Energy Harvesting Monitor V1.4
Getting Started
Have a look at the README to get started with the release files.
Important information when upgrading from an earlier version
None
Updates
- Specified all relevant component values
- Added output terminal for switched VOUT
- Changed buffer op-amps to max9620 (unity gain stability up to capacitive load of 400pF)
Fixes
- Removed termination cap from buffer outputs
- Added voltage divider to input of input buffer
- Added 0.1uF decoupling cap to buffer rails
- Added resistor to base of high-side switch
License
This project and all original material included with it are released under CC BY-SA 3.0