0.10.0 (dh) beta (2017-11-01) *This version supports temperature and humidity sensors DH11, DH21, DH22
- Support of DS18B20 sensor is removed from this version
- IMPORTANT: if you are not going to use DHxx sensor or you need DS18b20 sensor then install version 0.8.9
- Info: not included in master branch. Look at 0.10-(DH) branch if you needed the code
0.8.9 (2017-06-08)
- Added option to select the type of external switch (mono- or bistable) on configuration screen
- Added option to publish relay status to Domoticz (authorization is not implemented yet)
- It's possible to request relay state by HTTP request http://ip-sonoff/?cmd=reportStatus
0.8.1 (2017-04-29)
- Defect fix: DS18B20 not launching
- Defect fix: Debugger flag was not saved
0.8.0 (2017-04-28)
- Added possibility to control Sonoff with HTTP protocol
- Added possibility to turn off Sonoff control by MQTT or HTTP protocol. Manual control is possible
- Changed the name of Exit link to Exit configuration
- MQTT comment to reboot Sonoff changed from reset to reboot
- Defect fix: Wrong error formating while upgrading sonoff with failure
- Defect fix: relay value not request each time when connection established to MQTT Broker
- Changed mechanism for WiFi and MQTT connection establishing. It increases Sonoff stability
- Couple of small UI changes
0.7.0 (2017-03-18)
- Added possibility to control sonoff with external switch
- Added option tu turn on/off serial debugger
- Fix defect related to host name broadcasting as an access point in local network
0.6.1 (2017-02-25)
- Device name is also set as host name in local network. (keep in mind not to use space while naming it)
0.6.0 (2017-02-24)
- Added possibility to define device name which is also used as WiFi SSID.
- Added option how Sonoff should behave after connection to MQTT is restored. Basically what should be the state of the relay when Sonoff connects to MQTT. Possible options: ON,OFF,Last known,Server value
- Possible options of relay behaviour after Sonoff power is restored changed to : ON,OFF,Last known
0.5.0 (2017-01-28)
- Configuration panel UI updated
- Added PL language
- Refactoring methods related to ds18b20 sensor
0.4.0 (2017-01-22)
- Added option how Sonoff should behave after power is restored. Basically what should be the state of relay when Sonoff powers up. Possible options: ON,OFF,Last known,Server value
- some code refactoring
0.3.2 (2017-01-15)
- changed how LED indicates entry to the Configuration panel
- some code refactoring
0.3.1 (2017-01-07)
- first release