Fix required double ArrowDown
requirement
#1281
Conversation
If the `activeOptionIndex` is set to `null`, then we default to the very first non-disabled option. This data is _not_ stored in state because if you as the user go to a specific option, then start searching then we will maintain the active option. This means that we have to **update** the `activeOptionIndex` when options are moving around. While making the first option the active one, we can't store that in state directly otherwise the very first option becomes the active one. If we then inject combobox options _before_ the current one then all of a sudden your active option would jump around a bit. We don't want this jumping to happen, we want the very first option to be the one that's active no matter which option it is. Since this is not stored in state, our keydown handler was a bit borked. Internally it thinks we are still at `activeOptionIndex === null` therefore pressing arrow down would move us to `activeOptionIndex === 0`. To go to the second option, we can press down again which would move us to `activeOptionIndex === 1`. The only issue is that visually we were already at `0`. This fixes that by making sure that if we have `activeOptionIndex === null` that we fallback to the very first non disabled option _before_ we execute the `goToOption()` code. ### Before: **Open combobox**, `activeOptionIndex === null` | Combobox | | ----------------------- | | **Option A** _(active)_ | | Option B | | Option C | **Arrow Down**, `activeOptionIndex === 0` | Combobox | | ----------------------- | | **Option A** _(active)_ | | Option B | | Option C | **Arrow Down**, `activeOptionIndex === 1` | Combobox | | ----------------------- | | Option A | | **Option B** _(active)_ | | Option C | ### After: **Open combobox**, `activeOptionIndex === null` | Combobox | | ----------------------- | | **Option A** _(active)_ | | Option B | | Option C | **Arrow Down**, `activeOptionIndex === 1` | Combobox | | ----------------------- | | Option A | | **Option B** _(active)_ | | Option C |
This pull request is being automatically deployed with Vercel (learn more). headlessui-vue – ./packages/playground-vue🔍 Inspect: https://vercel.com/tailwindlabs/headlessui-vue/HSaDAzuFg1NdKnXWT254WCYc9PVG headlessui-react – ./packages/playground-react🔍 Inspect: https://vercel.com/tailwindlabs/headlessui-react/HfRFpXFFSYYSzu8TEGoCeFJRhifa |
Seems to be working! Awesome, thanks @RobinMalfait for the quick fix! 🙌 🙌 🙌 |
Hi @RobinMalfait, thanks for the fix, but it's seems that it's still not working when |
I have the same problem, but my English is not good. So I hope you create an article about this issue. Thank you ! |
If the
activeOptionIndex
is set tonull
, then we default to the very first non-disabled option. This data is not stored in state because if you as the user go to a specific option, then start searching then we will maintain the active option. This means that we have to update theactiveOptionIndex
when options are moving around.While making the first option the active one, we can't store that in state directly otherwise the very first option becomes the active one. If we then inject combobox options before the current one then all of a sudden your active option would jump around a bit.
We don't want this jumping to happen, we want the very first option to be the one that's active no matter which option it is.
Since this is not stored in state, our keydown handler was a bit borked.
Internally it thinks we are still at
activeOptionIndex === null
therefore pressing arrow down would move us toactiveOptionIndex === 0
. To go to the second option, we can press down again which would move us toactiveOptionIndex === 1
. The only issue is that visually we were already at0
.This fixes that by making sure that if we have
activeOptionIndex === null
that we fallback to the very first non disabled option before we execute thegoToOption()
code.Before (3 steps):
Open combobox,
activeOptionIndex === null
Arrow Down,
activeOptionIndex === 0
! Uh ohArrow Down,
activeOptionIndex === 1
After (2 steps):
Open combobox,
activeOptionIndex === null
Arrow Down,
activeOptionIndex === 1