Notifications
You must be signed in to change notification settings - Fork 32
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Charge Log has incorrect data #85
Comments
I can currently not reproduce the behavior. wbec calculates energyI (=Energy since installation) of ChargeEnd - energyI of ChargeStart On the other hand, it can be seen, that the endTime of one entry is often the startTime of the next entry. |
It’s got weirder over the past days … going backwards - and the last entry looks like it could be right, perhaps this happens under strange start condition. I’ll delete the log as you suggest and update. 04.07.2023 | 05:43 09.07.2023 | 19:16 0.201 133:33 1 |
Sorry, still doing it... Start Ende Geladene Note that the car is not used a lot, and plugged in all the time |
Kannst du bitte mal prüfen, ob wbec zu diesen Zeitpunkten einen Reset hatte? |
{"wbec":{"version":"v1.4.9","bldDate":"May 28 2023 21:45:14","timeNow":"00:39:53"},"box":[{"busId":1,"version":"108","chgStat":4,"currL1":0,"currL2":0,"currL3":0,"pcbTemp":275,"voltL1":242,"voltL2":241,"voltL3":240,"extLock":1,"power":0,"energyP":7.411,"energyI":102.508,"energyC":0,"currMax":16,"currMin":6,"logStr":"00.779.2909/01 022900 2147 HD_EnergyControl","wdTmOut":60000,"standby":4,"remLock":1,"currLim":0,"currFs":0,"lmReq":0,"lmLim":255,"resCode":"0"}],"modbus":{"state":{"lastTm":3590614516,"millis":3590614831}},"rfid":{"enabled":false,"release":false,"lastId":""},"pv":{"mode":0,"watt":0},"wifi":{"mac":"78:21:84:A6:EA:28","rssi":-73,"signal":54,"channel":11}} |
Ladeübersicht Start Ende Geladene |
Current time 00:44 |
Ich habe hier ein vergleichbares Problem seit dem Update auf die V0.4.9 (vorher 0.4.5) an einer Heidelberg Energy Control; derzeit noch ohne PV-Anlage. In der JSON-Datei steht dann u.A: Nach einen Reset der Wallbox (Sicherung aus und wieder ein) ist für ein paar Minuten alles in Ordnung: Wenn ich dann einen Reset des wbec-Controllers durchführe, stehen nur noch Null-Werte in der JSON-Datei. Ich hänge hier mal drei JSON-Dateien an:
Hoffentlich kannst Du mit diesen Information die Fehlerursache eingrenzen; gerne liefere ich weitere Daten nach! Gruß aus dem Tecklenburger Land OK.json.txt Nachtrag: |
@kalwados: Du hast den Standby aktiviert, oder? |
@salamander-in-steinachtal |
Ja, habe Standby kurz nach meiner Meldung wieder deaktiviert, läuft bislang ohne Probleme.--Diese Nachricht wurde von meinem Android Mobiltelefon mit GMX Mail gesendet.Am 26.08.23, 17:37 schrieb steff393 ***@***.***>:
@kalwados: Du hast den Standby aktiviert, oder? In der nächsten Version kommt eine Änderung, die damit besser umgehen kann. Aktuell würde ich ihn eher deaktivieren.
—Reply to this email directly, view it on GitHub, or unsubscribe.You are receiving this because you were mentioned.Message ID: ***@***.***>
|
{"line":[{"timestamp":1689452095,"duration":213575,"energy":4294864788,"user":0,"box":0},{"timestamp":1689669334,"duration":1424,"energy":0,"user":0,"box":0},{"timestamp":1689701505,"duration":169205,"energy":4294864788,"user":0,"box":0},{"timestamp":1689870749,"duration":183411,"energy":4294864788,"user":0,"box":0},{"timestamp":1690055015,"duration":208175,"energy":4294864788,"user":0,"box":0},{"timestamp":1690263216,"duration":15121,"energy":4294860175,"user":0,"box":0},{"timestamp":1690278349,"duration":271,"energy":4294860175,"user":0,"box":0},{"timestamp":1690278833,"duration":874,"energy":0,"user":0,"box":0},{"timestamp":1690908198,"duration":20846,"energy":4294860175,"user":0,"box":0},{"timestamp":1690929055,"duration":63001,"energy":5898,"user":0,"box":0}]} |
Danke, ich kann's mittlerweile nachstellen. Wird in der nächsten Version korrigiert! |
Genius - many thanks! |
The highly useful charge log (many thanks), is returning an odd and constant value of 4294864.989, the charge times are absolutely correct.
{"wbec":{"version":"v1.4.9","bldDate":"May 28 2023 21:45:14","timeNow":"10:57:23"},"box":[{"busId":1,"version":"108","chgStat":4,"currL1":0,"currL2":0,"currL3":0,"pcbTemp":268,"voltL1":236,"voltL2":240,"voltL3":240,"extLock":1,"power":0,"energyP":7.21,"energyI":102.307,"energyC":0,"currMax":16,"currMin":6,"logStr":"00.779.2909/01 022900 2147 HD_EnergyControl","wdTmOut":60000,"standby":4,"remLock":1,"currLim":0,"currFs":0,"lmReq":0,"lmLim":255,"resCode":"0"}],"modbus":{"state":{"lastTm":2245270202,"millis":2245272613}},"rfid":{"enabled":false,"release":false,"lastId":""},"pv":{"mode":0,"watt":0},"wifi":{"mac":"78:21:84:A6:EA:28","rssi":-64,"signal":72,"channel":11}}
web.html --> Energiezähler 102.307 kWh (Correct)
log.html --> (Incorrect)
Ladeübersicht Start Ende Geladene kWh Ladedauer hh:mm Wallbox
04.07.2023 | 05:43 05.07.2023 | 11:03 0.000 29:20 1
03.07.2023 | 22:05 04.07.2023 | 05:42 4294864.989 7:37 1
03.07.2023 | 06:09 03.07.2023 | 22:05 4294864.989 15:55 1
03.07.2023 | 00:33 03.07.2023 | 06:09 4294864.989 5:35 1
02.07.2023 | 13:18 03.07.2023 | 00:31 4294871.249 11:13 1
02.07.2023 | 08:10 02.07.2023 | 13:17 4294872.199 5:07 1
14.06.2023 | 07:06 14.06.2023 | 11:01 0.000 3:54 1
12.06.2023 | 12:20 14.06.2023 | 07:06 4294872.199 42:46 1
12.06.2023 | 10:25 12.06.2023 | 12:15 4294872.199 1:49 1
11.06.2023 | 12:40 12.06.2023 | 10:20 4294872.199 21:39 1
The text was updated successfully, but these errors were encountered: