cell-monitor

Battery cell monitor and balancer based on the AVR ATTiny85 MCU.

  • reads cell voltage and temperature
  • switches balancing FET
  • communicates with a host controller via isolated serial
  • low power consumption (<1mA when idle, ~2mA while active)

A cell monitor is intended to monitor a single cell as part of a larger series pack. The cell monitor is powered directly from the cell it monitors and works with any chemistry where the voltage remains within 1.8V-5.5V (i.e. lithium-ion, LiFePO4).

Build

Dependencies:

make
make fuse
make flash

Wiring

Cell monitors are wired in a daisy chain with the TX from the host controller connected to the RX of cell monitor 1, the TX of cell monitor 1 connected to the RX of cell monitor 2, etc. The TX of cell monitor N is connected to the RX of the host controller.

+-----------+
| HOST   RX | <------------------------------------------+
|        TX | >---+    +--->---+    +--->  ...  >---+    |
+-----------+     |    |       |    |               |    |
                  |    |       |    |               |    |
                +--------+   +--------+           +--------+
                | RX  TX |   | RX  TX |    ...    | RX  TX |
                |    1   |   |    2   |    ...    |    N   |
                +--------+   +--------+    ...    +--------+

Cell monitors are addressed by their position in the daisy chain.

Serial protocol

The host controller initiates all communication with the network of cell monitors and does so at 9600 baud. The host controller sends a request packet which is forwarded through the daisy chain to an addressed cell monitor. The addressed cell monitor will reply with a similar response packet which will be forwarded through the remaining chain and eventually read by the host controller.

Packet structure

Communication consists of 5 byte packets with the following structure:

Byte 7 6 5 4 3 2 1 0
1 ADDR6 ADDR5 ADDR4 ADDR3 ADDR2 ADDR1 ADDR0 REQ
2 REG6 REG5 REG4 REG3 REG2 REG1 REG0 WRITE
3 VAL15 VAL14 VAL13 VAL12 VAL11 VAL10 VAL9 VAL8
4 VAL7 VAL6 VAL5 VAL4 VAL3 VAL2 VAL1 VAL0
5 CRC7 CRC6 CRC5 CRC4 CRC3 CRC2 CRC1 CRC0
  • ADDR6-0 - cell monitor address
  • REQ - 1 if packet is a request, 0 if packet is a response
  • REG6-0 - register (described below)
  • WRITE - 1 if packet is a write command, 0 if packet is a read command
  • VAL15-0 - value
  • CRC7-0 - CRC8 of prior 4 bytes

Registers

  • 0x1 - cell address (1 byte, unsigned)
  • 0x2 - reference voltage (2 bytes, unsigned)
  • 0x3 - cell voltage (2 bytes, unsigned)
  • 0x4 - celsius temperature (2 bytes, signed)
  • 0x5 - balance (1 if balancing, 0 otherwise)

Example

Reading the voltage from cell 1

Request:

Byte Value
1 00000011
2 00000110
3 00000000
4 00000000
5 11010110
  • ADDR = 1
  • REQ bit set to 1
  • REG = 3
  • WRITE bit set to 0
  • VAL is not applicable for read request
  • CRC = crc8(50724864)

The following response will be received:

Byte Value
1 00000010
2 00000110
3 00001100
4 11100100
5 01110111
  • ADDR = 1
  • REQ bit set to 0
  • REG = 3
  • WRITE bit set to 0
  • VAL is the returned voltage (3300mV in this example)
  • CRC = crc8(33950948)

Address assignment

A cell monitor has an undefined address when it is initially powered on. The host controller needs to initiate an address assignment request (which has slightly different semantics than other value requests):

Byte Value
1 00000001
2 00000011
3 00000000
4 00000001
5 00110011
  • ADDR = 0 (broadcast to all cell monitors)
  • REQ bit set to 1
  • REG = 1
  • WRITE bit set to 1
  • VAL = first cell address
  • CRC = crc8(16973825)

The first cell monitor will receive the request and set its address to the value in the VAL field. Instead of sending a response it will increment the VAL field and forward the request onward. Eventually the host controller will receive the same request packet (with an incremented VAL). The host controller should assert that VAL equals 1 more than the number of cell monitors in the network.