
AND
</triggermode>
<coincidencewindow>
12
</coincidencewindow>
will require a trigger on each trigger enabled channel within 96ns. The default value for this parameter is 10, or 80ns.
Combining triggers with OR
Triggering will occur when the trigger conditions are satisfied on any channel. For example:
CAENdaq -o FILE.root -d1000 --ch 0 --ch 2 --polarity0 POSITIVE --polarity2 POSITIVE --threshold0 100 --threshold2 100 --trslope0 POSITIVE --trslope2 POSITIVE --triggermode OR
Example xml file (xml/ORtrigger.xml)
<xml>
<Active>
<duration>
00:01:00
</duration>
<outfile>
FILE.root
</outfile>
<ch0>
1
</ch0>
<polarity0>
POSITIVE
</polarity0>
<threshold0>
100
</threshold0>
<trslope0>
POSITIVE
</trslope0>
<ch2>
1
</ch2>
<polarity2>
POSITIVE
</polarity2>
<threshold2>
100
</threshold2>
<trslope2>
POSITIVE
</trslope2>
<triggermode>
OR
</triggermode>
</Active>
</xml>
will trigger when either of channel 0 or channel 2 go abouve 100 ADC counts
The digitizer channels are paired together: 0&1, 2&3, 4&5, 6&7. If the triggermode is set to OR and triggering is enabled on both channels of a pair, the even channel is ignored and only the odd channel has a trigger applied. If OR triggering on multiple channels is required, the trigger must be applied on channels from seperate pairs. This is due to a limitation on the digitizer firmware.
For example:
CAENdaq -o FILE.root -d1000 --ch 0 --ch 1 --threshold0 100 --threshold1 100 --triggermode OR
will only apply the trigger to channel 1, but
CAENdaq -o FILE.root -d1000 --ch 0 --ch 2 --threshold0 100 --threshold2 100 --triggermode OR
will apply the trigger correctly to both channel 0 and channel 2
When the program starts, it will create a temporary directory called FILE_<timestamp>
, where <timestamp>
is the unix time when the program started. Temporary root files containing <saveInterval>
(set by the saveInterval
parameter at the command line or in an xml file) events will be saved here.
When the program exits safely these files will be merged together, with the resulting file moved to the working directory. The temporary directory will then be removed.
If the program crashes, the temporary files will not be removed, so most of the data from the run can be recovered by looking in this directory.
There is a ROOT script included with the repository called draw.C
. This script can be used to display a waveform from a ROOT file created by the DAQ.
Usage:
root[0] .x draw.C("FILE.root", channel, event)
where channel and event are integers for the channel number and event number.
This script can also be used as an example showing how to load waveforms, for use in an analysis.
src/
source files
include/
header files
xml/*.xml
Some example settings files
icon/CAEN.png
Icon for the notification
Makefile
for building the software
draw.C
A root script for drawing waveforms
drivers/CAEN\_driver\_install.sh
A script for installing the CAEN libraries. The tar files containing the libraries must be located in the same directory as this script
img/*
Images used in the tutorial section of this document
This software used code in CAEN's wavedump example, modified to be in an object oriented framework.