23 changes: 19 additions & 4 deletions Specs/pr40084-11.md
Original file line number Diff line number Diff line change
Expand Up @@ -56,14 +56,29 @@ The default namespace OPC 40084-11 is not listed since all BrowseNames without p
|      CurrentState|0:LocalizedText|“Processing”||
|      Id|0:NodeId|ns=6;i=5026||
|||||
|    5:Drives|3:DrivesType||1), 4)|
|     0:NodeVersion|0:String|“1”|1)|
|||||
|    **5:ClampClosed**|0:Boolean|true||
|    **ExtruderEnabled**|0:Boolean|true||
|    **MouldId**|0:String|“Mould 42”||
|||||
|    5:Drives|3:DrivesType||1), 4)|
|     0:NodeVersion|0:String|“1”|1)|
|     **MainDrive_1**|3:DriveType|||
|     **Position**|0:String|“Main Drive”||
|     3:**ActualValue**|0:AnalogItemType -> 0:Double|40.5||
|      EURange|0:Range|Low: 0, High: 80||
|&ensp;&ensp;&ensp;&ensp;&ensp;&ensp;EngineeringUnits|0:EUInformation|<p>namespaceUri: “http://www.opcfoundation.org/UA/units/un/cefact”</p><p>unitId: 12888</p><p>displayName: “m/min”</p><p>description: “metre per minute”</p>||
|||||
|&ensp;&ensp;&ensp;5:TemperatureZones|4:ExtrusionTemperatureZonesType|||
|&ensp;&ensp;&ensp;&ensp;0:NodeVersion|0:String|“1”|1)|
|&ensp;&ensp;&ensp;-&ensp;**TemperatureZone_1**|4:ExtrusionTemperatureZoneType|||
|&ensp;&ensp;&ensp;&ensp;&ensp;**Id**|0:String|“Mould Temperature”||
|&ensp;&ensp;&ensp;&ensp;&ensp;IsPresent|0:Boolean|true|1)|
|&ensp;&ensp;&ensp;&ensp;&ensp;ControlMode|3:ControlModeEnumeration|0 (=AUTOMATIC)|1)|
|&ensp;&ensp;&ensp;&ensp;&ensp;**3:ActualValue**|0:AnalogItemType -> 0:Double|37.5||
|&ensp;&ensp;&ensp;&ensp;&ensp;&ensp;EURange|0:Range|Low: 0, High: 100||
|&ensp;&ensp;&ensp;&ensp;&ensp;&ensp;EngineeringUnits|0:EUInformation|<p>namespaceUri: “http://www.opcfoundation.org/UA/units/un/cefact”</p><p>unitId: 4408652</p><p>displayName: “°C”</p><p>description: “degree Celsius”</p>||

1) This variable is mandatory in the model but will not be displayed in the demonstrator
2) Not mandatory in OPC UA for Machinery but for this model and will be displayed in the demonstrator
2) Not mandatory in used specifications but for this model and will be displayed in the demonstrator
3) See <https://showcase.umati.org/Dashboard.html#location-of-fair-machine-and-software-icons-on-the-dashboard> for rules for filling the location.
4) Container object is mandatory in the model, but no instances inside (besides Variable NodeVersion) needed.
Binary file modified img/PlasticsRubber/PR_40084-11_PDF.pdf