Added valve opening and closing configuration for Sonoff TRVZB, v1.1.4 only #7130
Conversation
src/devices/sonoff.ts
Outdated
unit: '%', | ||
}), | ||
numeric({ | ||
name: 'valve_closing_degree(version >= v1.1.4)', |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Please move (version >= v1.1.4)
to the description
(same for valve_opening_degree
)
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Thanks for your reminding, it has been modified
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
The version of which component does this refer to exactly?
Hello, Do you think that the possibility of controlling the opening of the valve in percentage could be integrated into 1.1.5 version? Thank you |
Just to say that I have just tried to apply this locally and I have the error
which I think has been noted a few times in the 1.36.1 release thread so I don't think it is anything to do with this change but it is not working |
I thank you for your response and apologize for my messages which may be very approximate, as they are in automatic translation. I would like to be sure of your answer, if I have interpreted it correctly, you are explaining to me that whatever the future or past version it will not work with this thermostatic valve. I want to make sure, because I bought 8 of these thermostatic valves and I only have a short time to ask for a refund. If I am not mistaken about all of this, would you be kind enough to recommend one or more brands and models of thermostatic valves with which a maximum of read and write attributes are supported to control them, and especially the attribute to control the opening and closing of the thermostatic valve in degrees? Thank you so much. |
I have had these working great with 1.1.1 firmware and 1.36 Zigbee2MQTT. There is an issuewith the very latest release (is not affecting their actual usage) but I think it will be fixed quite quickly. I have had eight working fine for a few months |
Thank you. I myself find these thermostatic valves very good in terms of hardware and software and would like to focus on the Sonoff brand because its product range seems very developed, what do you think? But, it is essential for me the possibility of controlling the opening and closing of the thermostatic valve in percentage, because I want to use dedicated temperature sensors, and the "versatile_thermostat" plug-in in Home Assistant, what do you think? |
This is a discussion for a new feature to be added to Zigbee2MQTT so not really the right place for this discussion. I am using the Better Thermostat integration with there valves and external temperature sensors and they work well. If you want to discuss further I suggest creating a new discussion on the Zigbee2MQTT project |
Ok. Thank you very much. |
Hello,
Excuse me because I am not shure, can you confirme to me that I can command
the trv valve to opening and closing in % with Zigbee2Mqtt with this update?
Thank you.
Le mer. 17 avr. 2024, 05:13, lcheng33775823 ***@***.***> a
écrit :
… ***@***.**** commented on this pull request.
------------------------------
In src/devices/sonoff.ts
<#7130 (comment)>
:
> + numeric({
+ name: 'valve_opening_degree(version >= v1.1.4)',
+ cluster: 0xFC11,
+ attribute: {ID: 0x600B, type: 0x20},
+ description: 'Valve open position (percentage) control. ' +
+ 'If the opening degree is set to 100%, the valve is fully open when it is opened. ' +
+ 'If the opening degree is set to 0%, the valve is fully closed when it is opened, ' +
+ 'and the default value is 100%, ' +
+ 'The valve opening degree should be greater than or equal to the valve closing degree.',
+ valueMin: 0.0,
+ valueMax: 100.0,
+ valueStep: 1.0,
+ unit: '%',
+ }),
+ numeric({
+ name: 'valve_closing_degree(version >= v1.1.4)',
Thanks for your reminding, it has been modified
—
Reply to this email directly, view it on GitHub
<#7130 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/BHVOIURUVIKJULGRX6A6XJDY5XSGRAVCNFSM6AAAAABD5GX656VHI2DSMVQWIX3LMV43YUDVNRWFEZLROVSXG5CSMV3GSZLXHMZDAMBUHEZDINZTHE>
.
You are receiving this because you commented.Message ID:
***@***.***>
|
Thanks! |
I am getting errors if I want to set the valve position:
I am at dev branch (docker). |
No description provided.