Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[Mellanox] Update SDK/FW to version 4.5.3186/2010_3186 #12542

Conversation

dprital
Copy link
Collaborator

@dprital dprital commented Oct 28, 2022

Signed-off-by: dprital drorp@nvidia.com

Why I did it

Update SDK/FW version - 4.5.3186/2010_3186 in order to have the following changes:

New functionality:

  • Added support for 6.5W (Class 8) in ports 49-50, 53-54, 57-58, and 61-62 on SN4600 system

Fix the following issues:

  • On very rare occasion (~1/100K), during I2C transaction with MMS1V50-WM and MMS1V90-WR modules on SN4700 system, the module may send unexpected stop which violate the I2C specification, possibly affecting the link up flow
  • When running 1GbE speeds on SN4600 system, the port remained active while peer side was closed
  • While toggling the cable with ‘sfputil lpmode on/off’, error msg like “ERR pmon#xcvrd: Receive PMPE error event on module 1: status {X} error type {y}” could be received
  • When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted
  • When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU
  • While moving from lossless to lossy mode while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized
  • SDK Dump missing column headers in some GC tables may result in difficulty understanding the dump
  • SLL configuration is missing in SDK dump
  • SDK debug dump shows "Unknown" Counter in RFC3635 Counter Group
  • SDK debug dump shows "Unknown" Counter in the Traffic Class Counter Group
  • If TTL_CMD_COPY is used in Encap direction for a packet with no TTL, then the value passed in the ttl data structure will be used if non-zero (default 255 if zero)
  • PCI calibration changes from a static to a dynamic mechanism
  • Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event
  • SDK returned error when FEC mode is set on twisted pair, when FEC was set to None

How I did it

Update pointer for the SDK/FW

How to verify it

Run regression tests

Which release branch to backport (provide reason below if selected)

  • 201811
  • 201911
  • 202006
  • 202012
  • 202106
  • 202111
  • 202205

Description for the changelog

Ensure to add label/tag for the feature raised. example - PR#2174 under sonic-utilities repo. where, Generic Config and Update feature has been labelled as GCU.

Link to config_db schema for YANG module changes

A picture of a cute animal (not mandatory but encouraged)

Signed-off-by: dprital <drorp@nvidia.com>
@liat-grozovik liat-grozovik marked this pull request as ready for review October 30, 2022 07:30
@liat-grozovik liat-grozovik merged commit 917ad1f into sonic-net:master Oct 30, 2022
@dprital dprital deleted the update_sdk_fw_ver_to_4_5_3186_2010_3186_master branch October 31, 2022 16:58
yxieca pushed a commit that referenced this pull request Nov 10, 2022
- Why I did it
Update SDK/FW version - 4.5.3186/2010_3186 in order to have the following changes:

New functionality:
1. Added support for 6.5W (Class 8) in ports 49-50, 53-54, 57-58, and 61-62 on SN4600 system

Fix the following issues:
1. On very rare occasion (~1/100K), during I2C transaction with MMS1V50-WM and MMS1V90-WR modules on SN4700 system, the module may send unexpected stop which violate the I2C specification, possibly affecting the link up flow
2. When running 1GbE speeds on SN4600 system, the port remained active while peer side was closed
3. While toggling the cable with ‘sfputil lpmode on/off’, error msg like “ERR pmon#xcvrd: Receive PMPE error event on module 1: status {X} error type {y}” could be received
4. When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted
5. When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU
6. While moving from lossless to lossy mode while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized
7. SLL configuration is missing in SDK dump
8. If TTL_CMD_COPY is used in Encap direction for a packet with no TTL, then the value passed in the ttl data structure will be used if non-zero (default 255 if zero)
9. PCI calibration changes from a static to a dynamic mechanism
10. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event
11. SDK returned error when FEC mode is set on twisted pair, when FEC was set to None

- How I did it
Update pointer for the SDK/FW

- How to verify it
Run regression tests

Signed-off-by: dprital <drorp@nvidia.com>
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment