Expand Up @@ -36,82 +36,136 @@ The **Storage Dashboard** pool widgets also show the status of each of your pool

{{< trueimage src="/images/SCALE/Storage/StoragePoolWidgetsDegradedState.png" alt="Storage Pool Widgets in Degraded State" id="Storage Pool Widgets in Degraded State" >}}

From the main Dashboard, you can click the <i class="fa fa-database" aria-hidden="true" title="Pool Status"></i> on either the **Pool** or **Storage** widget to go to the **Storage Dashboard** screen, or you can click **Storage** on the main navigation menu to open the **Storage Dashboard** and locate the pool in the degraded state.
From the main Dashboard, you can click the <i class="fa fa-database" aria-hidden="true" title="Pool Status"></i> on either the **Pool** or **Storage** widget or you can click **Storage** on the main navigation menu to open the **Storage Dashboard** screen and locate the pool in the degraded state.

{{< expand "My disk is faulted. Should I replace it?" "v" >}}
If a disk shows a faulted state, TrueNAS has detected an issue with that disk and you should replace it.
{{< /expand >}}

To replace a failed disk:
{{< expand "Can I use a disk that is failing but still active?" "v" >}}
There are situations where you can leave a disk that has not completely failed online to provide additional redundancy during the replacement procedure.
{{< hint type=important >}}
We do not recommend leaving failed disks online unless you know the exact condition of the failing disk.
{{< /hint >}}
Attempting to replace a heavily degraded disk without off-lining it significantly slows down the replacement process.
{{< /expand >}}

1. Locate the failed drive.
To replace a disk in a pool without a hot spare available:

a. Go to the **Storage Dashboard** and click **Manage Devices** on the **Topology** widget for the degraded pool to open the **Devices** screen for that pool.
1. [Take the disk offline](#taking-a-failed-disk-offline).
2. [Replace the disk](#replacing-a-failed-disk).
3. Refresh the screen.

b. Click anywhere on the VDEV to expand it and look for the drive with the Offline status.
To replace a disk in a pool with a hot spare:

2. Take the disk offline.
1. [Take the disk offline](#taking-a-failed-disk-offline).
2. [Detach the failed disk](#detaching-a-failed-disk) to promote the hot spare.
3. Refresh the screen.
4. [Recreate the hot spare VDEV](#recreating-the-hot-spare).

{{< trueimage src="/images/SCALE/Storage/DevicesDiskWidgets.png" alt="Devices Disk Widgets" id="Devices Disk Widgets" >}}
## Taking a Failed Disk Offline

Click **Offline** on the **ZFS Info** widget to take the disk offline. The button toggles to **Online**.
We recommend users off-line a disk before starting the physical disk replacement.
Off-lining a disk removes the device from the pool and can prevent swap issues.
To offline a disk:

3. Pull the disk from your system and replace it with a disk of at least the same or greater capacity as the failed disk.
Go to the **Storage Dashboard** and click **Manage Devices** on the **Topology** widget for the degraded pool to open the **Devices** screen for that pool.
Click <span class="iconify" data-icon="mdi:keyboard-arrow-right"></span> next to the VDEV to expand it, then look for the disk with the **REMOVED** status.

{{< trueimage src="/images/SCALE/Storage/ReplaceDiskAndOnline.png" alt="Replace and Online a Disk" id="Replace and Online a Disk" >}}
{{< trueimage src="/images/SCALE/Storage/DevicesDiskDegraded.png" alt="Devices Disk Failed" id="Devices Disk Failed" >}}

a. Click **Replace** on the **Disk Info** widget on the **Devices** screen for the disk you off-lined.
Click on the failed disk, then click **Offline** in the **ZFS Info** widget to take the disk offline.
The disk status changes to **OFFLINE**.

b. Select the new drive from the **Member Disk** dropdown list on the **Replacing disk *diskname*** dialog.
{{< expand "The offline failed?" "v" >}}
If the off-line operation fails with a **Disk offline failed - no valid replicas** message, go to **Storage Dashboard** and click **Scrub** on the **ZFS Health** widget for the pool with the degraded disk. The **Scrub Pool** confirmation dialog opens. Select **Confirm** and then click **Start Scrub**.

{{< trueimage src="/images/SCALE/Storage/StorageZFSHealthScrub.png" alt="Storage ZFS Health Scrub Pool" id="Storage ZFS Health Scrub Pool" >}}

When the scrub operation finishes, return to the **Devices** screen, expand the VDEV, then click the disk, and try to off-line it again.
{{< /expand >}}

## Replacing a Failed Disk

If you are replacing the failed disk you took offline and removed, insert the replacement disk now.
The new disk must have the same or greater capacity as the failed disk.
If replacing a failed disk with an available disk in the system, proceed to the next step.

Click **Replace** on the **Disk Info** widget on the **Devices** screen for the disk you off-lined.

Select the new drive from the **Member Disk** dropdown list on the **Replacing disk** dialog.

{{< trueimage src="/images/SCALE/Storage/ReplacingDiskDialog.png" alt="Replacing Disk Dialog" id="Replacing Disk Dialog" >}}

4. Add the new disk to the existing VDEV. Click **Replace Disk** to add the new disk to the VDEV and bring it online.
Click **Replace Disk** to add the new disk to the VDEV and bring it online.

Disk replacement fails when the selected disk has partitions or data present.
To destroy any data on the replacement disk and allow the replacement to continue, select the **Force** option.
Disk replacement fails when the selected disk has partitions or data present.
To destroy any data on the replacement disk and allow the replacement to continue, select the **Force** option.

{{< trueimage src="/images/SCALE/Storage/ReplacingDiskStatusDialog.png" alt="Replacing Disk Status" id="Replacing Disk Status" >}}

When the disk wipe completes, TrueNAS starts replacing the failed disk.
TrueNAS resilvers the pool during the replacement process.
For pools with large amounts of data, this can take a long time.
When the resilver process completes, the pool status returns to **Online** status on the **Devices** screen.
When the disk wipe completes, TrueNAS starts replacing the failed disk.
TrueNAS resilvers the pool during the replacement process.
For pools with large amounts of data, this can take a long time.
When the resilver process completes, the pool status returns to **Online** on the **Devices** screen.

### Taking a Disk Offline
## Replacing a Failed Disk with a Hot Spare

We recommend users off-line a disk before starting the physical disk replacement.
Off-lining a disk removes the device from the pool and can prevent swap issues.
A **Hot Spare** vdev sets up drives as reserved to prevent larger pool and data loss scenarios.
TrueNAS automatically inserts an available hot spare into a **Data** vdev when an active drive fails.
TrueNAS resilvers the pool after the hot spare is activated.

{{< expand "Can I use a disk that is failing but still active?" "v" >}}
There are situations where you can leave a disk that has not completely failed online to provide additional redundancy during the replacement procedure.
{{< hint type=important >}}
We do not recommend leaving failed disks online unless you know the exact condition of the failing disk.
{{< /hint >}}
Attempting to replace a heavily degraded disk without off-lining it significantly slows down the replacement process.
{{< /expand >}}
To replace a disk in a pool with a hot spare:

{{< expand "The offline failed?" "v" >}}
If the off-line operation fails with a **Disk offline failed - no valid replicas** message, go to **Storage Dashboard** and click **Scrub** on the **ZFS Health** widget for the pool with the degraded disk. The **Scrub Pool** confirmation dialog opens. Select **Confirm** and then click **Start Scrub**.
1. [Take the disk offline](#taking-a-failed-disk-offline).
2. [Detach the failed disk](#detaching-a-failed-disk) to promote the hot spare.
3. Refresh the screen.
4. [Recreate the hot spare VDEV](#recreating-the-hot-spare).

{{< trueimage src="/images/SCALE/Storage/StorageZFSHealthScrub.png" alt="Storage ZFS Health Scrub Pool" id="Storage ZFS Health Scrub Pool" >}}
### Detaching a Failed Disk

When the scrub operation finishes, return to the **Devices** screen, click on the VDEV and then the disk, and try to off-line it again.
Go to the **Storage Dashboard** and click **Manage Devices** on the **Topology** widget for the degraded pool to open the **Devices** screen for that pool.
Click <span class="iconify" data-icon="mdi:keyboard-arrow-right"></span> next to the VDEV to expand it, then look for the disk with the **REMOVED** status.

{{< trueimage src="/images/SCALE/Storage/DevicesDiskDegradedHotSpare.png" alt="Devices Disk Failed - Hot Spare Active" id="Devices Disk Failed - Hot Spare Active" >}}

Click **Detach** on the **ZFS Info** widget on the **Devices** screen for the disk you off-lined.

Select **Confirm**, then click **Detach**.
TrueNAS detaches the disk from the pool and promotes the hot spare disk to a full member of the pool.

### Recreating the Hot Spare

After promoting the hot spare, recreate the **Spare** vdev and assign a disk to it.

{{< expand "Do I really need to promote the hot spare and then recreate the spare vdev?" "v" >}}
If you have a hot spare inserted into the pool and then follow the instructions in [Replacing a Failed Disk](#replacing-a-failed-disk), TrueNAS automatically returns the hot spare disk to the existing **Spare** vdev and **ONLINE** status.

However, we do not recommend this method, because it causes two resilver events: one when activating the hot spare and again when replacing the failed disk.
Resilvering degrades system performance until completed and causes unnecessary strain on the disk.

To avoid unnecessary resilvers, [promote the hot spare](#detaching-a-failed-disk) then recreate the hot spare vdev.
{{< /expand >}}

1. Click on **Manage Devices** to open the **Devices** screen, click anywhere on the VDEV to expand VDEV and show the drives in the VDEV.
If recreating the spare with a replacement in place of the failed disk, insert the replacement disk now.
The new disk must have the same or greater capacity as the failed disk.
If recreating the spare with an available disk in the system, proceed to the next step.

Go to the **Storage Dashboard** and click **Manage Devices** on the **Topology** widget for the degraded pool to open the **Devices** screen for that pool.

Click **Add VDEV** to open the **Add Vdevs to Pool** screen.

2. Click **Offline** on the **ZFS Info** widget. A confirmation dialog displays. Click **Confirm** and then **Offline**.
The system begins the process to take the disk offline. When complete, the disk displays the status of the failed disk as **Offline**.
The button toggles to **Online**.
Click the **Spare (Optional)** row to expand it.

{{< trueimage src="/images/SCALE/Storage/ReplaceDiskAndOnline.png" alt="Off-Lining A Disk" id="Off-Lining A Disk" >}}
{{< trueimage src="/images/SCALE/Storage/AddVdevToPoolSpareScreen.png" alt="Add Vdev Spare" id="Add Vdev Spare" >}}

3. You can physically remove the disk from the system when the disk status is **Offline**.
If the replacement disk is not already physically installed in the system, do it now.
Select a disk size equal to or greater than the failed disk or click **Manual Disk Selection** to choose the replacement disk.
Click **Save And Go To Review**.

Use **[Replace](#replacing-a-failed-disk)** to bring the new disk online in the same VDEV.
{{< trueimage src="/images/SCALE/Storage/AddVdevToPoolReviewScreen.png" alt="Review Screen" id="Review Screen" >}}

### Restoring the Hot Spare
Review changes then click **Update Pool**.
Select **Confirm**, then click **Continue**.

{{< include file="/static/includes/RestoreHotSpare.md" >}}
After completing the job, TrueNAS returns to the **Storage Dashboard** screen.
Review **Spare VDEVs** on the **Topology** widget to confirm the hot spare is added.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified static/images/SCALE/Storage/ReplacingDiskDialog.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
3 changes: 0 additions & 3 deletions static/includes/RestoreHotSpare.md

This file was deleted.

0 comments on commit d1454d5

Please sign in to comment.